Pelatihan Inspection Preventive Maintenance (IPM) Alat Cath Lab Yeni Pertiwi; M. Febry Rhomadhon; Nur Hadziqoh; Nani Lasiyah; Rino Ferdian
Abdimas Universal Vol. 4 No. 1 (2022): April
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Balikpapan (LPPM UNIBA)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36277/abdimasuniversal.v4i1.213

Abstract

Health equipment is a very crucial component in health services. In Indonesian Hospitals, the quality of medical devices is carried out by the Hospital Facility Maintenance Installation, which is abbreviated as IPSRS. Generally, IPSRS staff consists of human resources who have qualifications in Electromedical, Public Health, and Management qualifications. HR who carry out maintenance and repairs, hereinafter referred to as Preventive Maintenance Inspection (IPM) of medical devices, are HR with electromedical qualifications. Cath Lab is the latest technology in the medical world. Therefore, many electromedical technicians do not understand the latest developments in the Cath Lab IPM process. In order to prepare hospital services with quality Cath Lab tools, reliable human resources are needed in carrying out their HDI. For this reason, training on HDI from this Cath Lab equipment is needed. This HDI training was attended by 534 participants from all over Indonesia which was carried out through the Zoom Meetings Application. This training succeeded in increasing the ability of participants by 22.28% from the initial ability of 46.48% to 68.76%. The participants' satisfaction with the reliability of the resource persons, activity themes, communication, committee and media used in the training activities was 86.57% in the very satisfied category.
Pelatihan Inspection Preventive Maintenance (IPM) MRI Nani Lasiyah; M. Rio Oktaviano; Yeni Pertiwi; Nurhadziqoh; Romi Mulyadi; Rino Ferdian
Abdimas Universal Vol. 4 No. 2 (2022): Oktober
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Balikpapan (LPPM UNIBA)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36277/abdimasuniversal.v4i2.219

Abstract

In Indonesia, the quality assurance of medical devices is carried out by the Hospital Facility Maintenance Installation, abbreviated as IPSRS. Generally, IPSRS staff consists of Human Resources (HR) who have qualifications in Electromedical, Public Health, and Management qualifications. Human resources in charge of carrying out maintenance and repairs, hereinafter referred to as Preventive Maintenance Inspections (IPM) of medical devices, are human resources with electromedical qualifications. Magnetic Resonance Imaging (MRI) is an advanced medical device that combines computer technology, high magnetic fields (0.067.0 Tesla) and radio waves to produce cross-sectional images of the muscles of the human body. To prepare patient services in hospitals using an MRI tool, reliable human resources are needed in carrying out their HDI. For this reason, training on the HDI of this MRI equipment is needed. This HDI training was attended by 534 participants from all over Indonesia which was carried out through the Zoom Meeting Application. This training succeeded in increasing the ability of participants by 27.98% while the average satisfaction of training participants was assessed from 5 aspects, namely at 86.65%, so that the training carried out is in the very satisfactory category.
Analisis Uji Kesesuaian Pesawat Sinar X Radiografi Mobile Merk ALLENGERS Type MARS-6 SBM Nani Lasiyah; Yeni Pertiwi; Romi Mulyadi; Nofri Anto
STRING (Satuan Tulisan Riset dan Inovasi Teknologi) Vol 7, No 2 (2022)
Publisher : Universitas Indraprasta PGRI Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30998/string.v7i2.13922

Abstract

The advances in technology experience significant developments anually, especially in the medical devices in the form of mobile x ray. The use of mobile x-ray radiation in the field of radiodiagnostics for various medical purposes needs to pay attention to two aspects, namely the risks and benefits. Therefore, the radiation protection is needed to reduce the damaging effects of radiation caused by radiation exposure. To ensure the accuracy and safety in the use of X-ray radiation, calibration procedures or conformity tests are carried out periodically. This study performs a conformity test on a mobile general radiography machine ALLENGERS, type MARS-6 SBM, with serial number 2162 used to examine the patients. The results of the conformity test using the Collimator Test and coin markers, mobile X-ray were declared to have passed the test as seen in the results from measurements using a Lux Meter, namely 101 Lux, with the score of a coin marker collimator of 3%.
ANALISA PARAMETER FREKUENSI PADA PENGUJIAN DAN KALIBRASI ELEKTROSTIMULATOR Nur Hadziqoh; Romi Mulyadi; Nani Lasiyah; Muddasir Muddasir
Al Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sciences) Vol 12 No 1 (2023): Al-Tamimi Kesmas: Jurnal Ilmu Kesehatan Masyarakat (Journal of Public Health Sci
Publisher : Institut Kesehatan dan Teknologi Al Insyirah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35328/kesmas.v12i1.2445

Abstract

An electrostimulator is a device that produces millions of tiny electrical signals that enter the body through an electrode that is placed on the surface of the skin near the affected area or above it. Electrostimulators are widely used to determine the response of nerve and muscle cells to certain electrical stimuli. In this study, the process of analyzing the frequency parameters in the testing and calibration of the electrostimulator was carried out in which the calibration was aimed to find out some deviations between the calibrated tool and the calibrator. The method used is the work method that has been determined by the Ministry of Health of the Republic of Indonesia, which includes physical inspection and tool functions, electrical safety and frequency measurement performance testing. For the results of this study on physical examination and tool function by 10%, for electrical safety checks the value obtained is 40%, performance testing is 50%.
RADIOGRAPHIC IMAGE QUALITY ANALYSIS IN THORAX, ABDOMEN, AND BONE FRACTURE EXAMINATIONS WITH KV AND MAS PARAMETER VARIATIONS Zahra Putri Rahman; Rhamdani Syahputra; Nani Lasiyah
Multidiciplinary Output Research For Actual and International Issue (MORFAI) Vol. 5 No. 4 (2025): Multidiciplinary Output Research For Actual and International Issue
Publisher : RADJA PUBLIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54443/morfai.v5i4.3147

Abstract

This experimental study at Petala Bumi Public Hospital (Jan–Apr 2025) aimed to determine the optimal tube voltage (kV) and tube current–time product (mAs) settings to enhance conventional X-ray image quality for thoracic, abdominal, and bone fracture examinations. Radiographs were taken using varied kV–mAs combinations and analyzed with ImageJ software through grey-level histograms to assess brightness (mean pixel intensity) and contrast (standard deviation). The thoracic image with a mean of 127.117 and SD of 83.331 showed the best balance of brightness and contrast. The optimal abdominal image had a mean of 107.703 and SD of 66.725, while the best bone fracture image had an SD of 65.463, ensuring clear fracture visibility. The study confirms the effectiveness of ImageJ in objective image-quality evaluation and highlights the importance of adjusting exposure parameters to improve diagnostic clarity without increasing radiation dose.