PENGUKURAN KUALITAS CITRA DIGITAL COMPUTED RADIOGRAPHY MENGGUNAKAN PROGRAM PENGOLAH CITRA Ningtias, D. R.; Suryono, S.; Susilo, S.
Jurnal Pendidikan Fisika Indonesia Vol 12, No 2 (2016): July 2016
Publisher : Physics Department, Faculty of Mathematics and Natural Sciences, Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jpfi.v12i2.5950

Abstract

Penelitian yang telah dilakukan adalah pembuatan dan penghitungan kualitas citra digital menggunakan program Modulation Transfer Function (MTF) pada sistem Computed Radiography (CR) untuk kegiatan Quality Control (QC). MTF dapat digunakan untuk menganalisis resolusi spasial citra digital secara akurat. Pada penelitian ini menggunakan phantom yang terbuat dari tembaga berukuran 15x15 cm dengan ketebalan 1 mm. Phantom dieksposi dengan variasi tegangan 50 kV, 60 kV, 70 kV dan 81 kV dan masing-masing dilakukan variasi arus. Data yang diperoleh berupa file citra digital radiografi format DICOM yang kemudian dilakukan analisis kualitas citranya menggunakan PC diluar sistem CR dengan metode MTF. Metode ini sangat efisien dalam melakukan QC resolusi spasial secara kuantitatif sehingga dapat digunakan untuk menilai kualitas pesawat CR. Hasil pengukuran menunjukkan bahwa semakin tinggi tegangan yang digunakan, maka kualitas citra semakin baik dengan arus optimal pada rentang 4-8 mAs dengan rata-rata nilai resolusi spasial 7,26 lp/mm.The research was analyzing of digital image quality by using Modulation Transfer Function (MTF) on Computed Radiography (CR) system for Quality Control (QC). MTF can be used for analyzing digital image spatial resolution accurately. The research used phantom that made of 15x15 cm2 copper and 1 mm thickness. The phantom was expounded with voltage variations by 50 kV, 60 kV, 70 kV dan 81 kV and each of them have been taken by variations of the current. The the image quality of data obtained in the form of radiography digital image files with DICOM format were then analyzed using PC out of CR system with methode of MTF. This methode is really efficient for QC spatial resolution quantitatively and so it can be used for assesing the quality of CR. The measurement results showed that the higher the voltage, the better image quality with optimal current was on the range between 4-8 mAs with the average value of MTF 7,26 lp/mm.
PENGUKURAN KUALITAS CITRA DIGITAL COMPUTED RADIOGRAPHY MENGGUNAKAN PROGRAM PENGOLAH CITRA Ningtias, D. R.; Suryono, S.; Susilo, S.
Jurnal Pendidikan Fisika Indonesia Vol 12, No 2 (2016)
Publisher : Department of Physics, Faculty of Mathematics and Natural Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jpfi.v12i2.5950

