Claim Missing Document
Check
Articles

Found 2 Documents
Search

Comparative Seismic Response of a Hospital Building Equipped with Lead Rubber and Friction Pendulum Bearings: Comparative Seismic Response of a Hospital Building Equipped with Lead Rubber and Friction Pendulum Bearings Yuyun Tajunnisa; Madindi Hirang; Mohamad Khoiri
IPTEK The Journal of Engineering Vol. 12 No. 2 (2026)
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j28075064.v12i2.10596

Abstract

Hospitals in active seismic regions must maintain structural safety and operational continuity after strong earthquakes. This study compares the seismic response of the Anutapura Medical Center hospital building in Palu using three support configurations: a conventional fixed base, lead rubber bearings (LRBs), and friction pendulum bearings (FPBs). A three-dimensional structural model was developed in ETABS using the as-built geometry, material properties, gravity loads, and seismic parameters prescribed by Indonesian standards. The isolated models incorporated nonlinear bearing properties obtained from the isolator design and numerical characterization. Fundamental period, lateral displacement, interstory drift ratio, horizontal seismic force, and base shear were used as comparative indicators. The fixed-base fundamental period of 1.528 s increased to 2.869 s with LRB and 2.588 s with FPB. At the base level, LRB reduced the base shear by 60.51% in the X direction and 60.89% in the Y direction, whereas FPB achieved reductions of 55.25% and 55.97%, respectively. FPB produced the smaller roof displacement, with reductions of 17.98% in X and 22.50% in Y relative to the fixed-base model; the corresponding LRB reductions were 14.44% and 17.18%. The results indicate a clear performance trade-off: LRB is preferable when reducing seismic force demand is the governing objective, while FPB provides better displacement control. These findings support performance-based selection of isolation systems for essential facilities in high-seismicity areas.
Failure Mechanism of a Rainfall-Induced MSE Wall Embankment Revealed by Two-Stage Numerical Back-Analysis Jaka Setyadi; Mohamad Khoiri; Tatas; Machsus; Moh. Muntaha
IPTEK The Journal of Engineering Vol. 12 No. 2 (2026)
Publisher : Institut Teknologi Sepuluh Nopember

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j28075064.v12i2.10737

Abstract

Rainfall infiltration is one of the main causes of embankment failure because it changes the engineering properties of soil and reduces slope stability. Conventional stability analyses commonly assume uniform soil conditions, which may not represent the actual field condition after prolonged rainfall. This study investigates the failure mechanism of an MSE wall embankment at Kedungmlati 2 Overpass, Mojokerto–Kertosono Toll Road, using a two-stage numerical back-analysis. Laboratory tests were performed on embankment soils under different degrees of saturation (Sr = 50%, 62.5%, 75%, 87.5%, and 100%) to determine the corresponding engineering properties. The numerical analyses were conducted using the finite element method implemented in PLAXIS 2D. Stage 1 evaluated six numerical models with uniform saturation conditions throughout the embankment. None of these models reproduced the observed failure mechanism. Stage 2 introduced a non-uniform saturation distribution to represent localized rainfall infiltration along the embankment slope The modified model successfully reproduced the observed failure surface. The results demonstrate that the non-uniform saturation scenario adopted in Stage 2 provided a closer agreement with the observed failure mechanism than the uniform saturation scenarios evaluated in Stage 1. In this scenario, a saturated near-surface zone and a relatively unsaturated embankment core were assigned as part of the back-analysis procedure to reproduce the observed failure pattern. The proposed rehabilitation measures further increased the safety factor from 1.085 to 1.765, effectively restoring embankment stability. These findings suggest that considering spatial variations in the degree of saturation can provide a more representative prediction of rainfall-induced failure mechanisms than assuming a uniform saturation distribution. The novelty of this study lies in the proposed practical back-analysis approach, which combines a non-uniform saturation scenario with experimentally determined shear strength parameters at different degrees of saturation to reproduce the observed failure mechanism and evaluate rehabilitation strategies for MSE wall embankments without explicitly modeling transient seepage.