Claim Missing Document
Check
Articles

Found 5 Documents
Search

THE INFLUENCE OF THE CULTURE OF LAW IN LAW ENFORCEMENT CRIMINAL ACTS IN THE FIELD OF FISHERIES Asis, Abd; Sofyan, Andi; -, Aswanto; Sampurno, Slamet
Journal of Humanity Vol 3, No 2 (2015): July 2015
Publisher : Journal of Humanity

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14724/jh.v3i2.34

Abstract

Indonesia has the potential of marine and fisheries and a good variety of renewable or not renewable, but in the field fishery optimally still hampered with the rampant practice of catching fish illegally or criminal acts in the field of fisheries. The purpose of this writing is to know the influence of the culture of law in law enforcement criminal acts in the field of fisheries. Writing this type of normative research using secondary data, then the data were analyzed qualitatively-normative, examine the way interpret and construct the statement contained in document per-Act. The results showed that the law is strongly influenced by factors such as, among others: values, attitudes, and the communitys view of called with cultures of law. Based on legal cultures which may give rise to differences in law enforcement between the communities that one with other communities. The legal culture is linked to the professionalism of law enforcers in the exercise of his duties, and public awareness in adhering to the law itself. Overall attitudes and values and behavior that determine the applicable law on society. Thus, the construction of the legal awareness should be oriented in an effort to promote the values underlying the legislation in question as well as paying attention to the communication of the ruling factor in order for the contents of such laws can be known by the public at large as the target of the rule of law itself. So the culture of the law contains the meaning of the process of internalization of values that are alive and thriving in the community who can serve as a cornerstone in understanding and law enforcement especially in the field of fisheries. Therefore, the fundamental issues should be against the law as already described above should be addressed properly
Perbandingan Tingkat Kadar Gas SO2 dan NO2 di Udara Ambien Antara Metode Pasif dan Metode Aktif (Studi Kasus: Kota Jakarta) Indrawati, Asri; Tanti, Dyah Aries; Cholianawati, Nani; Sofyan, Andi; Cahyono, Waluyo EKo
Jurnal Teknologi Lingkungan Vol. 22 No. 1 (2021)
Publisher : Center for Environmental Technology - Agency for Assessment and Application of Technology

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2319.693 KB) | DOI: 10.29122/jtl.v22i1.4182

Abstract

ABSTRACT A comparison of the measurement results between the active method and the passive method was carried out to see the correlation between the resulting concentrations. The passive method used CSIRO passive sampler, while the active method used the Air Quality Monitoring System (AQMS). Sampling was conducted at AQMS Bundaran HI Jakarta Station, belonging to the Environment Laboratory of DLH DKI Jakarta. The sampling period was February - April 2019 for SO2 and NO2 parameters, with a sampling duration of three days for each data. Data was proceed using the correlation method. Data filtering with boxplot was used to filter outlier data from the passive sampler and AQMS measurements. Meteorological factors were included in the correlation calculations because of their effect on gas absorption that occurred in the passive sampler. Meteorological factors used were temperature, humidity, and wind direction. The AQMS concentration value prediction was calculated using the correlation equation between the passive sampler and the AQMS. The results showed that the correlation coefficient value between the passive sampler and AQMS was 0.67 for SO2 and NO2 of 0.79. Multivariate correlation using meteorological data, to improve the correlation value, obtained correlation values of 0.97 for SO2 and 0.94 for NO2. The predictive value of AQMS used a regression equation, with an average bias value of 4.4% for SO2 and 9.9% for NO2, while the RMSE values were 0.89 for SO2 and 4.41 for NO2. The results showed that the concentration of SO2 and NO2 gas measurement results from the passive and active methods had a good and significant correlation. Keywords: passive method, active method, SO2, NO2, AQMS   ABSTRAK Perbandingan hasil pengukuran antara metode aktif dan metode pasif dilakukan untuk melihat korelasi konsentrasi yang dihasilkan antara metode aktif dan metode pasif. Metode pasif menggunakan passive sampler CSIRO, sedangkan metode aktif menggunakan Air Quality Monitoring System (AQMS). Sampling dilakukan di Stasiun Pemantauan Kualitas Udara (SPKU) DKI 1 Bundaran HI milik  Laboratorium Lingkungan Hidup DLH DKI Jakarta. Periode sampling dilakukan dari bulan Februari – April 2019 untuk parameter SO2 dan NO2, dengan durasi sampling per tiga hari untuk satu data. Pengolahan data dilakukan dengan metode korelasi. Filter data dilakukan dengan menggunakan boxplot untuk memfilter data outlier dari pengukuran passive sampler dan AQMS. Faktor meteorologi dimasukkan dalam perhitungan korelasi karena pengaruhnya pada penyerapan gas yang terjadi di passive sampler. Faktor meteorologi yang digunakan adalah temperatur, kelembapan, dan arah angin. Prediksi nilai konsentrasi AQMS dihitung dengan menggunakan persamaan korelasi antara passive sampler dengan AQMS. Hasil yang diperoleh menunjukkan nilai koefisien korelasi antara passive sampler dengan AQMS sebesar 0,67 untuk SO2 dan NO2 sebesar 0,79. Korelasi multivariat menggunakan data meteorologi untuk memperbaiki nilai korelasi diperoleh nilai korelasi 0,97 untuk SO2 dan 0,94 untuk NO2. Nilai prediksi AQMS menggunakan persamaan regresi, dengan nilai rata-rata bias 4,4% untuk SO2 dan 9,9% untuk NO2, sedangkan nilai RMSE sebesar 0,89 untuk SO2 dan 4,41 untuk NO2. Hasil penelitian menunjukkan bahwa konsentrasi hasil pengukuran gas SO2 dan NO2 metode pasif dan metode aktif mempunyai korelasi yang baik dan signifikan. Kata kunci: metode pasif, metode aktif, SO2, NO2, AQMS
Perbandingan Tingkat Kadar Gas SO2 dan NO2 di Udara Ambien Antara Metode Pasif dan Metode Aktif (Studi Kasus: Kota Jakarta) Indrawati, Asri; Tanti, Dyah Aries; Cholianawati, Nani; Sofyan, Andi; Cahyono, Waluyo EKo
Jurnal Teknologi Lingkungan Vol. 22 No. 1 (2021)
Publisher : Center for Environmental Technology - Agency for Assessment and Application of Technology

