Audit Energi Listrik pada Bangunan Gedung SMKN 3 Kuningan Sofia Nurul Fajri; Nundang Busaeri; Imam Taufiqurrahman
E-JOINT (Electronica and Electrical Journal Of Innovation Technology) Vol. 5 No. 1 (2024): E-JOINT, Juni 2024
Publisher : Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/e-joint.v5i1.2376

Abstract

This research discusses Energy Audit at SMKN 3 Kuningan with the objective of evaluating the energy consumption intensity (IKE) in the buildings of SMKN 3 Kuningan. The methodology applied in this research involves measuring energy consumption through an energy audit and evaluating the measurement results based on IKE. The results obtained from data processing show that the total electrical energy consumption of the SMKN 3 Kuningan buildings is 112,613.11 kWh/year. Electrical energy consumption in air-conditioned rooms accounts for 80% of the total energy consumption, with electrical energy usage of 7,473 kWh/month, while non-air-conditioned rooms account for 20% of the total energy consumption, with an energy usage of 1,854 kWh/month. The calculated IKE value for air-conditioned rooms in SMKN 3 Kuningan buildings is 1.88 kWh/m²/month. Therefore, the air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 8.5 kWh/m²/month. The calculated IKE value for the non-air-conditioned rooms in SMKN 3 Kuningan buildings is 0.25 kWh/m²/month. Thus, the non-air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 3.4 kWh/m²/month. Both air-conditioned and non-air-conditioned rooms in the SMKN 3 Kuningan buildings meet the criteria for very efficient energy consumption intensity. Nevertheless, further research on energy saving opportunities can still be conducted to minimize electricity consumption costs at SMKN 3 Kuningan.
Audit Energi Listrik pada Bangunan Gedung SMKN 3 Kuningan Sofia Nurul Fajri; Nundang Busaeri; Imam Taufiqurrahman
E-JOINT (Electronica and Electrical Journal Of Innovation Technology) Vol 5 No 1 (2024): E-JOINT, Juni 2024
Publisher : Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/e-joint.v5i1.2376

Abstract

This research discusses Energy Audit at SMKN 3 Kuningan with the objective of evaluating the energy consumption intensity (IKE) in the buildings of SMKN 3 Kuningan. The methodology applied in this research involves measuring energy consumption through an energy audit and evaluating the measurement results based on IKE. The results obtained from data processing show that the total electrical energy consumption of the SMKN 3 Kuningan buildings is 112,613.11 kWh/year. Electrical energy consumption in air-conditioned rooms accounts for 80% of the total energy consumption, with electrical energy usage of 7,473 kWh/month, while non-air-conditioned rooms account for 20% of the total energy consumption, with an energy usage of 1,854 kWh/month. The calculated IKE value for air-conditioned rooms in SMKN 3 Kuningan buildings is 1.88 kWh/m²/month. Therefore, the air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 8.5 kWh/m²/month. The calculated IKE value for the non-air-conditioned rooms in SMKN 3 Kuningan buildings is 0.25 kWh/m²/month. Thus, the non-air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 3.4 kWh/m²/month. Both air-conditioned and non-air-conditioned rooms in the SMKN 3 Kuningan buildings meet the criteria for very efficient energy consumption intensity. Nevertheless, further research on energy saving opportunities can still be conducted to minimize electricity consumption costs at SMKN 3 Kuningan.
ANALISIS PELUANG EFISIENSI MELALUI KONSERVASI ENERGI PADA SISTEM TATA UDARA DI GEDUNG RUMAH SAKIT UMUM NURHAYATI GARUT Nadya Aprilia; Nundang Busaeri; Andri Ulus Rahayu
E-JOINT (Electronica and Electrical Journal Of Innovation Technology) Vol 4 No 1 (2023): E-JOINT, Juni 2023
Publisher : Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/e-joint.v4i1.1925

Abstract

Penelitian membahas tentang konservasi energi pada sistem tata udara untuk meningkatkan efisiensi penggunaan energi listrik pada gedung karena penggunaan energi listrik pada gedung Rumah Sakit Umum Nurhayati 75% digunakan pada sistem tata udara. Tujuan penelitian ini adalah menganalisis konsumsi energi untuk mendapatkan penghematan energi pada sistem tata udara agar tercapainya konsumsi energi yang lebih efisien. Metode yang dilakukan pada penelitian ini adalah konservasi energi dengan audit energi dilakukan perhitungan IKE, dan peluang upaya penghematan energi pada sistem tata udara. Hasil yang diperoleh pada penelitian ini adalah nilai intensitas konsumsi energi (IKE) pada Rumah Sakit Umum Nurhayati untuk bangunan non AC sebesar 28,68 kWh/m2/tahun termasuk kategori “efisien” sedangkan bangunan ber AC termasuk kriteria “agak boros” yaitu sebesar 183,16 kWh/m2/tahun. Besarnya konsumsi energi sistem tata sebesar 470801 kWh/tahun dari total penggunaan energi pada gedung. Peluang penghematan energi yang direkomendasikan dengan hasil paling efisien adalah menggunakan jenis AC inverter hemat energi dan didapatkan penghematan sebesar 209244,2 kWh/tahun atau 44% per tahun, dan nilai IKE setelah penghematan menjadi 101,7 kWh/m2/tahun menjadi kategori “efisien” dengan payback period selama 1 tahun 8 bulan dari penghematan yang dilakukan.