ANALISIS KALIBRASI SUHU DAN KEBISINGAN PADA INKUBATOR PERAWATAN MENGGUNAKAN METODE ECRI Zulfahmi Zulfahmi; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol 2 No 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (411.996 KB)

Abstract

Incubator is a very important tool in hospitals, especially for premature babies. Because this tool is very related to the safety and survival of the baby, periodic calibration is needed. The purpose of this research is to find out the calibration techniques and the calculation of uncertainty of the data resulting from temperature and noise measurements. The incubator calibration activity refers to the ECRI method 415-20010301-01. As the determination of the threshold value or test passing value is +- 1C for temperature and <-65 dBA for noise. The results obtained from the calibration and calculation are 31.89 +- 0.48 C for temperature and 44.7 +- 7.2 dBA for noise. From these results it was stated that the CHS-i1000 incubator was declared suitable for use.
ANALISIS KALIBRASI SUHU PADA INFANT WARMER MENGGUNAKAN METODE ECRI 415-200010301-01 Iwan Ara Rizki; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol 3 No 1 (2019): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (343.193 KB)

Abstract

Infant warmer is an electromedic device which is used to provide comfort and warmth in a newborn, where the baby needs a temperature that is in accordance with the temperature in the mother’s womb,which is between 34 C - 37 C. Infant warmer calibration activities refer to the ECRI method 415-20010301. As the treshold value or the value of passing the test is +- 2 C for temperature. The results obtained from calibration are 31,89+- 0,51 C for temperature. From these results it was stated that the GIGANTE infant warmer was declared to be suitable for use.
ANALISA ALUR KERJA INSPIRASI DAN EKSPIRASI PADA ALAT VENTILATOR Franedya Argarini Saragih; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol 4 No 1 (2020): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (435.938 KB)

Abstract

Research has been carried out on the Hamilton C2 ventilator which aims to find out how the of inspiration and expiration are in accordance with what has been set on the ventilator by the operator or user. Installation of a ventilator is meant for patients who have excess or lack of oxygen within the lungs and who experience respiratory failure. Where the ventilator is a breathing apparatus that can help maintain ventilation and oxygen delivery for quite a long time.This research method is disbursed using qualitative and quantitative methods in order to collect data. Research on this ventilator was applied in several stages, namely setting and taking data that the ventilator on Volume Tidal (VT) must be in accordance with the Volume Tidal Expiratory (VTE) so there's no collapse within the patient and damage to the device itself. The results of this study are to determine the way of inspiration and expiration consistent with what has been set by observing the worth displayed on the Volume Tidal Expiratory (VTE) which is the same because the value that has been inputted within the Volume Tidal (VT. If the value displayed on the display or screen is <10% then there's a possibility of harm to the ventilator flow sensor or flow sensor within the patient, and the other way around if the value displayed on the display or screen is >10% then there's a possibility of injury to the flow sensors, both ventilator flow sensors and flow sensors within the patient.
ANALISA ALUR KERJA INSPIRASI DAN EKSPIRASI PADA ALAT VENTILATOR Franedya Argarini Saragih; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol. 4 No. 1 (2020): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v4i1.3240

