Claim Missing Document
Check
Articles

Found 3 Documents
Search

Neural Networks in Optimizing the Performance of the Elliptical-Plasmonic Sensor Ramadhan, Khaikal; Syamsul, Andi M. N. F.; Marwan, Arip; Agustirandi, Beny; Yasir, Mhd; Christian, Hadi
Emerging Science Journal Vol 8, No 5 (2024): October
Publisher : Ital Publication

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.28991/ESJ-2024-08-05-07

Abstract

In this work, we report the capability of a PCF-SPR sensor with an elliptical core, which has high sensitivity, and it is explained using a machine learning approach. The sensor component consists of fused silica as the background material, TiO2 as the adhesive material between the dielectric material and the plasmonic material, and Au was chosen as plasmonic material with optimal thicknesses of 35 nm for TiO2and 45 nm for Au. Numerical results show that the sensor component has a high sensitivity of 24,000 nm/RIU for four modes that have consistent shifts, including x-polarized, x-odd, y-polarized, and y-odd. Meanwhile, AS maximums were found of -91.82 1/RIU for x-polarized, -91.88 1/RIU for y-polarized, -90.98 1/RIU for x-odd, and -89.276 1/RIU for y-odd respectively, on the refractive index of the analyte of 1,365 RIU. The ML algorithm was used to optimize the sensor parameters, and it was found that the algorithm had a very low MSE of 0.00083; this result is better than the previous report work. Doi: 10.28991/ESJ-2024-08-05-07 Full Text: PDF
Enhancing the Reliability of Photovoltaic Systems in Microgrid at Campus Area Hanadi; Christian, Hadi; Tomoyahu, Syafril; Faniama, Virara; Pradipta, Justin; Haq, Irsyad N. Haq; Leksono , Edi
Jurnal Otomasi Kontrol dan Instrumentasi Vol 16 No 1 (2024): Jurnal Otomasi Kontrol dan Instrumentasi
Publisher : Pusat Teknologi Instrumentasi dan Otomasi (PTIO) - Institut Teknologi Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.5614/joki.2024.16.1.3

Abstract

This paper assesses the reliability of photovoltaic systems within a microgrid, considering the system's operational mode and monthly data on solar radiation and load demand. The evaluation encompasses various reliability metrics, including microgrid failure rate, interruption duration, system unavailability, EENS, EIR, LOLE, and LOLP, with the objective of minimizing these parameters. The methodologies applied involve the Markov model and artificial intelligence algorithms such as Naive Bayes and Support Vector Machine (SVM). Results indicate that the microgrid exhibits enhanced reliability in an on-grid mode configuration, with a LOLP value of 0.0008. Furthermore, employing machine learning, specifically SVM, for LOLP calculation based on solar radiation yields a more precise value of 0.7245. This study offers valuable insights for policymakers and system designers in determining the optimal configuration for microgrids.
Audit Energi Menggunakan Intensitas Konsumsi Energi untuk Konservasi Energi di Gedung Kampus Faniama, Virara; Hanadi; Christian, Hadi; Tomoyahu, Syafril; Pradipta, Justin; Nashirul Haq, Irsyad; Leksono, Edi
Jurnal Otomasi Kontrol dan Instrumentasi Vol 16 No 1 (2024): Jurnal Otomasi Kontrol dan Instrumentasi
Publisher : Pusat Teknologi Instrumentasi dan Otomasi (PTIO) - Institut Teknologi Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.5614/joki.2024.16.1.6

Abstract

Energy auditing is an essential step in optimizing energy use in commercial buildings. This research explores the application of energy auditing with the Energy Consumption Intensity method to improve energy efficiency in campus buildings. Considering the changes in occupancy and activity patterns in the university environment can provide a comprehensive insight into the associated energy consumption patterns. The audit analyzed the building's energy consumption and identified potential energy savings to improve energy efficiency. Energy data was collected and analyzed to evaluate the building's energy performance. Recommended energy conservation measures include updating the lighting system, optimizing the cooling system, and improving the efficiency of equipment use. This research recommends that campus building managers adopt sustainable practices in energy management, which can lead to reduced operational costs and lower environmental impacts. Thus, the energy audit approach with the IKE method is a relevant and effective strategy for achieving energy conservation goals in the university environment. Based on the analysis, the latest IKE for Labtek V is 38.01 (2021), while the IKE for Labtek VI is 16.75 (2021), showing inefficiency of energy use in both buildings inefficient.