Claim Missing Document
Check
Articles

Found 3 Documents
Search

Analisis Penggunaan Bolus Berbahan Plastisin pada Pasien Fibrosarcoma dengan Treatment Planning System (TPS) Riska Fitriani; Kadek Subagiada; Suhadi Muliyono; Robert Janssen Stevenly; Suryaningsih Suryaningsih
Progressive Physics Journal Vol 3 No 1 (2022): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (690.818 KB) | DOI: 10.30872/ppj.v3i1.818

Abstract

Bolus is a material that has properties similar to body tissues and is used to maximize the absorbed dose on the skin surface. The purpose of this research was to determine the most optimal treatment to kill fibrosarcoma on the patient’s skin surface by comparing the isodose curve and the value of the radiation absorption dose on the physical bolus (from CT-Scan) and model bolus (TPS). This study used data in the form of bolus images (with a bolus thickness of 0 cm, 0.5 cm and 1.0 cm) and phantom image. Then the data was processed with Treatment Planning System (TPS) and given energy variations in the form of electrons (10 MeV, 12 MeV, dan 15 MeV) and photons (6 MV and 10 MV). The result of this research was an isodosis curve that describes the distribution of the dose and the value of the absorbed dose of radiation received by the skin surface. The conclusion of this research is a bolus thickness of 0,5 cm and an electron energy of 15 MeV, has more even isodose curve (covering the entire tumor) and the maximum absorption dose value were 5720 cGy for physical bolus and 5710 cGy for TPS bolus.
Menentukan Intensitas Radiasi UV yang Diterima Pekerja Pengelasan dengan Titik Area Mata, Siku, dan Betis Muliana Dai; Kadek Subagiada; Adrianus Inu Natalisanto
Progressive Physics Journal Vol 2 No 1 (2021): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (885.122 KB) | DOI: 10.30872/ppj.v2i1.736

Abstract

The aim of this study is to measure the UV intensity received by the welders during working time and compare the results of measured radiation intensity which is obtained with the NAB in Regulation of the Minister of Manpower No. 05 of 2018 that is 0,0008 mW/cm2. The reason for using this NAB is for compare value while welding process with the value were allowed from Regulation of the Minister of Manpower. This study has been done in some workshops using the UV Meter and focused on the welders’ eye, elbow and calf area with 10 repetitions in each area. The results for eye area were 0.0749 mW/cm2, for elbow area were 0.0843 mW/cm2and for calf area were 0.0934 mW/cm2and all the results obtained exceed the NAB. The high value is caused by the environmental conditions is open and also affected by indeterminate sunlight, the risks received the welders in watery eye and headache because of the welder are disobey in using PPE while welding process.
Penentuan Nilai Faktor Mesin Pesawat Sinar-X Radiografi Digital Merek Shimadzu di RSUD Dr. Kanujoso Djatiwibowo Balikpapan Mamba'ul Fitriyana; Suhadi Muliyono; Kadek Subagiada
Progressive Physics Journal Vol 1 No 1 (2020): Progressive Physics Journal
Publisher : Program Studi Fisika, Jurusan Fisika, FMIPA, Universitas Mulawarman

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (596.21 KB) | DOI: 10.30872/ppj.v1i1.563

Abstract

The research on the determining machine factor (k) of Shimadzu digital radiograph X-ray machine have been done at the RSUD Dr. Kanujoso Djatiwibowo Balikpapan. Machine factor should be required in the calculation of radiation exposure which produced by the X-ray machine. Measurement data that have been used as independent variables were current-time, focus distance to the detector and tube voltage variations of 80 kV to 100 kV, while the dependent variable was the S value. Determination of the k value was conducted by weighted linear regression between V2 and using the results of research by Seibert and Morin (2011) for the condition of calibrated X-ray machine. Thus, the reseach has obtained the machine factor of the Shimadzu digital radiograph X-ray machine at the RSUD Dr. Kanujoso Djatiwibowo Balikpapan.