Abstract

Research has been carried out on the Hamilton C2 ventilator which aims to find out how the of inspiration and expiration are in accordance with what has been set on the ventilator by the operator or user. Installation of a ventilator is meant for patients who have excess or lack of oxygen within the lungs and who experience respiratory failure. Where the ventilator is a breathing apparatus that can help maintain ventilation and oxygen delivery for quite a long time.This research method is disbursed using qualitative and quantitative methods in order to collect data. Research on this ventilator was applied in several stages, namely setting and taking data that the ventilator on Volume Tidal (VT) must be in accordance with the Volume Tidal Expiratory (VTE) so there's no collapse within the patient and damage to the device itself. The results of this study are to determine the way of inspiration and expiration consistent with what has been set by observing the worth displayed on the Volume Tidal Expiratory (VTE) which is the same because the value that has been inputted within the Volume Tidal (VT. If the value displayed on the display or screen is <10% then there's a possibility of harm to the ventilator flow sensor or flow sensor within the patient, and the other way around if the value displayed on the display or screen is >10% then there's a possibility of injury to the flow sensors, both ventilator flow sensors and flow sensors within the patient.
ANALISA SISTEM PEMELIHARAAN ALAT TENSIMETER Sri Ayu Tugi Astuti; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol. 4 No. 2 (2020): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The purpose of this study was to determine how the implementation of the tensimeter maintenance system at the Simpang Dolok Health Center Laboratory. This research is a qualitative descriptive study. The data was collected through tensimeter maintenance techniques. So that the Simpang Dolok Community Health Center performs routine cleaning and maintenance of the tensimeter in order to make the tensimeter last longer during its serviceable period. It is recommended that the head of the Simpang Dolok Health Center Laboratory room pay attention to the equipment maintenance system.
PENGARUH DAYA HISAP TERHADAP ALAT SUCTION PUMP Iqbal Eka Riansyah; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol. 5 No. 2 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v5i2.3362

Abstract

Research on the effect of suction power on the YB-DX23B smaf suction pump has been carried out.The method used in this research is quantitative experiment by measuring, testing and collecting data directly on the suction pump. The measuring instrument used is Vacum Gauge Meter. By using water as an object to replace blood and with a predetermined 10 second timer set, set the volume to adjust the volume of water you want and set the regulator to adjust how much suction power is needed.This research was conducted at the Electronics Laboratory of Sari Mutiara University- Indonesia. The results of this research are when the regulator is set at parameter -100 mmHg, the output on the vacuum gauge meter becomes -10 cmHg and the liquid is inhaled as much as 700 ml, when the regulator is set at parameter -200 mmHg, the output on the vacuum gauge meter becomes -20 cmHg and the liquid is inhaled as much as 1000 ml, when the regulator is set at the parameter -300 mmHg, the output on the vacuum gauge meter becomes -30cmHg and the liquid sucked is 1300 ml, and the regulator is set to the parameter -400 mmHg and the output on the vacuum gauge meter becomes -40 cmHg and the liquid is inhaled as much as 1500 ml.Measurements using a vacum gauge on the suction pump according to the settings set by the user. The greater the vacuum power, the faster the process of suctioning thevolume of liquid in.
ANALISIS KALIBRASI SUHU DAN KEBISINGAN PADA INKUBATOR PERAWATAN MENGGUNAKAN METODE ECRI Zulfahmi Zulfahmi; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol. 2 No. 1 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Incubator is a very important tool in hospitals, especially for premature babies. Because this tool is very related to the safety and survival of the baby, periodic calibration is needed. The purpose of this research is to find out the calibration techniques and the calculation of uncertainty of the data resulting from temperature and noise measurements. The incubator calibration activity refers to the ECRI method 415-20010301-01. As the determination of the threshold value or test passing value is +- 1C for temperature and <-65 dBA for noise. The results obtained from the calibration and calculation are 31.89 +- 0.48 C for temperature and 44.7 +- 7.2 dBA for noise. From these results it was stated that the CHS-i1000 incubator was declared suitable for use.
ANALISIS KALIBRASI SUHU PADA INFANT WARMER MENGGUNAKAN METODE ECRI 415-200010301-01 Iwan Ara Rizki; Hotromasari Dabukke
JURNAL MUTIARA ELEKTROMEDIK Vol. 3 No. 1 (2019): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Infant warmer is an electromedic device which is used to provide comfort and warmth in a newborn, where the baby needs a temperature that is in accordance with the temperature in the mother’s womb,which is between 34 C - 37 C. Infant warmer calibration activities refer to the ECRI method 415-20010301. As the treshold value or the value of passing the test is +- 2 C for temperature. The results obtained from calibration are 31,89+- 0,51 C for temperature. From these results it was stated that the GIGANTE infant warmer was declared to be suitable for use.