Abstract

Penelitian yang telah dilakukan adalah pembuatan dan penghitungan kualitas citra digital menggunakan program Modulation Transfer Function (MTF) pada sistem Computed Radiography (CR) untuk kegiatan Quality Control (QC). MTF dapat digunakan untuk menganalisis resolusi spasial citra digital secara akurat. Pada penelitian ini menggunakan phantom yang terbuat dari tembaga berukuran 15x15 cm dengan ketebalan 1 mm. Phantom dieksposi dengan variasi tegangan 50 kV, 60 kV, 70 kV dan 81 kV dan masing-masing dilakukan variasi arus. Data yang diperoleh berupa file citra digital radiografi format DICOM yang kemudian dilakukan analisis kualitas citranya menggunakan PC diluar sistem CR dengan metode MTF. Metode ini sangat efisien dalam melakukan QC resolusi spasial secara kuantitatif sehingga dapat digunakan untuk menilai kualitas pesawat CR. Hasil pengukuran menunjukkan bahwa semakin tinggi tegangan yang digunakan, maka kualitas citra semakin baik dengan arus optimal pada rentang 4-8 mAs dengan rata-rata nilai resolusi spasial 7,26 lp/mm.The research was analyzing of digital image quality by using Modulation Transfer Function (MTF) on Computed Radiography (CR) system for Quality Control (QC). MTF can be used for analyzing digital image spatial resolution accurately. The research used phantom that made of 15x15 cm2 copper and 1 mm thickness. The phantom was expounded with voltage variations by 50 kV, 60 kV, 70 kV dan 81 kV and each of them have been taken by variations of the current. The the image quality of data obtained in the form of radiography digital image files with DICOM format were then analyzed using PC out of CR system with methode of MTF. This methode is really efficient for QC spatial resolution quantitatively and so it can be used for assesing the quality of CR. The measurement results showed that the higher the voltage, the better image quality with optimal current was on the range between 4-8 mAs with the average value of MTF 7,26 lp/mm.
Improving Environmental Sensitivity through Problem-Based Hybrid Learning (PBHL): An Experimental Study Amin, S.; Sumarmi, S.; Bachri, S.; Susilo, S.; Mkumbachi, R. L.; Ghozi, A.
Jurnal Pendidikan IPA Indonesia Vol 11, No 3 (2022): September 2022
Publisher : Program Studi Pendidikan IPA Fakultas Matematika dan Ilmu Pengetahuan Alam (FMIPA)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jpii.v11i3.38071

Abstract

Students need to possess sensitivity to the environment in order to behave positively when they notice a problem and find the right solution. This study intends to investigate whether the PBHL model affects the environmental sensitivity of Social Science Education students on environmental issues and conservation materials. The quasi-experimental design of the pretest-posttest controlled group was used in this study. Students of the Social Science Education Department, Universitas Islam Negeri Maulana Malik Ibrahim Malang, Indonesia, were selected as research subjects using a purposive sampling technique. The research subjects were determined to consist of class D as the experimental class (29 students) and class B as the control class (29 students). Questionnaires with a Likert scale of 1 (strongly disagree) – 4 (strongly agree) were used in taking student environmental sensitivity data on environmental issues and conservation materials, totaling 28 items with indicators: knowledge, attitudes, and skills. Subsequently, the data were tested for normality and homogeneity and analyzed using an independent sample t-test. The results showed that the PBHL model had a significant effect on the environmental sensitivity of Social Science Education students on environmental issues and conservation materials ((p (0.009) α (0.05)). The average results of the sensitivity of the experimental class environment (N-Gain = 13.29) were higher than the control class (N-Gain = 8.75). This goal can be achieved through the syntax in the PBHL model. The suggestion for further research is that it is necessary to develop further by combining the PBHL model and interactive mobile learning media as a means for students to investigate and actualize problem-solving.
OPTIMASI CAIRAN PEMBANGKIT MESIN PENCUCI FILM RADIOGRAF PADA LABORATORIUM FISIKA MEDIK UNNES Rahayu Ningtias, Diah; Susilo, S.; Sutikno, S.
Dinamika Teknik Mesin: Jurnal Keilmuan dan Terapan Teknik Mesin Vol 3, No 2 (2013): Dinamika Teknik Mesin: Jurnal Keilmuan dan Terapan Teknik Mesin
Publisher : Universitas Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (95.843 KB)

Abstract

Automatic film washing machine (TAEHN, model TM 300E in Physics Laboratory of FMIPA Unnes was successfully optimized by variating temperatures of developer and fixer solution in the range of 28˚C until 40˚C with temperature interval of 2˚C. At the first, developer solution was variated at controlled fixer temperature namely 30˚C, then it was analyzed to fixer determine density of each radiograph film. The optimum temperature of developer solution is available to varying temperature of fixer solution. The optimum temperatures of developer solution and fixer solution are 32˚C and 32˚C, respectively.