Perbandingan Efisiensi Cooling Tower Unit 2 PLTP Lahendong Sebelum dan Sesudah Overhaul Fingki Astrika Kulo; Rolles Nixon Palilingan; Cyrke A. N. Bujung
Jurnal FisTa : Fisika dan Terapannya Vol 4 No 1 (2023): APRIL
Publisher : Fakultas Matematika Ilmu Pengetahuan Alam dan Kebumian, Universitas Negeri Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/fista.v4i1.239

Abstract

Geothermal Power Plant (PLTP) is a power plant that utilizes the heat generated by the bowels of the earth to produce electricity. efficiency is defined as the ratio between output and input in a process. Efficiency is one of the important equations in thermodynamics to determine how well the energy conversion or transfer process occurs. The research location of PLTP Lahendong unit 2 is located in Tondangow Village, South Tomohon District. This study aims to determine the comparison of the efficiency of cooling tower unit 2 before and after overhaul by processing data using the Ms. software application. Based on the results of the analysis, the efficiency value of the cooling tower of PLTP Lahendong Unit 2 before overhaul has an average value of 59% and the average value of cooling tower efficiency after overhaul is 63%. The magnitude of the efficiency comparison from the overhaul results in the average value of cooling tower efficiency increasing by 4%.