Pengaruh Variasi Nilai mA (Mili Ampere) dan s (Second) yang Berbeda Dengan Nilai mAs yang Sama Terhadap Paparan Medik yang Diterima Pasien Maritje S. J. Malisngorar; Ira Sandi Tunny; Amelia Niwele; Akhmadi Akhmadi; Rini Hatma Rusli; Iksan Soumena; Bambang Ariyanto
Jurnal Sains dan Kesehatan Vol. 6 No. 1 (2022): Juni : Jurnal Sains dan Kesehatan (JUSIKA)
Publisher : Universitas Muhamadiyah Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57214/jusika.v6i1.522

Abstract

This study aims to find out how to measure exposure dose medical techniques which accepted the patients with a variety of ma and s at the same mas value and the effect of variations in the value of mili ampere and second different with the same mas value to medical exposure dose received by patients. This type of study is an observational descriptive with the approach of the experimental or trial. using gauges medic exposure dose, x-ray multimeter with research indicator mili ampere and second are different but the same mas. From these results it can be concluded the highest medical exposure dose received by patients is the variation of 200 ma and 0.05 s with a dose value of 5.533 mgy / s. this is due to the amount of flow tube (ma). it can be concluded that the greater ma is used, the greater the dose the patient received medical.
Literature Review Kesehatan dan Keselamatan Kerja Pelayanan Radioterapi pada Penggunaan Pesawat Linac Ira Sandi Tunny; Rini Hatma Rusli; Maritje S. J. Malisngorar; Iksan Soumena; Miranda Waas
Jurnal Sains dan Kesehatan Vol. 6 No. 1 (2022): Juni : Jurnal Sains dan Kesehatan (JUSIKA)
Publisher : Universitas Muhamadiyah Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57214/jusika.v6i1.523

Abstract

Occupational Health and Safety are conditions in work that are healthy and safe, both for the job, the company and for the community and environment around the factory or workplace. One of the K3 Standards according to the Ministry of Health as intended in paragraph (1) is aimed at preventing and reducing occupational diseases and other illnesses, as well as work accidents among employees, and creating safe, comfortable and efficient offices to encourage work productivity.The research method used in this research is library research which uses literature as the main object. This research carried out descriptive analysis, namely trying to describe the Occupational Health and Safety of Radiotherapy services when using LINAC aircraft. To find out Occupational Health and Safety in Radiotherapy services, researchers reviewed several literature including books, articles and journals related to Occupational Health and Safety in Radiotherapy services in several hospitals in Indonesia. The research results show that creating occupational health and safety in radiodiagnostic and radiotherapy services requires component compatibility. Good equipment, examination room design that complies with the rules, appropriate procedures, security systems, health monitoring of officers and policies from the highest responsible persons.
Perbandingan Kualitas Citra Radiograf Kepala Menggunakan Grid dan Tanpa Grid pada Computed Radiografi Rini Hatma Rusli; Ira Sandi Tunny; Maritje S. J. Malisngorar; Akhmadi Akhmadi; Yohannes Hursepunny
Jurnal Sains dan Kesehatan Vol. 6 No. 1 (2022): Juni : Jurnal Sains dan Kesehatan (JUSIKA)
Publisher : Universitas Muhamadiyah Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57214/jusika.v6i1.524

Abstract

One factor that plays an important role in the quality of radiodiagnostic examination results is radiographic contrast. When examining thick objects, radiographic contrast will decrease as a result of the large amount of scattered radiation originating from the object and reaching the film. To obtain optimal radiographic contrast on thick objects such as the head, it can be done in various ways, including using a grid. The grid is a tool that functions to absorb scattered radiation but can still transmit primary radiation. Examination of the head is done to get the head radiograph and to determine any abnormalities or diseases of the head. This examination was performed using the grid and without grid to compare the better results of radiographs. Radiographs results were obtained using processing film, Computed Radiography (CR). This research used descriptive study conducted at Hospital Tk. II Pelamonia Makassar on January 2020. Based on the results of the research which conducted for examination of the head using grid and without grid on CR cassette obtained that the result of radiograph examination of the head using a grid was better.
Pengaruh Variasi Nilai mA (Mili Ampere) dan s (Second) yang Berbeda Dengan Nilai mAs yang Sama Terhadap Paparan Medik yang Diterima Pasien Maritje S. J. Malisngorar; Ira Sandi Tunny; Amelia Niwele; Akhmadi Rini Hatma Rusli; Iksan Soumena; Bambang Ariyanto
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 2 (2022): JULI : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i2.4172

Abstract

This study aims to find out how to measure exposure dose medical techniques which accepted the patients with a variety of ma and s at the same mas value and the effect of variations in the value of mili ampere and second different with the same mas value to medical exposure dose received by patients. This type of study is an observational descriptive with the approach of the experimental or trial. using gauges medic exposure dose, x-ray multimeter with research indicator mili ampere and second are different but the same mas. From these results it can be concluded the highest medical exposure dose received by patients is the variation of 200 ma and 0.05 s with a dose value of 5.533 mgy / s. this is due to the amount of flow tube (ma). it can be concluded that the greater ma is used, the greater the dose the patient received medical.
Literature Review Kesehatan dan Keselamatan Kerja Pelayanan Radioterapi pada Penggunaan Pesawat Linac Ira Sandi Tunny; Rini Hatma Rusli; Maritje S. J. Malisngorar; Iksan Soumena; Miranda Waas
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 2 (2022): JULI : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i2.4174

Abstract

Occupational Health and Safety are conditions in work that are healthy and safe, both for the job, the company and for the community and environment around the factory or workplace. One of the K3 Standards according to the Ministry of Health as intended in paragraph (1) is aimed at preventing and reducing occupational diseases and other illnesses, as well as work accidents among employees, and creating safe, comfortable and efficient offices to encourage work productivity.The research method used in this research is library research which uses literature as the main object. This research carried out descriptive analysis, namely trying to describe the Occupational Health and Safety of Radiotherapy services when using LINAC aircraft. To find out Occupational Health and Safety in Radiotherapy services, researchers reviewed several literature including books, articles and journals related to Occupational Health and Safety in Radiotherapy services in several hospitals in Indonesia. The research results show that creating occupational health and safety in radiodiagnostic and radiotherapy services requires component compatibility. Good equipment, examination room design that complies with the rules, appropriate procedures, security systems, health monitoring of officers and policies from the highest responsible persons.
Perbandingan Kualitas Citra Radiograf Kepala Menggunakan Grid dan Tanpa Grid pada Computed Radiografi Rini Hatma Rusli; Ira Sandi Tunny; Maritje S. J. Malisngorar; Akhmadi Akhmadi; Yohannes Hursepunny
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 2 (2022): JULI : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i2.4176

Abstract

One factor that plays an important role in the quality of radiodiagnostic examination results is radiographic contrast. When examining thick objects, radiographic contrast will decrease as a result of the large amount of scattered radiation originating from the object and reaching the film. To obtain optimal radiographic contrast on thick objects such as the head, it can be done in various ways, including using a grid. The grid is a tool that functions to absorb scattered radiation but can still transmit primary radiation. Examination of the head is done to get the head radiograph and to determine any abnormalities or diseases of the head. This examination was performed using the grid and without grid to compare the better results of radiographs. Radiographs results were obtained using processing film, Computed Radiography (CR). This research used descriptive study conducted at Hospital Tk. II Pelamonia Makassar on January 2020. Based on the results of the research which conducted for examination of the head using grid and without grid on CR cassette obtained that the result of radiograph examination of the head using a grid was better.