Syamsi, Muhammad Ibnu
Universitas Muhammadiyah Yogyakarta

Published : 5 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 5 Documents
Search

Asesmen Cepat Kerentanan Bangunan Sekolah Muhammadiyah Terhadap Gempabumi di Kecamatan Kasihan Bantul DIY Faizah, Restu; Syamsi, Muhammad Ibnu
Semesta Teknika Vol 20, No 2 (2017): NOVEMBER 2017
Publisher : Semesta Teknika

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

School buildings are included as buildings with risk category IV (SNI 1726: 2012) because it is potentially causing multiple casualties if earthquakes occur during school hours. Therefore the readiness of school buildings to face the earthquakes should be prepared well. First of all, a rapid vulnerability assessment of the existing building under earthquake needs to be conducted. If the buildings are vulnerable then it should be followed by a strength check. This research objective is to assess the vulnerability of Muhammadiyah school buildings which are located in Kasihan sub-district of Bantul Regency, using Rapid Visual Screening FEMA 154-2002. There are 8 buildings, consist of elementary, middle school, and senior high school which are scattered in Tirtonirmolo, Tamantirto and Bangunjiwo, Kasihan, Bantul regency. According to FEMA 154-2002, the observation result finds that 4 schools indicated to have structure vulnerability under earthquake hazard so they need further analysis to know more detail about their strength. While the other 4 buildings do not need further analysis. The results of this study can be used as a recommendation for the Muhammadiyah Basic and Secondary Education Council (Majelis Pendidikan Dasar dan Menengah) to conduct more detailed testing for school buildings that are have vulnerabilites. In addition, this research method also can be extend to school buildings or non-school buildings in other areas. 
Perbandingan Analisis Two Way Slab With Beam dengan Flat Slab (Studi Kasus: Coal Yard PLTU Kalimantan Barat) Syamsi, Muhammad Ibnu
Semesta Teknika Vol 18, No 2 (2015): NOVEMBER 2015
Publisher : Semesta Teknika

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Floor slab of coal yard as a storehouse was designed as two way slab with beam and flat slab in order to compare those two systems based on needs of materials and ease of implementation. The design process is based on the provision of SNI 03-2847-2002. Through the design results and analysis of material requirements can be concluded that the need for concrete material on a flat slab system is 2.1% greater than on the two way slab with beam. Meanwhile the steel material requirements for flat slab system is 9.7% greater than two way slab with beam. However, in term of ease of implementation, relatively flat plate systems are superior to the briquette plate system because the number of items of work a little more
Respon Model Gedung Beton Bertulang dengan Penambahan Dinding Pengisi terhadap Beban Gempa Syamsi, Muhammad Ibnu
Semesta Teknika Vol 21, No 1 (2018): MEI 2018
Publisher : Semesta Teknika

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/st.211208

Abstract

Earthquake-resistant building structures designs usually are not considering the influence of non-structural walls. In fact, non-structural walls could give additional strength for building especially to help retaining seismic loads. The Influence of masonry walls on infill frame building structure model to the open frame model became the objective in this study. Spectrum response and time history are applied to both types of model to know and compare the behavior of those two samples. The observed building is an educational facility and located in an area prone to earthquakes. The parameters used in this research are based on natural periods, shear forces, and drift ratios. After performing linear analysis, the drift ratio on each floor of the building could be categorized as safe condition because it has not exceeded its limit. Structural models with masonry walls have larger stiffness than open frames. Moreover, the greater structure stiffness in the infill frame model is able to narrow the drifts that occur from the inter-story drift ratio to be smaller. Due to higher stiffness, the base shear results from structures with infill frame system models are also larger than structures modeled with open frames system.
Analisa Kerentanan Hunian Tetap di Kabupaten Cianjur dengan Evaluasi Probabilitas Percepatan Gerakan Tanah Syamsi, Muhammad Ibnu; Faizah, Restu; Monika, Fanny; Wicaksono, Imam
AGREGAT Vol 9 No 1 (2024)
Publisher : Universitas Muhammadiyah Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30651/ag.v9i1.22393

Abstract

Indonesia is one of the countries that has a fairly high seismic condition. This is because Indonesia is passed by the Pacific Ring of Fire, which brings together many world plates, so it is natural that many earthquakes occur in Indonesia. With a fairly high seismic condition, there is a need for vigilance and actions taken to overcome the situation. The infrastructure sector becomes an important spotlight when an earthquake occurs because casualties are often caused by structural failures that are not strong enough to withstand the earthquake load. This is similar to what happened in the earthquake in Cianjur in 2022, which claimed many lives due to the numerous structural failures in permanent residences. Therefore, this research was conducted to evaluate the permanent residences of the community related to the vulnerability that occurred due to the earthquake. Building vulnerability testing is carried out using the Incremental Dynamic Analysis (IDA) method with data from 11 earthquake records. Later, the building’s response to the earthquake load will be obtained, and the probability of damage seen from the vulnerability curve will be known. The five performance levels of the building are Operational Phase (OP), Immediate Occupancy (IO), Damage Control (DC), Life Safety (LS), and Collapse Prevention (CP).
Analisa Kerentanan Hunian Tetap di Kabupaten Cianjur dengan Evaluasi Probabilitas Percepatan Gerakan Tanah Syamsi, Muhammad Ibnu; Faizah, Restu; Monika, Fanny; Wicaksono, Imam
AGREGAT Vol 9 No 1 (2024)
Publisher : Universitas Muhammadiyah Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30651/ag.v9i1.22393

Abstract

Indonesia is one of the countries that has a fairly high seismic condition. This is because Indonesia is passed by the Pacific Ring of Fire, which brings together many world plates, so it is natural that many earthquakes occur in Indonesia. With a fairly high seismic condition, there is a need for vigilance and actions taken to overcome the situation. The infrastructure sector becomes an important spotlight when an earthquake occurs because casualties are often caused by structural failures that are not strong enough to withstand the earthquake load. This is similar to what happened in the earthquake in Cianjur in 2022, which claimed many lives due to the numerous structural failures in permanent residences. Therefore, this research was conducted to evaluate the permanent residences of the community related to the vulnerability that occurred due to the earthquake. Building vulnerability testing is carried out using the Incremental Dynamic Analysis (IDA) method with data from 11 earthquake records. Later, the building’s response to the earthquake load will be obtained, and the probability of damage seen from the vulnerability curve will be known. The five performance levels of the building are Operational Phase (OP), Immediate Occupancy (IO), Damage Control (DC), Life Safety (LS), and Collapse Prevention (CP).