PENGARUH JUMLAH LILITAN KUMPARAN STATOR TERHADAP KINERJA GENERATOR MAGNTE PERMANEN FLUKS AKSIAL SATU FASA Agus Nur Hidayat; Suyitno; Daryanto
Journal of Electrical Vocational Education and Technology Vol 2 No 2 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0022.06

Abstract

The purpose of this research is to know to know the influence of stator coil shape to performance (induced voltage and output power) of single phase axial flux permanent magnet generator. The method used is an experimental method. The population in this study is a unit of single phase axial flux permanent magnet generator. The sample in this study is the stator coil. Experiments were carried out by testing the performance of a single-phase axial flux permanent magnet generator in each variation the number of coil windings which had the 90 turns, 120 turns, and 350 turns. Experiments were carried out with no -load testing and with a resitive load that used 30 Watt incandescent lamps. The conclusion of this study shows that there is an influence from the number of coil windings on the performance (induced voltage and output power) of the generator. From three variations of the stator coil that used as sample, the highest performance is shown by the single phase axial flux permanent magnet generator which used the highest number of coil stator turns. The more number of turns, the better the performance of a single-phase axial flux permanent magnet generator. Abstrak Tujuan dari penelitian ini adalah untuk mengetahui pengaruh jumlah lilitan kumparan stator terhadap kinerja generator fluks aksial satu fasa yang berupa tegangan induksi dan daya listrik yang dihasilkan. Metode yang digunakan adalah metode eksperimen. Populasi pada penelitian ini ialah satu unit generator magnet permanen fluks aksial satu fasa. Sampel pada penelitian ini ialah kumparan stator. Eksperimen dilakukan dengan menguji kinerja generator magnet permanen fluks aksial satu fasa pada setiap variasi jumlah lilitan kumparan stator 90 lilitan, 120 lilitan, dan 350 lilitan. Ekperimen dilakukan dengan pengujian tanpa beban dan dengan beban resitif berupa lampu pijar 30 Watt. Kesimpulan pada penelitian ini menunjukkan bahwa adanya pengaruh jumlah lilitan kumparan stator terhadap kinerja generator yang berupa tegangan induksi dan daya listrik keluaran. Dari ketiga variasi sampel kumparan stator, kinerja tertinggi ditunjukkan oleh generator magnet permanen fluks aksial satu fasa yang menggunakan jumlah lilitan kumparan stator terbanyak. Semakin banyak jumlah lilitan, semakin baik kinerja generator magnet permanen fluks aksial satu fasa.
PENGARUH DIMENSI MAGNET PERMANEN NdFeB DAN JARAK CELAH UDARA TERHADAP KINERJA GENERATOR MAGNET PERMANEN FLUKS AKSIAL SATU FASA Bangun Giri Pamungkas; Suyitno; Daryanto; Perdamean Sebayang
Journal of Electrical Vocational Education and Technology Vol 2 No 2 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0022.07

Abstract

The purpose of this research is to know the influence of NdFeB permanent magnet dimensions and the distance of air gap on performance of single phase axial flux permanent magnet generator. In this research using quantitative approach with experimental method. Research subjects used, namely permanent magnetic generator axial flux with two rotor samples that have different magnetic dimensions and conducted air gap variation. The research data was collected by testing without load and testing with electrical load, to know the performance values of the generator in the form of induction voltage and electric power. The results showed that the induction voltage and electric power were affected by the magnetic dimensions and the distance of the air gap. These results indicate that the rotor with a magnetic surface area of 0.0058 m2 and 0.0034 m2 produces an induced voltage of 91.7 and 27.1 V, as well as a power of 14 and 2.8 W. Whereas, for variations in the air gap with the rotor magnetic surface area 0.0058 m2 and varied 2; 3; 4; 5; and 6 mm produces an induced voltage of 91.7; 89.0; 86.5; 80.2; and 68.5 V, and power of 14; 12; 10.9; 10.5; and 8.8 W. Thus, the use of a magnet ic dimension that is larger and in accordance with the size of the coil, as well as the use of a small air gap distance will result in a better induction voltage value. Abstrak Tujuan dari penelitian ini adalah untuk mengetahui pengaruh dimensi magnet permanen NdFeB dan jarak celah udara terhadap kinerja generator magnet permanen fluks aksial satu fasa. Pada penelitian ini menggunakan pendekatan kuantitatif dengan metode eksperimen. Subjek penelitian yang digunakan, yaitu generator magnet permanen fluks aksial dengan dua sampel rotor yang memiliki dimensi magnet berbeda dan dilakukan variasi celah udara. Pengumpulan data penelitian dilakukan dengan pengujian tanpa beban dan pengujian dengan beban listrik, untuk mengetahui nilai-nilai kinerja generator berupa tegangan induksi dan daya listriknya. Hasil penelitian menunjukkan bahwa tegangan induksi dan daya listrik dipengaruh oleh dimensi magnet dan jarak celah udara. Hasil tersebut menunjukkan bahwa pada rotor dengan luas permukaan magnet 0,0058 m2 dan 0,0034 m2 menghasilkan tegangan induksi sebesar 91,7 dan 27,1 V, serta daya sebesar 14 dan 2,8 W. Sedangkan, pada variasi celah udara dengan rotor luas permukaan magnet 0,0058 m2 dan divariasi 2; 3; 4; 5; dan 6 mm menghasilkan tegangan induksi sebesar 91.7; 89.0; 86.5; 80.2; dan 68.5 V, serta daya sebe sar 14; 12; 10,9; 10,5; dan 8,8 W. Maka, penggunaan dimensi magnet yang lebih besar dan sesuai dengan ukuran kumparan, serta penggunaan jarak celah udara yang kecil akan menghasilkan nilai tegangan induksi yang lebih baik.
RANCANG BANGUN TURBIN UAP PADA MAKET PEMBANGKIT LISTRIK TENAGA UAP Muhamad Rizky Septianto; Massus Subekti; Daryanto
Journal of Electrical Vocational Education and Technology Vol 2 No 2 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0022.08

