ANALISIS TINDAKAN CORRECTIVE MAINTENANCE PADA MODUL OSCILLATOR PERALATAN GLIDE PATH MEREK NORMARC DI PERUM LPPNPI CABANG SURABAYA Musthofa, Luthfi
Jurnal Informatika dan Teknik Elektro Terapan Vol 12, No 3 (2024)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v12i3.4360

Abstract

Salah satu peralatan navigasi yang digunakan untuk menunjang keselamatan penerbangan adalah peralatan Instrument Landing System (ILS). ILS merupakan alat bantu pendaratan yang penting untuk meningkatkan keselamatan penerbangan. ILS menggunakan peralatan Localizer untuk memberikan panduan horizontal kepada pilot pada jarak 25 mil laut dari landasan pacu. Kemudian, peralatan glide path akan memberikan panduan vertikal kepada pilot pada jarak 10 mil laut dari landasan pacu. Dalam peralatan glide path, terdapat berbagai modul yang digunakan, salah satunya modul oscillator yang berfungsi untuk pembangkit frekuensi. Penelitian ini bertujuan untuk mengidentifikasi penyebab terjadinya alarm fail pada indikator Remote Monitoring Management (RMM) peralatan glide path yang disebabkan adanya kerusakan pada modul oscillator. Penelitian ini dilakukan dengan cara mengumpulkan data dari berbagai sumber, yaitu data primer dan sekunder. Melalui penelitian ini, ditemukan penyebab kerusakan modul oscillator yang disebabkan adanya komponen kapasitor tipe elco 100 nano farad yang terbakar akibat over voltage pada modul oscillator. 
ANALYSIS OF CORRECTIVE MAINTENANCE MEASURES OSCILLATOR MODULE GLIDE PATH NORMARC EQUIPMENT AT PERUM LPPNPI CABANG SURABAYA Musthofa, Luthfi; Toni; Irvan
Teknika STTKD: : Jurnal Teknik, Elektronik, Engine Vol 10 No 2 (2024): TEKNIKA STTKD: JURNAL TEKNIK, ELEKTRONIK, ENGINE
Publisher : Sekolah Tinggi Teknologi Kedirgantaraan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56521/teknika.v10i2.1101

Abstract

One of the navigation equipment used to support aviation safety is the Instrument Landing System (ILS). ILS is an important landing aid to improve aviation safety. ILS uses a Localizer to provide horizontal guidance to pilots at a distance of 25 nautical miles from the runway. Then, the glide path equipment will provide vertical guidance to pilots at a distance of 10 nautical miles from the runway. In glide path equipment, there are various modules used, one of which is the oscillator module which functions as a frequency generator. This study aims to identify the cause of the fail alarm on the Remote Monitoring Management (RMM) indicator of glide path equipment caused by damage to the oscillator module. This research uses a qualitative descriptive research method which emphasizes understanding problems based on natural reality namely primary and secondary data. Through this research, the cause of oscillator module damage was found to be caused by a 10,000 microfarad elco type capacitor component that burned due to over voltage on the oscillator module.
Analisis Tindakan Corrective Maintenance Pada Modul Oscillator Peralatan Glide Path Merek Normarc Di Perum LPPNPI Cabang Surabaya Prasojo, Muhamad Adimukti; Musthofa, Luthfi
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol. 8 No. 1 (2025): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Salah satu peralatan navigasi yang digunakan untuk menunjang keselamatan penerbangan adalah peralatan Instrument Landing System (ILS).  ILS merupakan alat bantu pendaratan yang penting untuk meningkatkan keselamatan penerbangan. ILS menggunakan peralatan Localizer untuk memberikan panduan horizontal kepada pilot pada jarak 25 mil laut dari landasan pacu. Kemudian, peralatan glide path akan memberikan panduan vertikal kepada pilot pada jarak 10 mil laut dari landasan pacu. Dalam peralatan glide path, terdapat berbagai modul yang digunakan, salah satunya modul oscillator yang berfungsi untuk pembangkit frekuensi. Penelitian ini bertujuan untuk mengidentifikasi penyebab terjadinya alarm fail pada indikator Remote Monitoring Management (RMM) peralatan glide path yang disebabkan adanya kerusakan pada modul oscillator. Penelitian ini dilakukan dengan cara mengumpulkan data dari berbagai sumber, yaitu data primer dan sekunder. Melalui penelitian ini, ditemukan penyebab kerusakan modul oscillator yang disebabkan adanya komponen kapasitor tipe elco 100 nano farad yang terbakar akibat over voltage pada modul oscillator.