Claim Missing Document
Check
Articles

Found 6 Documents
Search

PENURUNAN KADAR KOLESTEROL TOTAL DAN TRIGLISERIDA DENGAN TEKNIK BEKAM PADA PENDERITA HIPERKOLESTEROLEMIA Hendra Budi Sungkawa
Meditory : The Journal of Medical Laboratory Vol 7, No 1 (2019): Meditory, volume 7 , nomer 1 , Juni 2019
Publisher : Jurusan Analisis Kesehatan, Poltekkes Kemenkes Denpasar

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (322.657 KB) | DOI: 10.33992/m.v7i1.460

Abstract

Background : Cupping is one type of natural treatment by suctioning the skin, cutting and removing blood from the skin surface. Cupping works for various diseases, can cure acute, chronic and degenerative diseases, such as high blood pressure and hypercholesterolemia. Cupping therapy has been carried out since thousands of years BC. Cupping consists of dry cupping and wet cupping.Method : This study used a pre-experimental design method for the One Group Pre test Post test.  The examination method for Total cholesterol and Triglyceride levels was carried out using the CHOD - PAP (Cholesterol Oxydase Para Amino Phenazone) method and GPO - PAP (Glycerol-3-Phosphate Oxydase Para Amino Phenazone). Data were analyzed by T-Test.Result : Total cholesterol levels before wet cupping 231 mg / dl and after wet cupping therapy 220 mg / dl (p = 0.000) (r = 0.803) and Triglyceride levels before wet cupping 184 mg / dl and after wet cupping therapy 159 mg / dl (p = 0,000) (r = 0.901). There is a relationship between wet cupping therapy with a decrease in Total Cholesterol and Triglycerides in hypercholesterolemic patients in the working area of the Pinyuh River Inpatient Health Center.Conclusion : For the development of science it is recommended that further research be conducted on the effects of wet cupping therapy on clinical chemical parameters such as creatinine, gout, blood glucose levels, and other blood parameters.
PENENTUAN NILAI RUJUKAN HEMOGLOBIN PADA MASYARAKAT KALBAR Hendra Budi Sungkawa; wahdaniah wahdaniah
Jurnal Vokasi Kesehatan Vol 6, No 1 (2020): Januari 2020
Publisher : Poltekkes Kemenkes Pontianak

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (231.061 KB) | DOI: 10.30602/jvk.v6i1.441

Abstract

Nilai rujukan hasil pemeriksaan laboratorium biasanya berupa nilai rentang yang digunakan dokter untuk menginterprestasikan hasil dan mengambil keuntungan klinik yang menentukan tindak lanjut terhadap pasien. Nilai normal hemoglobin untuk seseorang sukar ditentukan dikarenakan setiap suku bangsa memiliki kadar hemoglobin yang bervariasi. Namun kadar hemoglobin telah ditetapkan oleh WHO berdasarkan umur dan jenis kelamin.Penelitian ini bertujuan untuk mengetahui gambaran kadar hemoglobin masyarakat di wilayah Kalimantan Barat berdasarkan kelompok umur dan jenis kelamin. Tujuan khusus yang ingin dicapai dari penelitian ini adalah menetapkan nilai rentang normal hasil pemeriksaan hemoglobin di Kalimantan Barat.Desain yang digunakan dalam penelitian ini yaitu metode observasional analitik yang bersifat potong lintang (Cross Sectional). Pemeriksaan kadar hemoglobin dilakukan menggunakan Hematology Analyzer sebanyak 1456 sampel dari 6 kabupaten / kota di Kalimantan Barat.Hasil penelitian menunjukkan bahwa ada perbedaan hasil penelitian dengan rujukan WHO  dengan nilai p < 0,005. Ditetapkan kadar hemoglobin pada masyarakat Kalimantan Barat untuk kategori umur 6 bulan – 6 tahun yaitu 9,4 g/dl – 13,64 g/dl, 6 tahun – 14 tahun yaitu 9,92 g/dl – 14,79 g/dl, dewasa laki-laki yaitu 12,15 g/dl – 17,20 g/dl dan dewasa perempuan yaitu 9,97 g/dl – 15,00 g/dl
Validasi Spektrofotometer UV-VIS pada Analisis Formalin Di Poltekkes Kemenkes Pontianak Hendra Budi Sungkawa; Anjas Awi Ladika
Jurnal Laboratorium Khatulistiwa Vol 2, No 2 (2019): Mei 2019
Publisher : poltekkes kemenkes pontianak

