Claim Missing Document
Check
Articles

Found 2 Documents
Search

EVALUASI KINERJA MODEL ARIMA DALAM PERAMALAN KONSUMSI ENERGI GEDUNG BERTINGKAT Yusvida, Rizka; Windarko, Novie Ayub; Setiawardhana, Setiawardhana
BRILIANT: Jurnal Riset dan Konseptual Vol 10 No 3 (2025): Volume 10 Nomor 3, Agustus 2025
Publisher : Universitas Nahdlatul Ulama Blitar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.28926/briliant.v10i3.1967

Abstract

In an effort to manage and optimize the use of energy in these buildings, the ARIMA model (Autoregressive Integrated Moving Average) emerged as a very important analytical tool. The primary objective of this research is to investigate and explore how ARIMA parameter settings can be modified to improve the accuracy of energy consumption predictions on stairwell buildings. Based on an in-depth analysis of existing literature as well as empirical data, it was found that the ARIMA model, by leveraging time row kastasioneran and the use of univariate data, showed great potential in producing highly accurate short-term predictions. In this study, it was found that by performing the correct configuration of ARIMA parameters, the model was able to a level of accuracy with MAPE of 5,317% and RMSE of 8,7. These results show an excellent level of conformity, indicating that the ARIMA model can be effectively used to improve the accuracy of prediction of energy consumption in stairwell buildings. The findings of this study confirm that with proper adjustment of parameters, ARIMA can be a very useful tool in more efficient energy management in the building sector, which can ultimately contribute to reducing unnecessary energy consumption as well as improving overall energy efficiency.
Pengaruh Variasi Suhu Kondensor terhadap Kinerja Rotary Vacuum Evaporator pada Ekstraksi Meniran (Phyllanthus Niruri) Siswantoro, Dwi Heru; Permadi, Yayang; Pradiza, Revvan Rifada; Sari, Sekar; Yusvida, Rizka
IRA Jurnal Teknik Mesin dan Aplikasinya (IRAJTMA) Vol 4 No 3 (2025): Desember
Publisher : CV. IRA PUBLISHING

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56862/irajtma.v4i3.336

Abstract

This study analyzes the effect of condenser temperature variation on the performance of a rotary vacuum evaporator (RVE) in extracting Phyllanthus niruri solution. Three condenser conditions, 23 °C, 30 °C, and without cooling, were tested, each with five replications. Observed parameters included evaporation time, mass reduction rate, energy consumption, and flavonoid content, which were analyzed statistically using Analysis of Variance (ANOVA). Results showed that the 23 °C condenser achieved the highest mass reduction rate (3.78 g/min) and the lowest energy consumption (0.14 kWh). At 30 °C and without cooling, mass reduction rates decreased to 3.02 g/min and 2.24 g/min, while energy consumption rose to 0.19 kWh and 0.20 kWh. The 23 °C condenser also produced the highest flavonoid content (11.9 mg/mL), confirming optimal thermal efficiency. This work fills the research gap on the effect of condenser temperature on energy efficiency and extract quality in RVE systems and provides a basis for developing energy-efficient evaporators for small-scale herbal industries.