Dila Nelvo Dasril
Universitas Baiturrahmah

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Pengukuran Dosis Eksternal Yang Diterima Oleh Mahasiswa Praktikum Teknik Radiografi di Laboratorium Radiologi Universitas Baiturrahmah Padang Dila Nelvo Dasril; Oktavia Puspita Sari
Jurnal Teori dan Aplikasi Fisika Vol 8, No 1 (2020): Jurnal Teori dan Aplikasi Fisika
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jtaf.v8i1.2318

Abstract

The utilization of ionizing radiation in the form of X-rays in addition to providing benefits to the medical world also has the potential to have a detrimental effect on workers, patients and, society. Radiation protection is a very important aspect of controlling this adverse effect. Every utilization of ionizing radiation must have endeavored so that the reception of radiation doses by radiation workers is always as low as possible so that the prescribed dose limit (NBD) value is not exceeded. NBD for apprentices and students who are as low as 18 years old, who are carrying out training or practical work, or who because of their educational needs are forced to use a source of ionizing radiation, the same as the NBD that applies to radiation workers. Dose limit values for radiation workers must not exceed 20 mSv (twenty millisieverts) per year on average for five consecutive years. Determination of the external radiation dose received by practicum students at the Baiturrahmah University Radiology Laboratory aims to calculate how much the external radiation dose received by students during carrying out one course. Based on the results of the study found that the measurement of external radiation dose received by the student is 0 or there is no scattering radiation received by students, this is because at the time of exposure they are in the correct position that is behind the control panel wall that has been coated with Lead (Pb).
Uji Efektifitas Dinding Ruangan Panoramik Instalasi Radiologi RSUD Prof. Dr. MA Hanafiah SM Batusangkar Menggunakan TLD-100 Dila Nelvo Dasril; Nerifa Dewilza
Physics Education Research Journal Vol 2, No 2 (2020)
Publisher : Faculty of Science and Education, UIN Walisongo Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21580/perj.2020.2.2.5087

Abstract

Research on the effectiveness of panoramic room walls has been carried out in the Radiology Installation of Prof. Dr. MA Hanafiah SM Batusangkar. This study aims to determine the effectiveness of the panoramic room walls in absorbing radiation emitted by panoramic aircraft, as well as knowing the safety level of the room around the panoramic inspection room in accordance with the dose limit values of workers and the general public. This type of research is a quantitative research by taking direct measurements. The research was conducted by measuring the radiation dose at six points of the panoramic room wall using a radiation measuring instrument, namely TLD-100. The results showed that the effectiveness of the walls was only able to absorb radiation less than 90%, with the shield category on the walls that was not good enough to withstand radiation. Therefore, it is necessary to renovate the panoramic room walls in accordance with safety standards.