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30602/jlk.v2i2.332

Abstract

Abstract: Validation is the process of determine a method, an instrument and a technician to fulfl the requirements for testing. Validation of the instrument needs to be done separately. The UV-VIS spectrophotometer in Poltekkes Kemenkes Pontianak has many advantages such as wave length 190 - 1100 nm, using double beam optical system, has 2 nm spectrum bandwidth, but the using of the instrument has not been maximized. It is necessary to validate the UV-VIS spectrophotometer. The aim of this research is to determine the precision, accuracy, linearity, Limit of Detection (LOD) and Limit of Quantifcation (LOQ) on UV-VIS spectrofotometer on formalin analysis at Poltekkes Kemenkes Pontianak. The research uses pre-experimental design and purposive sampling method with formalin standard as population. The sample used is formalin standard with various concentration 0 ppm, 1 ppm, 2 ppm, 3 ppm, 4 ppm and 5 ppm with nine replication. Samples reacted with chromatophore acid, the purple color showed the sample containing formalin, then absorbance value measured to obtain formalin content in the sample. The result of precision value 94.43%, accuracy value 97.77%, linearity test in the concentration range 0-10 ppm gives correlation coeffcient value r = 0.918 with the limit of detection (LOD) of the formalin is 4.98 ppm and the limit of quantifcation (LOQ) of the formalin is 16.60 ppm. Based on the result of the research that it can be concluded that UV-VIS spectrophotometer on formalin analysis in Poltekkes Kemenkes Pontianak well validated because of the fulfllment of fve validation parameter criteria.Abstrak: Validasi adalah proses untuk memastikan apakah suatu metode, alat dan teknisi memenuhi persyaratan untuk pengujian. Validasi alat perlu dilakukan tersendiri. Spektrofotometer UV-VIS yang ada di Poltekkes Kemenkes Pontianak memiliki banyak kelebihan diantaranya rentang gelombang yang lebih lebar 190 – 1100 nm, menggunakan sistem optik double beam, memiliki bandwidth spektrum 2 nm, namun penggunaannya belum maksimal. Maka perlu dilakukan validasi terhadap spektrofotometer UV-VIS tersebut. Tujuan penelitian ini untuk mengetahui presisi, akurasi, linearitas, batas deteksi (LOD) dan batas kuantitasi (LOQ) pada Spektrofotometer uv-vis pada analisis formalin di Poltekkes Kemenkes Pontianak. Penelitian ini menggunakan desain pre-experimental metode purposive sampling dengan populasi standar formalin. Sampel yang digunakan yaitu standar formalin dengan berbagai konsentrasi 0 ppm , 1 ppm, 2 ppm, 3 ppm, 4 ppm dan 5 ppm dengan pengulangan sebanyak sembilan kali. Sampel direaksikan dengan asam kromatofat, perubahan warna menjadi ungu menunjukkan sampel mengandung formalin, kemudian diukur nilai absorbansinya untuk mendapatkan kadar formalin dalam sampel. Hasil penelitian nilai presisi 94.43%, nilai akurasi 97.77%, uji linearitas pada rentang konsentrasi 0 – 10 ppm memberikan nilai koefsien korelasi r = 0.918 dengan batas deteksi (LOD) formalin 4.98 ppm dan batas kuantitasi (LOQ) 16.60 ppm. Berdasarkan hasil penelitian dapat disimpulkan bahwa spektrofotometer UV-VIS pada analisis formalin di Poltekkes Kemenkes Pontianak tervalidasi dengan baik karena terpenuhinya kriteria lima parameter validasi.
Perbedaan Kadar Asam Lemak Bebas Pada Minyak Goreng Yang Mengalami Pemanasan Ulang Dengan Penambahan Bawang Merah (Allium Cepa) Dan Bawang Putih (Allium Sativum) Gervacia Jenny Ratnawati; Hendra Budi Sungkawa
Jurnal Laboratorium Khatulistiwa Vol 1, No 2 (2018): Mei 2018
Publisher : poltekkes kemenkes pontianak

