PROTOTYPE OF AUTOMATIC DISINFECTANT TOOL BASED ON INTERNET OF THINGS (IOT) IMPROVES HEALTHY LIVING HABITS Binazun, Inayah; Adzin Murdiantoro, Randi; Nasrulloh; Munawar, Aris; Fachruroji
Journal of Electronic and Electrical Power Applications Vol. 4 No. 1 (2024): JEEPA Volume 4 Nomor 1
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v4i1.1911

Abstract

Covid is currently starting to subside, one of which is with the handling, recommendation for vaccines from dose 1 dose 2 and booster vaccines. Handling and recommendation for vaccines is one form of government policy and is one of the government's responsibility efforts to the community. The use of disinfectants can be one solution for the community to start living a healthy and clean life, but many people are reluctant to bring disinfectants to public places. The existence of a prototype of an automatic disinfectant tool can provide a solution for people who are reluctant to bring disinfectants out of the house, even every community house can make an automatic disinfectant tool for indoor use. Based on the results and discussions above, it can be concluded that the design of the prototype of an automatic disinfectant sprayer with a proximity sensor based on the internet of things (IOT) to support healthy living habits after the pandemic has been successfully carried out. While the results of the efficiency of the proximity sensor detection time against objects were 86.3% with a proximity sensor error value of 2.1%. The prototype of an automatic disinfectant sprayer with a proximity sensor based on the internet of things (IOT) has successfully sent the results of the prototype disinfectant usage counter to the telegram. Although there are still many shortcomings in this study in building a prototype of an automatic disinfectant sprayer with a proximity sensor based on the internet of things (IOT), the overall system that was built can run well..
HOTSPOT TEST EVALUATION USING THERMOVISI FLIR ON 60 MVA TRANSFORMER CONDUCTOR BAY III Fahturozi, Rela; Mubarok, Rizky; Munawar, Aris; Fachruroji
Journal of Electronic and Electrical Power Applications Vol. 4 No. 1 (2024): JEEPA Volume 4 Nomor 1
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v4i1.1913

Abstract

The operation of the transformer power distribution is the center of the transmission and distribution system. Given the almost continuous hard work of the transformer, its operation needs to be considered to prevent several disturbances that can reduce the optimal work of the transformer. One of the disturbances that can be found in the substation transformer is the hot-spot temperature at the terminal connection between the conductor cable and the equipment at the substation. This temperature is closely related to the protection and reliability of the system in the switchyard. To overcome the problems that occur in the transformer, especially the 150 kV Kalibakal Purwokerto Substation regarding the hot spots that occur at the transformer conductor bay connection. Routine temperature checks are carried out every day at the transformer connection point using a Thermovisi Flir E60 thermal imager measuring instrument that can determine the temperature value at the conductor connection clamp by looking at the infrared light from the tool. The results of the test evaluation carried out in this thermovisi method use the calculation of the temperature difference (∆T) between the clamp and the conductor, the results obtained are that none of the temperatures exceed >10˚C. The calculation of the emissivity value using Stefan Boltzman's law obtained an average emissivity of 0.506, which means it is included in the temperature range in accordance with the Standard Reference Material (SRM) (aluminum emissivity 0.5). Precision testing with a precision percentage expressed by the Coefficient of Variation (CV) obtained from 45 test points is 0.23%, this result can be categorized as a good result from the CV value standard of <2%. The calculation of the accuracy test found a result of 99.88%, which means that the points tested are still in good condition.
Reviving Local Heritage: Leadership in Building a Culture of Quality Daryanto, Daryanto; Carwa, Carwa; Astuti, Ida Yuli; Munawar, Aris; Kholisoh Nuryani, Lilis
JURNAL ISLAM NUSANTARA Vol 8, No 1 (2024)
Publisher : Lembaga Ta'lif wa An-Nasyr (LTN) PBNU