Abstract

The purpose of this study was to produce a prototype steam turbine at maket power plant steam generator torque that can play. The research method used in this research is descriptive analysis by type of engineering. Steam turbine is a Primemover that converts potential energy into mechanical energy in the form of rotation of the turbine shaft. Steam turbine constructed dimensions turbine type used single stage impulse turbine, turbine disc diameter of 33mm, the amount of movement of the blade 30 pieces, the distance between the blade 14,6mm, radious 2,63mm blade, the type of nozzle used convergent, area 3,2cm2 neck cross-section, the cross sectional area of 3,2cm2 side exit. Mockups of the steam turbine can generate 1490 rpm for turbine with a steam generator at a pressure of 4 kg/cm2 using a water volume of 19 liters. Maximum pressure that can be accepted by the steam turbine is 8 kg/cm2 with 11.000rpm, produced according to the process of heating boiler which is the maximum vapor pressure of 8kg/cm2 at a temperature of 1700C. and and be able to turn a generator with a torque of 4.6 Nm with a pressure of 8 kg/cm2 The conclusion of this study is the turbine can be built through the calculations have been carried out and taking into account the performance of the boiler and steam generator.Turbin built to produce 1336.6 rpm to spin the turbine without the steam generator at a pressure of 2 kg / cm2. Steam turbines are built to produce 1408 rpm, and generates a voltage 140.8 volts, and be able to play generatoe torque of 0.6 Nm for turbine with the steam generator at a pressure of 4 kg / cm2. Maximum pressure received by the steam turbine is 8 kg / cm2 at 10 453 rpm for the turbine without a generator, and a voltage of 271.8 volts produces, as well as being able to roll generatoe torque of 0.9 Nm for turbine with a generator on the vapor pressure of the incoming sebesae 8 kg / cm2. Abstrak Tujuan dari penelitian ini adalah untuk menghasilkan prototipe turbin uap yang mampu memutar torsi generator. Metode penelitian yang dipakai dalam penelitian ini adalah analisis deskriptif dengan jenis rekayasa teknik. Turbin uap (steam turbine) adalah penggerak mula yang merubah energi potensial menjadi energi mekanis dalam bentuk putaran poros turbin. Turbin uap yang dibangun memiliki dimensi jenis turbin yang digunakan turbin impuls single stage, cakram turbin berdiameter 33 mm, jumlah sudu gerak 30 buah, jarak bagi antar sudu 14,6mm, jari–jari sudu 2,63mm, jenis nosel yang digunakan konvergen, luas penampang leher 3,2cm2, luas penampang sisi keluar 3,2cm2. Maket turbin uap tersebut dapat menghasilkan 1490 rpm untuk putaran turbin dengan generator pada tekanan uap 4 kg/cm2 menggunakan volume air 19 liter. Tekanan maksimal yang mampun diterima oleh turbin uap ini adalah 8 kg/cm2 dengan 11.000rpm, sesuai yang dihasilkan pada proses memanasan boiler yaitu tekanan uap maksimalnya adalah 8kg/cm2 pada suhu 170oC. serta mampu memutar generator dengan torsi 4,6 N dengan tekanan 8 kg/cm2. Kesimpulan dalam penelitian ini adalah turbin dapat dibangun melalui perhitungan yang telah dilakukan dan dengan mempertimbangkan unjuk kerja antara boiler dan generator.Turbin uap yang dibangun dapat menghasilkan 1336,6 rpm untuk putaran turbin tanpa generator pada tekanan uap 2 kg/cm2. Turbin uap yang dibangun dapat menghasilkan 1408 rpm, dan menghasilkan tegangan 140,8 volt, serta mampu memutar torsi generatoe sebesar 0,6 Nm untuk putaran turbin dengan generator pada tekanan uap 4 kg/cm2. Tekanan maksimal yang diterima oleh turbin uap ini adalah 8 kg/cm2 dengan 10.453 rpm untuk putaran turbin tanpa generator, dan menghasilkan tegangan 271,8 volt, serta mampu memutar torsi generatoe sebesar 0,9 Nm untuk putaran turbin dengan generator pada tekanan uap yang masuk sebesae 8 kg/cm2.
EVALUASI SISTEM PENANGKAL PETIR PADA GEDUNG PERKULIAHAN (Studi pada Universitas Negeri Jakarta Kampus A Sektor C) Prima Prayeni; Parjiman; Daryanto
Journal of Electrical Vocational Education and Technology Vol 2 No 2 (2017): Journal Of Electrical Vocational Education and Technology
Publisher : Fakultas Teknik Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JEVET.0022.09