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30602/jlk.v1i2.146

Abstract

Abstract: Cooking oil generally can be used for 3-4 times frying. If it used repeatedly, oil will be changed in color. When frying process, double bonds in unsaturated fatty acids will break and formed saturated fatty acids. A qualified oil was contained unsaturated fatty acid more than its saturated fatty acids. The use of oil many times will lead the oil double bond oxidized and form the peroxide group and cyclic monomer, such oil reported damage and harm our health. A higher temperature and a longer time of heating, saturated fatty acids level will be increased. Beside repeatedly frying, oil can be damaged by wrong storage for certain period, consequently triglyceride bond broke and form into glycerol and free fatty acids (FFA). Red onion and garlic contain high antioxidant. The benefits that make them become phenomenal in medical research is their potency in against cancer and other dangerous diseases. They also can be used as crucial antioxidant sources in the fight against free radicals in body. Based on study results showed that the average of free fatty acids (FFA) in used cooking oil that added by garlic was 5,29% and red onion was 5,22%. Statistical test gained by computerized data processing with t-test p value>0,05 so it can be concluded that Ha refused by meaning that there was not a difference between number of FFA in used cooking oil which added garlic and red onion. Abstrak: Minyak goreng biasanya bisa digunakan hingga 3 - 4 kali penggorengan. Jika digunakan berulang kali, minyak akan berubah warna. Saat penggorengan dilakukan, ikatan rangkap yang terdapat pada asam lemak tak jenuh akan putus membentuk asam lemak jenuh. Minyak yang baik adalah minyak yang mengandung asam lemak tak jenuh yang lebih banyak dibandingkan dengan kandungan asam lemak jenuhnya.  Penggunaan minyak berkali-kali akan membuat ikatan rangkap minyak teroksidasi membentuk gugus peroksida dan monomer siklik, minyak yang seperti ini dikatakan telah rusak dan berbahaya bagi kesehatan.  Suhu yang semakin tinggi dan semakin lama pemanasan, kadar asam lemak jenuh akan semakin naik. Selain karena penggorengan berkali-kali, minyak dapat menjadi rusak karena penyimpanan yang salah dalam jangka waktu tertentu sehingga ikatan  trigliserida pecah menjadi gliserol dan asam lemak bebas. Bawang merah dan bawang putih sangat tinggi akan kandungan antioksidannya. Manfaat bawang merah dan bawang putih yang membuatnya fenomenal di dunia medis adalah kemampuannya dalam memerangi kanker dan berbagai penyakit berbahaya. Ia juga dapat dijadikan sumber antioksidan yang sangat ampuh untuk memerangi radikal bebas di dalam tubuh. Berdasarkan hasil penelitian diperoleh kadar rata-rata kadar asam lemak bebas pada minyak goreng bekas yang ditambahkan bawang putih sebesar 5,29% dan bawang merah sebesar 5,22%. Hasil uji statistic diperoleh pengolahan data secara komputerisasi melalui uji-t  diperoleh nilai p > 0,05, sehingga dapat disimpulkan bahwa Ha ditolak yang artinya tidak terdapat perbedaan kadar bilangan asam lemak bebas pada minyak goreng bekas yang ditambahkan bawang putih dan bawang merah.
Hubungan Tingkat Pengetahuan dengan Presisi dan Akurasi Pemipetan Menggunakan Mikropipet Metode Forward Hendra Budi Sungkawa; Inten Ayu Kusuma
Jurnal Laboratorium Khatulistiwa Vol 2, No 1 (2018): November 2018
Publisher : poltekkes kemenkes pontianak