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33852/jurnalnu.v8i1.536

Abstract

This study analyzes leadership preferences in building a quality culture based on local wisdom in schools. The research method used is a qualitative case study approach involving in-depth interviews, participant observation, and document analysis. The data analysis technique used is thematic analysis, which includes systematic data coding, grouping similar codes, and drawing conclusions based on identified themes. The study results indicate that inclusive and supportive leadership strategies and the integration of local wisdom in teaching materials have succeeded in increasing student engagement in learning and strengthening their character. In addition, the findings show that the support of the principal in the form of policies and initiatives plays an essential role in the successful implementation of local wisdom-based programs. The implication of this study is the importance of school leadership in encouraging and supporting local culture-based programs to achieve more holistic and sustainable education.
COMPARATIVE ANALYSIS OF ON-GRID AND OFF-GRID SOLAR PANEL INSTALLATIONS IN A BUILDING WITH A REQUIREMENT OF 60.5 KWp Fachruroji; Wahyudi, Muhammad Firman; Mubarok, Rizky; Munawar, Aris
Journal of Electronic and Electrical Power Applications Vol. 4 No. 2 (2024): JEEPA Volume 4 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v4i2.2079

Abstract

Along with the increasing use of electrical energy and air pollution, one of which is caused by fossil fuel resources, has encouraged an increase in the use of renewable energy, especially solar power. Solar Power Plants (PLTS) have become an attractive alternative, especially for industrial and residential needs because they can reduce the cost of conventional electricity bills. At the design stage of the Solar Power Plant on-grid and off-grid systems in buildings with a power of 60,500 Wp by going through the stages of calculating the required load according to the conditions in the building, to obtain the required PLTS component capacity. In the long term, there will be an understanding of the use of renewable energy sustainably. The comparison results show that the cost between installing on-grid PLTS and installing off-grid PLTS is actually greater for on-grid PLTS with a cost of Rp. 444,301,500 than for installing off-grid PLTS with a cost of Rp. 332,214,000. However, the on-grid PLTS system offers a better system because it does not require a large area for battery storage, lower maintenance costs and can remain connected to the main network so it is very suitable for industrial needs.
THE EFFECT OF MAGNET LENGTH AND WIDTH ON FLUX LINKAGE IN A 12S8P PERMANENT MAGNET SYNCHRONOUS GENERATOR Setiawati, Yuli; Prasetyono, Rizki Noor; Munawar, Aris
Journal of Electronic and Electrical Power Applications Vol. 5 No. 1 (2025): JEEPA Volume 5 Nomor 1
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v5i1.2287

Abstract

Permanent Magnet Synchronous Generator 12S8P as an energy conversion tool. To increase the efficiency of electrical energy, it is necessary to design a generator using FEM software to simulate the length and width of the magnet, so that when making the generator it can achieve a high level of success. Experimental quantitative method by varying the length and width then analyzing how much influence it has on the flux linkage. The results of the influence of the length of the magnet and the width of the magnet on the resulting flux linkage, the calculated f value = 14.979 with a significance or probability level of 0.001 <0.05 which can be concluded that the data is acceptable and shows that variations in length and width (20 x 5 mm) have an effect on the flux linkage. In addition to the ANOVA results, the results of the summary model also show a large coefficient of determination of 0.591, which means that variations in length and width (20 x 5 mm) have an influence of 59.1% on the flux linkage, with the remaining 40.9% influenced by other factors. Meanwhile, in the variation of Length and Width (30 x 10 mm), the ANOVA results were obtained with a calculated f value = 18.979 with a significance or probability level of 0.001 <0.05, which can be concluded that the data can be accepted and the variation of Length and Width (30 x 10 mm) has an effect on flux linkage. In addition to the ANOVA results, the summary model results also showed a determination coefficient of 0.429, which means that variations in Length and Width (30 x 10 mm) have an influence of 42.9% on flux linkage, with the remaining 57.1% influenced by other factors.