Claim Missing Document
Check
Articles

Found 2 Documents
Search

ANALYSIS OF SAFETY SYSTEM RELIABILITY KI HADJAR DEWANTARA MAKO KODICLATAL BUILDING TOWARDS FIRE HAZARDS PREVENTION Dodiek Alfianzi; Ikhwan Syahtaria; Udisubakti Cipto Mulyono; I Made Jiwa Astika
JOURNAL ASRO Vol 12 No 02 (2021): International Journal of ASRO
Publisher : Indonesian Naval Technology College - Sekolah Tinggi Teknologi Angkatan Laut - STTAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37875/asro.v12i02.397

Abstract

Designing a fire prevention inspection system in buildings is very necessary, to determine the level of reliability. The fire prevention management system uses the following criteria: precautionary measures and preventive supervision against fire hazards. The assessment of the system design is carried out by means of a questionnaire for respondents who understand / are experts in fire problems, and the application of the system design uses direct surveys and questionnaires to the building manager. The assessment is carried out at the smallest level. Analysis of the building reliability inspection system in fire prevention using the Analytical Hierarchy Process (AHP) method, the criteria used are: prevention, limitation and extinguishing against fire. The fire prevention management system uses the following criteria: precautionary measures and preventive supervision against fire hazards. The results of the reliability inspection of the Ki Hadjar Dewantara Mako Kodiklatal building in Surabaya with a value of 94.06% indicated that the reliability system was in the "Less Reliable" category for fire hazard prevention. Keywords: Inspection, fire prevention, reliability.
ANALYSIS OF THE RELIABILITY OF THE BUILDING SAFETY SYSTEM IN KI HADJAR DEWANTARA KODIKLATAL BUILDING ON FIRE HAZARDS PREVENTION Dodiek Alfianzi; Avando Bastari; Okol Sri Suharyo
STTAL POSTGRADUATE - INTERNATIONAL CONFERENCE Vol 4 No 1 (2020): Indonesia Naval Technology College STTAL Postgraduate International Conference -
Publisher : Indonesian Naval Technology College STTAL

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRACT This study aims to determine the reliability value of the fire system and the safety of the KI Hadjar Dewantara building in the case of a fire. This research questionnaire was conducted twice. The Analytical Hierarchy Process (AHP) method will be applied to the first questionnaire to obtain the weighting of the fire variables which includes site completeness, rescue facilities, passive protection systems, and active protection systems. The second questionnaire used the check-list method based on the Minister of Public Works Regulation Number 26 of 2008 to determine the reliability value of the building in the event of a fire. The results for the reliability value of the Ki Hadjar Dewantara building from Mako Kodiklatal using the AHP method and the check-list respectively are as follows: 91.93% and 91.45%. So, it can be concluded that the building security system in case of a fire is in “Good” condition. Keywords: Fire, Reliability, AHP