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30602/jlk.v2i1.318

Abstract

Abstract : Pipetting is one of the most important activities in health laboratory analysis. Knowledge of pipetting must be owned by every health laboratory. Students of health analyst as a candidate of health laboratory who will become medical support service unit is expected to be able to do the pipetting precision and accurately. To get a thorough and accurate results then the results of the analysis must be located within a specifc control area and both in precision and accuracy. Precision and accuracy are responsible for analytical interpretation of test results and testing procedures. The method use in this research is the forward method by 61 people research samples which determined by simple random sampling. While the research design used was observational analytics. Based on the results of the research obtained the level of knowledge of respondents research is 71,38; precision pipetting 99,69% and accuracy pipetting 99,58%. From the data that has been obtained then analyzed statistically using tau kendau test. The result indicates that the level of knowledge and precision has a p=0,640 and correlation coeffcient of -0,044 so that the Ho is accepted, meaning there is no relationship between the level of knowledge and precision meaningful. Meanwhile, the level of knowledge and accuracy of the p=0,574 and correlation coeffcient value is -0,053 so that Ho is accepted, it means there is no relationship between the level of knowledge with accuracy. Abstrak: Pemipetan merupakan salah satu kegiatan yang sangat penting dalam analisa laboratorium kesehatan. Pengetahuan pemipetan harus dimiliki oleh setiap tenaga laboratorium kesehatan. Mahasiswa analis kesehatan sebagai calon tenaga laboratorium kesehatan yang akan menjadi unit pelayanan penunjang medis diharapkan mampu melakukan pemipetan dengan teliti dan akurat. Untuk mendapatkan hasil yang teliti dan akurat maka hasil analisa harus terletak di dalam daerah kontrol tertentu dan baik dalam presisi maupun akurasi. Presisi dan akurasi bertanggung jawab terhadap interpretasi analitik hasil pengujian serta prosedur pengujian. Metode yang dilakukan dalam penelitian ini adalah metode forward oleh sampel penelitian sebanyak 61 orang yang ditentukan secara simple random sampling. Sedangkan desain penelitian yang digunakan adalah observasional analitik. Berdasarkan dari hasil penelitian diperoleh nilai tingkat pengetahuan responden penelitian adalah 71,38; presisi pemipetan 99,69% dan akurasi pemipetannya 99,58%. Dari data yang telah didapatkan kemudian dianalisis secara statistik menggunakan uji kendal tau. Untuk tingkat pengetahuan dengan presisi didapatkan hasil nilai p=0,640 dan koefsien korelasi -0,044 sehingga Ho diterima, berarti tidak ada hubungan antara tingkat pengetahuan dan presisi. Untuk tingkat pengetahuan dengan akurasi nilai p=0,574 dan koefsien korelasi adalah -0,053 sehingga Ho diterima, berarti tidak ada hubungan antara tingkat pengetahuan dengan akurasi.
Precision and Accuracy Analysis of Forward Method Pipetting and Reverse Method Pipetting by Technology of Medical Laboratory Students Pontianak Hendra Budi Sungkawa; Reni Endiani
Jurnal Laboratorium Khatulistiwa Vol 2, No 1 (2018): November 2018
Publisher : poltekkes kemenkes pontianak

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30602/jlk.v2i1.326

Abstract

Abstract:   Pipetting process of using standard pipetting and procedures greatly affect the precision and accuracy of the pipetting which have doneto get the right result and can be trusted then the result being must have lie within the control area and good in precision and accuracy. The purpose of this study is to know the difference of forward method pipetting and reverse method pipetting by Technology of Medical Laboratory Pontianak. The both of methods are have done and then have seen the difference. While the research design which have used in this research is observational analytics with comparative study. Based on the result of the research got result average precision of forward method is 99,25344% and average accuracy value of forwrd method is 96,5983% and average precision of reverse method is 99,65003% and average accuracy value of reverse method is 95,9493%. Of the results values then analyzed with statistic is Wilcoxon test and got result p = 0,000 (p<0,05) then Ha accepted, so there is a difference of forward method pipetting and reverse method pipetting by Technology of Medical Laboratory Pontianak.