ANALISIS HEAT TRANSFER COEFFICIENT SEBELUM DAN SESUDAH OVERHAUL PADA ECONOMIZER BOILER DI PT. JAPFA COMFEED BANJARMASIN Muhammad Ramlan; Aqli Mursadin
JTAM ROTARY Vol 1, No 1 (2019): JTAM ROTARY
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/jtam_rotary.v1i1.1395

Abstract

In some heat exchanger tools are widely used in industries such as power plants, oil refineries, chemical plants and petrochemicals, natural gas industry, refrigeration, and so forth. One example of a heat exchanger found in the poultry feed industry in PT.Japfa Comfeed Branch of Banjarmasin is the economizer, where the hot vapor of combustion in the furnace is used as a feed water heater before entering the boiler. From the results of the study known in the economize coefficient of the highest heat transfer before the overhaul of 1.393.1 Btu / jam.ft2.oF at 92.5 oC, and the lowest heat transfer coefficient before the overhaul of 1,334.8 Btu / jam.ft2. oF at 101 ° C. after the overhaul, it is known that the highest economizer heat transfer coefficient is 1,419.7 Btu / hour.ft2.oF at 99oC, and the lowest heat transfer coefficient after the overhaul is 1,378.6 Btu / hr.ft2.oF at 104.5 oC. The increase in heat transfer coefficient value after overhaul is 6.4% of the heat transfer coefficient before overhaul. Keywords: Economizer, Boiler,  Heat Transfer Coefficient
ANALISIS EFISIENSI KINARJA ECONOMIZER DI PT. PLN (PERSERO) KALIMANTAN SELATAN-TENGAH SEKTOR PLTU ASAM – ASAM Abdul Gapur; Aqli Mursadin
JTAM ROTARY Vol 1, No 1 (2019): JTAM ROTARY
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/jtam_rotary.v1i1.1402

Abstract

Electrical energy is the dominant energy needed for human life. One source of electricity income is Steam Power Plant (PLTU). With an installed capacity of     4 x65 MW for public transportation, each unit of acid acid plant has one boiler with 1 economizer as a means of boiler efficiency enhancer by absorbing hot flue gas. To avoid it then in need of maximum care to components of economizer. To see the effectiveness of the economizer it is necessary to observe the economizer. This study aims to analyze the effectiveness of the economizer. From the results of the boiler efficiency study from March 27, 2017 to April 10, 2017 with a total average efficiency in the analysis of 81.93%. With the highest efficiency on date On March 29, 2017 the efficiency calculated was 83.42% at 02:00. And the lowest on April 2, 2017, an 80.32% efficiency at 09:00. The factor that influences the efficiency ratio is the temperature difference between the incoming gas gas furnace (T_ (h, i)), exit (T_ (h, o)) and the feed water inlet tube temperature       (T_ (c, i)). The research obtained the highest heat transfer coefficient that is equal to 1.647,1 Btu/h.ft2 at 227,4°C on 27/03/2017 and the lowest that is equal to 1.636,91 Btu/h.ft2 at 233°C on 28/03/2017 Keywords: Economizer, Feed Water Tube, Flue Gas, Koefisien Heat Transfer, Heat transfer
ANALISIS KINERJA AIR HEATER DI PLTU ASAM-ASAM UNIT 2 Irawan Irawan; Aqli Mursadin
JTAM ROTARY Vol 1, No 1 (2019): JTAM ROTARY
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/jtam_rotary.v1i1.1396

Abstract

Indonesia as one of the largest coal producers utilizes this advantage by establishing a steam power plant, one of which is Borneo south PLTU power plant PT.PLN (persero) south of Borneo and Central Borneo Asam-Asam generation sector. One important component of PLTU is air heater to raise the combustion air temperature. Initial heating of ljungstrom type lattest regenerative air  heater in PLTU Asam-Asam unit 2 is carried out cleaning and maintenance on seal and gas side surfaces to optimize heat transfer coefficient and ratio of air intake ratio exposed by forced draft fan and air heated by flue gas in heater air heater elements and transferred to the combustion chamber to make efficient use of new fuel. Measurements were carried out on August 9, 2017 for 2 hours to find out the average value of heat transfer coefficient and temperature comparison of entry and exit from air heater of Asam-Asam unit 2 steam power plant. This research was conducted to find out the value of heat transfer coefficient and air temperature ratio with measurement on the inlet and outlet for two hours. The results of the air heater performance analysis in in PLTU Asam-Asam unit 2 steam power plant in terms of the highest heat transfer coefficient was 62.75 W/m^2.℃ at 2:04 PM, while the lowest heat transfer coefficient was 62.37 W/m^2.℃ at 3:10 PM, and the average heat transfer coefficient is 62.50 W/m^2.℃ . While the highest water heater ratio 9.70 at 3:44 PM and the lowest ratio 8.32 at minute 3:09 PM, and the average water heater ratio 9.01. Heater water heater elements in good condition and performance in receiving and releasing heat. Keywords: Air Heater,  Heat Transfer Coefficient, Temperature Ratio,  Heating  Elements