Makdunia, Andika Iskandar
Universitas Alwashliyah Medan

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Sistem Proteksi Petir Tower Telekomunikasi di Kantor MSC PT. Smartfren Wirasari, Riza Ria; Makdunia, Andika Iskandar
Jurnal Pendidikan Tambusai Vol. 8 No. 3 (2024)
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai, Riau, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Tower BTS (Base Transceiver Station) merupakan bangunan yang tinggi dengan ketinggian minimal 25 Meter yang berfungsi sebagai penghubung antara satu BTS dengan BTS lainnya. Tower BTS dilengkapi dengan sistem proteksi eksternal dan internal yang didesign sesuai dengan Standar Nasional Indonesia. Berdasarkan standar Peraturan Umum Instalasi Listrik (PUIL) untuk menghindari bahaya sambaran petir membutuhkan nilai resistansi pentanahan sebesar <1Ω. Perangkat telekomunikasi dan Tower BTS sangat rentan mengalami kerusakan yang disebabkan oleh sambaran petir secara langsung. Pada saat tower BTS disambar petir secara langsung, maka arus lebih akan mengalir pada sistem yang berasal dari surja petir. Arus Surja petir akan terdistribusi ke saluran daya dan saluran radio yang dikoneksikan ke sistem pentanahan dengan metode bounding bar. Ada 3 sistem proteksi yang dipasang pada tower BTS yaitu Terminasi Udara (Air Terminal), Kabel Penyalur (Down Conductor) dan  Batang Elektroda (Grounding Rod).Dengan adanya sistem proteksi petir yang dipasang pada tower, perangkat akan terhindar dari sambaran petir secara langsung.
Pengukuran Total Harmonic Distortion (THD) Tegangan dan Arus di Lingkungan MATLAB Andika Iskandar Makdunia
Jurnal Manajemen Informatika & Teknologi Vol. 6 No. 1 (2026): Mei : Jurnal Manajemen Informatika & Teknologi
Publisher : LPPM Sekolah Tinggi Ilmu Ekonomi - Studi Ekonomi Modern

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51903/mifortekh.v6i1.1233

Abstract

The daily operational landscape is fundamentally dependent on electrical energy, with the nature of the electrical loads frequently exhibiting varied profiles. A notable aspect of diminished power quality is harmonic distortion, which is characterized by disturbances in the electrical waveforms of both current and voltage. These disturbances are typically engendered by the functioning of non-linear loads, such as lighting devices, computers, and air conditioning units. This pervasive condition has a detrimental impact on the quality of electrical power. It is documented that pronounced resonance disturbances have the capacity to amplify harmonics significantly, potentially by four to ten times under full load conditions. The utilization of harmonic filters represents a principal method for counteracting harmonic interference. This specific study involved the application of simulations, facilitated by the Matlab Simulink software package. The analysis of the simulation outputs revealed that the Total Harmonic Distortion (THD) for current reached an aggregate of 21.06%, while the corresponding THD for voltage was measured at 20.88%. Furthermore, the most substantial Individual Harmonic Distortion (IHD) for current was observed at the fifth harmonic order, amounting to 19.36%, and similarly, for voltage, the highest IHD was also concentrated at the fifth order, registering 20.88%.