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2319.693 KB) | DOI: 10.29122/jtl.v22i1.4182

Abstract

ABSTRACT A comparison of the measurement results between the active method and the passive method was carried out to see the correlation between the resulting concentrations. The passive method used CSIRO passive sampler, while the active method used the Air Quality Monitoring System (AQMS). Sampling was conducted at AQMS Bundaran HI Jakarta Station, belonging to the Environment Laboratory of DLH DKI Jakarta. The sampling period was February - April 2019 for SO2 and NO2 parameters, with a sampling duration of three days for each data. Data was proceed using the correlation method. Data filtering with boxplot was used to filter outlier data from the passive sampler and AQMS measurements. Meteorological factors were included in the correlation calculations because of their effect on gas absorption that occurred in the passive sampler. Meteorological factors used were temperature, humidity, and wind direction. The AQMS concentration value prediction was calculated using the correlation equation between the passive sampler and the AQMS. The results showed that the correlation coefficient value between the passive sampler and AQMS was 0.67 for SO2 and NO2 of 0.79. Multivariate correlation using meteorological data, to improve the correlation value, obtained correlation values of 0.97 for SO2 and 0.94 for NO2. The predictive value of AQMS used a regression equation, with an average bias value of 4.4% for SO2 and 9.9% for NO2, while the RMSE values were 0.89 for SO2 and 4.41 for NO2. The results showed that the concentration of SO2 and NO2 gas measurement results from the passive and active methods had a good and significant correlation. Keywords: passive method, active method, SO2, NO2, AQMS   ABSTRAK Perbandingan hasil pengukuran antara metode aktif dan metode pasif dilakukan untuk melihat korelasi konsentrasi yang dihasilkan antara metode aktif dan metode pasif. Metode pasif menggunakan passive sampler CSIRO, sedangkan metode aktif menggunakan Air Quality Monitoring System (AQMS). Sampling dilakukan di Stasiun Pemantauan Kualitas Udara (SPKU) DKI 1 Bundaran HI milik  Laboratorium Lingkungan Hidup DLH DKI Jakarta. Periode sampling dilakukan dari bulan Februari – April 2019 untuk parameter SO2 dan NO2, dengan durasi sampling per tiga hari untuk satu data. Pengolahan data dilakukan dengan metode korelasi. Filter data dilakukan dengan menggunakan boxplot untuk memfilter data outlier dari pengukuran passive sampler dan AQMS. Faktor meteorologi dimasukkan dalam perhitungan korelasi karena pengaruhnya pada penyerapan gas yang terjadi di passive sampler. Faktor meteorologi yang digunakan adalah temperatur, kelembapan, dan arah angin. Prediksi nilai konsentrasi AQMS dihitung dengan menggunakan persamaan korelasi antara passive sampler dengan AQMS. Hasil yang diperoleh menunjukkan nilai koefisien korelasi antara passive sampler dengan AQMS sebesar 0,67 untuk SO2 dan NO2 sebesar 0,79. Korelasi multivariat menggunakan data meteorologi untuk memperbaiki nilai korelasi diperoleh nilai korelasi 0,97 untuk SO2 dan 0,94 untuk NO2. Nilai prediksi AQMS menggunakan persamaan regresi, dengan nilai rata-rata bias 4,4% untuk SO2 dan 9,9% untuk NO2, sedangkan nilai RMSE sebesar 0,89 untuk SO2 dan 4,41 untuk NO2. Hasil penelitian menunjukkan bahwa konsentrasi hasil pengukuran gas SO2 dan NO2 metode pasif dan metode aktif mempunyai korelasi yang baik dan signifikan. Kata kunci: metode pasif, metode aktif, SO2, NO2, AQMS
PERANCANGAN GENERATOR MAGNET PERMANEN SATU PHASA TIPE AXIAL KECEPATAN RENDAH Khair, Muhammad Rezki; Sofyan, Andi; Anugrah, Anggun; Anthony, Zuriman
Kohesi: Jurnal Sains dan Teknologi Vol. 6 No. 4 (2024): Kohesi: Jurnal Sains dan Teknologi
Publisher : CV SWA Anugerah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.3785/kohesi.v6i4.9585

