Andrey Nino Kurniawan, Andrey Nino
Technic of Radiodiagnostic and Radiotherapy Department, Polytechnic Health Ministry of Semarang

Published : 12 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 12 Documents
Search

Analisis Informasi Anatomi Pemeriksaan MRI Ankle Joint pada Penggunaan Foot Ankle Coil dan Flex Coil Proton Density Fat Saturation Irisan Sagital Kartikasari, Yeti; Kurniawan, Andrey Nino; Hidayat, Subhan Syarif
Jurnal Imejing Diagnostik (JImeD) Vol. 10 No. 1: JANUARY 2024
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v10i1.10268

Abstract

Background: To get good MRI image quality, a special coil is designed according to the type of examination with various types and sizes so that it can be adjusted to the body to be examined so that the selection of coil is very important in MRI examination. At Dr.R.Soeharso Surakarta Orthopedi Hospital, it was found on an MRI examination of the  ankle joint using a foot ankle  coil and also sometimes also using a flex coil. The purpose of this study was to determine the difference in anatomical information of ankle joint MRI examination on Proton Density Fat Saturation Sagittal Slices using foot ankle coil and flex coil.   Methods: This research is quantitative research with an experimental approach. This research was conducted on 10 volunteers. Respondents assessed image information on the anatomy of the Achilles tendon, talocalcaneal ligament, tibiofibular ligament, talofibular ligament, talotibial ligament, tenton flexor digitorum, extensor digitorum tendon, os calcaneus, os tallus, os tibia. Results: Ten probandus were performed MRI examination of ankle joint, proton density weighting, sagittal slice using foot ankle coil and flex coil. Images are produced that can show predetermined anatomical information, namely: Achilles tendon, talocalcaneal ligament, tibiofibular ligament, talofibular ligament, talotibial ligament, tenton flexor digitorum, extensor digitorum tendon, os calcaneus, os tallus, os tibia. Based on Wilcoxon's nonparametric statistical test in table shows that the resulting p value is 0.001 (p-value is <0.05) which means that there is a significant difference in the overall anatomical information of ankle joint MRI examination on the use of foot ankle coil and flex coil proton density fat saturation sagittal slices and mean rank results (28.50) foot ankle coil (0,001) flex coil.Conclusions: The anatomical information produced in the use of foot ankle coil is better than the anatomical information produced by flex coil on MRI examination of ankle joint proton density fat saturation sagittal slice.
Pelatihan Penggunaan Cairan Klorin Untuk Menurunkan Angka Mikroorganisme Pada Kaset Radiografi Kurniawati, Ary; Handoko, Bagus Dwi; Kurniawan, Andrey Nino
Madani : Indonesian Journal of Civil Society Vol. 6 No. 1 (2024): Madani : Februari 2024
Publisher : Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/madani.v6i1.1845

Abstract

Radiography has an important role in diagnosing a patient's disease, but the equipment used has a considerable risk as a place for the development of nosocomial bacteria which can endanger the patient and radiographer. Cassettes, one of the tools in radiography, have the potential to become a medium for disease transmission and based on previous research it has been proven that there are microorganisms and fungi on the cassettes, so the cassettes need to be cleaned regularly. One of the duties of a radiographer in the field of radiology services is the management of radiology equipment facilities and infrastructure. Cleaning the cassette with 70% alcohol can reduce the number of microorganisms on its surface. The methods in this activity are lectures, simulations, and practice cleaning cassettes with chlorine. The activities were carried out at the Laboratory of the Department of Radiodiagnosis and Radiotherapy Technique at the Semarang Health Polytechnic Ministry with radiographers from hospitals and clinical laboratories in the city of Semarang. The activity begins with the registration, opening, delivering material to the participants, and the simulation of resource persons. Evaluation is done by filling in the pretest and posttest. The evaluation results showed an increase in participants' knowledge of 63% about how to clean cassettes using liquid chlorine to reduce the number of microorganisms on radiographic cassettes. With this training, radiographers are expected to be able to apply cleaning radiographic cassettes with liquid chlorine 0,5% in their respective institutions.