Analysis of Determining the Surge Arrester Protective Distance for Protection on 60 MVA Power Transformers at the 150 KV Main Substation in Surabaya Barat Reza Sarwo Widagdo; Gatut Budiono; Miftachun Nasichin
Jurnal Riset Rekayasa Elektro Vol 6, No 1 (2024): JRRE VOL 6 NO 1 JUNI 2024
Publisher : PROGRAM STUDI TEKNIK ELEKTRO

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30595/jrre.v6i1.21555

Abstract

Because it provides electrical energy to customers that require protection from lightning interference, the substation is a crucial location. An electrical equipment's defense against lightning strikes is provided by a lighting arrestor. The arrester should be placed as near to the transformer as feasible for optimal protection. In order to restrict the installation of arresters to safeguard equipment, the maximum distance for arrester installation must be established. This study only looks at one 60 MVA transformer in the Surabaya Barat Main Substation, and its goal is to determine the minimum amount of error in transformer protection. Based on the maximum possible surge arrester surge arrester jarak with a power transformer at the Surabaya Barat Main Substation, the maximum possible surge arrester distance is 8,135 meters. Based on surge arrester capability, the transformer may be protected from over voltage since the maximum voltage that can occur is just 150.83 kV, with the maximum voltage remaining below the transverse impulse drop of around 650 kV.
Analysis of The Reliability Index of The Platuk Feeder Distribution System at PT. PLN ULP Kenjeran with Section Technique Method Reza Sarwo Widagdo; Gatut Budiono; Puji Slamet; Muhammad Sultan Abdai Habibullah
Jurnal Riset Rekayasa Elektro Vol 6, No 2 (2024): JRRE VOL 6 NO 2 DESEMBER 2024
Publisher : PROGRAM STUDI TEKNIK ELEKTRO

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30595/jrre.v6i2.22920

Abstract

A high success rate is required to ensure the continuity of the supply of electricity, so that the distribution of electricity can maintain its availability continuously and have a reliable reliability value. Therefore, this study is intended to help evaluate the reliability of electric power distribution in plate feeders at PT. PLN ULP Kenjeran. The effect of failure on the system caused by equipment failure, as well as its impact on the load point will be evaluated using the section technique method. The results of the calculation show that the value of SAIFI is 2,699 times/year, SAIDI is 5.128 hours/year, and CAIDI is 1.9 hours/disturbance. Based on SPLN No. 68-2: 1986 concerning the reliability index, the value of SAIFI is 3.2 times/year, SAIDI is 21 hours/year, and CAIDI is 6.56 hours/disturbance, where the reliability index value can be categorized in accordance with SPLN standards and is considered reliable. Meanwhile, in the comparison of calculations between the section method and the method without sections, the reliability results were worse. Where the SAIFI value was 3.21112 times/disturbance (up 15.93%), the SAIDI value was 12.4056 hours/year (up 58.65%), and the CAIDI value was 3.9 hours/interruption (up 51.12%). Efforts to improve reliability by improving preventive maintenance and adding switching equipment such as LBS