Abstract

Artikel ini membahas perancangan dan pembuatan generator magnet permanen satu phasa tipe axial kecepatan rendah yang bertujuan meningkatkan efisiensi konversi energi dari sumber daya alam menjadi listrik, terutama untuk pembangkit listrik tenaga angin skala kecil. Generator ini menggunakan prinsip kerja generator magnet permanen sinkron (PMSG), yang tidak memerlukan sikat atau trafo pada rotor, sehingga mengurangi perawatan dan biaya operasional. Penelitian ini mengungkapkan bahwa tegangan yang dihasilkan oleh generator dipengaruhi oleh beberapa faktor, seperti jumlah lilitan stator, kuat medan magnet, luas permukaan stator, dan kecepatan putar rotor. Pada uji coba, generator berhasil menghasilkan tegangan 183,3 volt pada kecepatan 500 rpm dengan frekuensi 50 Hz. Nilai medan magnet yang dihasilkan tercatat sebesar 2,766 Tesla, menunjukkan kinerja yang cukup baik dalam menghasilkan energi listrik pada kecepatan rendah. Hasil penelitian ini menunjukkan bahwa generator magnet permanen tipe axial kecepatan rendah memiliki potensi besar untuk digunakan dalam aplikasi pembangkit listrik skala kecil. Dengan desain yang efisien dan bebas dari komponen yang memerlukan perawatan rutin, generator ini bisa menjadi solusi yang efektif untuk pemanfaatan energi terbarukan dari sumber daya alam, seperti angin.
STUDI PERANCANGAN DAN PEMBUATAN GENERATOR MAGNET PERMANEN SATU PHASA 230 VOLT 8 KUTUB (DESAIN GENERATOR TESLA) Putra, Fauzan Masdia; Sofyan, Andi; Anugrah, Anggun; Anthony, Zuriman; Erhaneli, Erhaneli
Kohesi: Jurnal Sains dan Teknologi Vol. 6 No. 7 (2025): Kohesi: Jurnal Sains dan Teknologi
Publisher : CV SWA Anugerah

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.3785/kohesi.v6i7.10140

Abstract

Electromagnetics is an important phenomenon in everyday life and has a role in various technologies. Generators are divided into 2 types, namely AC generators and DC generators. This research aims to design and manufacture a single-phase 8-pole permanent magnet generator that can increase the efficiency of energy conversion from natural resources into electrical energy by improving the modeling of permanent magnet generators. The choice of this research is a synchronous permanent magnet generator (PMSG). The method used in the research is experimentation. The results showed that the voltage produced by this generator is influenced by several factors such as winding, magnetic field strength, stator surface area and rotor rotational speed. The voltage obtained in the no-load test is 241 volts at a speed of 1425 rpm with a frequency of 95 Hz. The magnetic field can be known through the electromagnetic voltage equation which in this study the magnetic field obtained is 0.313 T. This design, must be able to understand the materials used and it is important to learn the basics of permanent magnet generators when making prototypes. Elektromagnetik adalah fenomena penting dalam kehidupan sehari-hari dan memiliki peranan dalam berbagai teknologi. Generator terbagi 2 jenis yaitu generator AC dan generator DC. Penelitian ini bertujuan untuk merancang dan membuat generator magnet permanen satu phasa 8 kutub yang dapat meningkatkan efisiensi konversi energi dari sumber daya alam menjadi energi listrik dengan memperbaiki pemodelan generator magnet permanen. Pilihan penelitian ini adalah generator permanen magnet sinkron (PMSG). Metode yang digunakan dalam penelitian yaitu eksperimen. Hasil penelitian menunjukkan bahwa tegangan yang dihasilkan oleh generator ini dipengaruhi beberapa faktor seperti lilitan, kuat medan magnet, luas permukaan stator dan kecepatan putar rotor. Tegangan yang didapatkan pada pengujian tanpa beban adalah 241 volt di kecepatan 1425 rpm dengan frekuensi 95 Hz. Medan magnet dapat diketahui melalui persamaan tegangan elektromagnetik yang dalam penelitian ini medan magnet yang didapat bernilai 0,313 T. Perancangan ini, harus dapat memahami material yang digunakan dan penting untuk mempelajari dasar-dasar generator magnet permanen saat membuat prototype.