Claim Missing Document
Check
Articles

Found 2 Documents
Search

Perancangan Alat Bantu Monitoring Kadar Ph pada Proses Pelapisan di PT XYZ Dengan Metode QFD Betara Churraera; Wiyono Sutari; Sheila Amalia Salma
JRSI (Jurnal Rekayasa Sistem dan Industri) Vol 9 No 02 (2022): Jurnal Rekayasa Sistem & Industri - Desember 2022
Publisher : School of Industrial and System Engineering, Telkom University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25124/jrsi.v9i02.572

Abstract

PT XYZ merupakan perusahaan yang bergerak di bidang industri furnitur, produk yang dihasilkan bermacam-macam, salah satunya adalah kursi lipat Yamato. Kursi lipat Yamato merupakan produk yang paling banyak diproduksi, proses produksi dari kursi lipat Yamato terdiri dari tiga proses, yaitu proses konstruksi, proses pelapisan nickel chrome, dan proses perakitan. Pada penelitian ini peneliti lebih fokus dalam proses pelapisan nickel chrome dikarenakan jumlah cacat terbanyak terdapat pada proses ini berdasarkan data historis dari bulan Juli 2020 hingga Desember 2021. Proses pelapisan nickel juga memiliki banyak jenis cacat di antaranya cacat belang, terbakar, kuning, dan lain sebagainya. Proses pelapisan nickel chrome merupakan suatu proses pengendapan logam pada permukaan suatu logam maupun non-logam secara elektrolis. Pada analisis permasalahan terdapat proses yang tidak terpenuhi menggunakan diagram Ishikawa, analisis 5 whys, dan FMEA diketahui bahwa faktor berpengaruh yaitu ketidaksesuaian kadar pH, untuk memperbaiki permasalahan tersebut maka dilakukan perancangan alat bantu. Metode yang digunakan untuk perancangan alat bantu merupakan metode QFD (Quality Function Deployment).QFD merupakan suatu cara untuk meningkatkan kualitas produk maupun jasa dengan memahami setiap kebutuhan konsumen, kemudian menghubungkannya melalui aspek teknis untuk menghasilkan produk atau jasa yang sesuai dengan kebutuhan konsumen pada setiap pembuatan produk atau jasa yang dihasilkan. Hasil dari penelitian ini merupakan alat bantu untuk memantau kadar pH agar dalam keadaan standar. Dengan diadakannya perancangan alat bantu monitoring kadar pH diharapkan dapat meminimasi defect yang terjadi dalam proses pelapisan.
Design of Ph Level Monitoring Tool in Coating Process at PT XYZ Using QFD Method Betara Churraera; Wiyono Sutari; Sheila Amalia Salma
Jurnal Rekayasa Sistem & Industri Vol 9 No 02 (2022): Jurnal Rekayasa Sistem & Industri
Publisher : School of Industrial and System Engineering, Telkom University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25124/jrsi.v9i02.572

Abstract

PT XYZ is a company engaged in the furniture industry, the products produced are various, one of which isthe Yamato folding chair. Yamato folding chairs are the most produced products, the production process ofYamato folding chairs consists of three processes, namely the construction process, the nickel chromeplating process, and the assembly process. In this study, the researchers focused more on the nickel chromeplating process because the most defects were in this process based on historical data from July 2020 toDecember 2021. The nickel plating process also has many types of defects including streaks, burns, yellow,and so on. Nickel chrome plating process is a metal deposition process on the surface of a metal or nonmetal electrolytically. In the analysis of the problem there is a process that is not fulfilled using the Ishikawadiagram, 5 whys analysis, and FMEA it is known that the influential factor is the incompatibility of pH levels,to correct these problems, a tool is designed. The method used for the design of the tool is the QFD (QualityFunction Deployment) method. QFD is a way to improve the quality of products and services byunderstanding each consumer's needs, then connecting them through technical aspects to produce productsor services that suit consumer needs in each manufacture product or service produced. The results of thisstudy are a tool to monitor pH levels so that they are in standard conditions. With the design of a monitoringtool for pH levels, it is expected to minimize defects that occur in the coating process.