Nur Fithriani F. Cholida
Departement Of Civil Engineering, Universitas Semarang, Semarang

Published : 6 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search
Journal : Journal of Advanced Civil and Environmental Engineering

Investigation on the Compressive Strength of Gunny Sack Fiber Concrete under High-Temperatures Nur Fithriani F. Cholida; Purwanto P.; Hani Purwanti
JACEE (Journal of Advanced Civil and Environmental Engineering) Vol 3, No 1 (2020): April
Publisher : Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jacee.3.1.27-35

Abstract

Gunny sack fiber concrete has not been explored especially the behavior under high temperatures. This paper presents the results of an experimental investigation of gunny sack fibrous concrete (percentage of 0.5% of volume) given a monotonic- compressive load. A number of cylindrical test specimens were made which consisted of control specimens and which were incinerated at temperatures of 300oC, 600oC and 900oC. The concrete -compressive strength was designed with three variations of the cement water ratio to get the compressive strength of a standard cylinder with normal, medium and high -quality compressive strength categories. Experimental results show that normal to high quality concrete can be produced with gunny sack fiber substitution. The compressive strength of the gunny sack fiber concrete decreased significantly from the control specimen to the specimen which was burned at 300oC. The loss of compressive strength from the control specimens to the post-burn specimens of medium quality and high -quality of gunny sack fiber concrete was the same compared with the loss of compressive strength of normal- quality concrete. This study also carried out a comparison of the degradation of the compressive strength of steel fibrous concrete with gunny sack fiber in post-burn conditions.
A Parametric Study of Confinement Effects to the Interaction Diagram of P-M for High-Strength Concrete Columns Nur Fithriani Fatma Cholida; A Antonius; Faiqun Ni'am
JACEE (Journal of Advanced Civil and Environmental Engineering) Vol 1, No 1 (2018): April
Publisher : Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jacee.1.1.30-37

Abstract

In reinforced concrete columns design, P-M interaction diagram is used as axial load control and column bending without taking into account the effect of lateral reinforcement bars. Design principles that ignore the effect of reinforcement bars will result in low value of actual axial capacity of column. This paper presents the effect of lateral reinforcement with a case study of square-sectional columns on high-strength concrete. The equation of unconfined concrete strength enhancement is based on Mander, Legeron, Imran, Antonius and Muguruma models. The reviewed parameters include compressive strength of concrete, reinforcement configuration, and spacings of confinement. The result of the analysis is a comparison of P-M diagram based on confinement models. It shows that confinement significantly influences axial capacity of column, yet it has a certain collapse point at point P = 0 in all models. This is caused by longitudinal reinforcement system. Configuration of reinforcement, spacing and confinement models greatly affects the collapse behavior of column, whether the collapse is classified as compressive collapse or tensile collapse based on the P-M diagram.
Performance of The Existing Building Under Earthquake Loads Based on Current Indonesian National Standard Lintang Enggartiasto; Nur Fithriani Fatma Cholida; Purwanto P
JACEE (Journal of Advanced Civil and Environmental Engineering) Vol 5, No 2 (2022): October
Publisher : Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jacee.5.2.94-102

Abstract

This paper presents the results of an assessment of the existing 5-storey building built in 1980, which aims to determine the level of safety against the most recent standards. The method used is non-destructive testing, collecting planning data in the form of as built drawings and implementation data. The assessment of the existing structure consists of an evaluation of the condition of the material, structural system, and analysis of the structure using the latest load standards. The test results of the existing structural material show that the compressive strength of the concrete still meets the requirements based on SNI-2847-2019. The results of the evaluation of the structure against earthquake loads show that the performance of the structure has a mass participation of 100% and the dynamic base shear force (V) reaches 100% of Vstatic therefore it meets the requirements in SNI 1726-2019. The results of the evaluation of the performance of the structure show that the lateral drift and P-delta effects still meet the requirements of the most recent standards. Horizontal and vertical structural irregularities are found in the existing structural system. The structure's overall performance level (X and Y direction earthquakes) is Damage Control. These results are still permitted for structures with a priority factor (Ie) 1.50, with an earthquake return period of 2500 years.