Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analysis of the Use of Automatic Change Over Switch for Solar Power and PLN Electricity: Analisis Penggunaan Change Over Switch Otomatis Pembangkit Listrik Tenaga Surya dan Listrik PLN A Jamaaluddin; Ayuni, Shazana Dhya; SW, Indah Apriliana
Procedia of Social Sciences and Humanities Vol. 3 (2022): Proceedings of the 1st SENARA 2022
Publisher : Universitas Muhammadiyah Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/pssh.v3i.277

Abstract

As a follow-up step to the use of abundant solar energy sources. So efforts are made to make optimal use of solar energy. In a series of research conducted at the Electrical Power Engineering Laboratory, there are stages to realize a good Solar Power Plant. The installation of this solar power plant has its own characteristics, which at this time will be combined with PLN electricity. In the process of merging operations with PLN electricity, an automatic transfer system is needed, known as the Automatic Transfer Switch. In the Automatic Transfer Switch system, it combines the Alternating Current system as PLN electricity and in PLTS as an output inverter. This Automatic Transfer Switch has special characteristics that are able to perform the Switching process between PLN and PLTS electricity. There must be a delayed transfer time. Perfect contact and protection system. The measurement system that is displayed clearly on the system panel board becomes an important thing. It is hoped that this research will result in automatic transfer switches that are quite effective, reliable and safe in operation.
Design of Automatic Transfer Switch System Solar Power Plant – PLN Jamaaluddin, Jamaaluddin; Ayuni, Shazana Dhya; Wulandari, Indah Apriliana Sari
Journal of Electrical Technology UMY Vol. 7 No. 2 (2023): December
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.v7i2.14651

Abstract

The utilization of solar power for generating energy is increasing in scale. The Solar Power Plant (SPP) operating system comprises On Grid, Off Grid, and Hybrid systems. To successfully execute a power supply transfer operation, it is important to do thorough study. The transfer process is automated by the utilization of voltage sensors. The voltage sensing is derived from the output of both the SPP system and the PLN (Indonesian State Electricity Company) system. This study involved conducting prime SPP (Self-Paced Reading) and prime PLN (Picture Naming) tasks. The stress analysis technique is conducted during transfer in both primes. When converting SPP to PLN and transferring from PLN to SPP, voltage measurements are conducted if the SPP is in its prime state. When the power line network (PLN) is in its optimal state, voltage measurements are conducted during the transition from PLN to the solar power plant (SPP) and vice versa. When the SPP is in its prime state, the average voltage during the transfer from SPP to PLN is at 217.8 V, as indicated by the measurement findings. The average voltage for transferring power from the power grid (PLN) to the power plant (SPP) is at 225.4 V. During the peak power load period, the average voltage transferred from the power grid (PLN) to the power plant (SPP) is at 220.18 V, whereas the average value when moving from SPP to PLN is at 220.12 V. At the prime PLN, there is a minor voltage variance due to the higher stability of the PLN voltage.