Abstract

The purpose of this study is to determine the suitability of lightning protection system in University State of Jakarta campus A sector C with PUIPP 1983, the minister of labor legislation of the republic of Indonesia PER.02/MEN/1989, and SNI 03-7015-2004, based the importance of the lightning protector system. Method that used is evaluation description method. In collecting data, the main components of the lightning rod installation are observed, measuring earth resistance, and conducting connectivity tests if the channeling down is not visible, the data can then be processed mathematically which then compares the results with PUIPP 1983, regulation of the minister of labor of the Republic of Indonesia PER. 02 / MEN / 1989, and SNI 03-7015- 2004. Results of evaluation lightning protector system research showed that only Ki Hajar Dewantara building that obey with PUIPP 1983, the minister of labor legislation of the republic of Indonesia 02/MEN/1989, and SNI 03-7015-2004. The other buildings not obey with PUIPP 1983, the minister of labor legislation of the republic of Indonesia PER.02/MEN/1989, and SNI 03-7015-2004, caused main 195nticipat of lightning protection in these building is lost, broken, or the plan of lightning protector not macht with protection area needed. In other case few buildings of unj kampus A sector C that unprotected, the buildings are DE, E, F, L, L5 and K FIS. This things must be 195nticipate with add one active lightning protector at K FIS building with minimum radius 107,47m. Of course with notes to evaluate periodically especially if there is construction in the building on radius protection lightning protection system enhancements. Abstrak Tujuan penelitian ini adalah untuk mengetahui kesesuaian sistem penangkal petir Universitas Negeri Jakarta kampus A sektor C dengan PUIPP 1983, peraturan menteri tenaga kerja Republik Indonesia PER.02/MEN/1989, dan SNI 03-7015-2004, didasari pada pentingnya sistem penangkal petir. Metode yang digunakan adalah metode evaluasi deskriptif. Pada pengumpulan data, dilakukan observasi komponen utama instalasi penangkal petir, mengukur tahanan pentanahan, dan melakukan uji konektivitas apabila penyalur turun tidak terlihat, data yang di dapat lalu diolah secara matematis yang kemudian dibandingkan hasilnya dengan PUIPP 1983, peraturan menteri tenaga kerja Republik Indonesia PER.02/MEN/1989, dan SNI 03-7015-2004. Hasil penelitian evaluasi sistem penangkal petir eksternal menunjukkan hanya satu gedung pada UNJ kampus A sektor C instalasinya telah memenuhi dan sesuai dengan PUIPP 1983, peraturan menteri tenaga kerja Republik Indonesia PER.02/MEN/1989, dan SNI 03-7015-2004. Sedangkan, gedung lainnya belum memenuhi PUIPP 1983, peraturan menteri tenaga kerja Republik Indonesia PER.02/MEN/1989, dan SNI 03-7015-2004, hal ini dikarenakan pada gedung lainnya banyaknya komponen instalasi penangkal petir yang sudah tidak lengkap, rusak, serta perencanaan instalasi yang tidak sesuai dengan kebutuhan gedung. Selain itu terdapat beberapa wilayah UNJ kampus A sektor C yang belum terlindungi, diantaranya adalah Gedung DE, E, F, L, L5 dan K FIS. Hal ini dapat diantisipasi dengan menambah penangkal petir jenis aktif diatas gedung K FIS dengan radius minimal 107,47m. Tentunya dengan catatan melakukan evaluasi secara berkala, terlebih apabila terdapat pembangunan pada gedung yang berada pada radius perlindungan sistem penangkal petir tambahan.