Wahana Teknik
Vol 1 No 1 (2012): Wahana Teknik

PERENCANAAN INSTALASI POMPA RETURN PUMP DENGAN KAPASITAS 130 M3/JAM UNTUK EXCHANGER HEATER AMONIA

Wardjito Wardjito (Universitas Gresik)



Article Info

Publish Date
10 Jan 2012

Abstract

The use of pumps in an industry is very much its role in accordance with the functions and needs, as well as the main means of production process, as well as a means of supporting the production process. Return Pump Pump Ammonia Recycle Water Heater Exchanger absolutely necessary on a heater exchanger design Ammonia in Utility Plant X in Gresik, because the pump is an integral part of the exchanger unit heater itself, so the function of the heater can work properly is to change the temperature of the ammonia of of -33 0C  - -10 0C. Exchanger heater design capacity 55 tons / hour, requires a return pump with a pump capacity of 130 m3/hr. From the calculation results, obtained, Head Pump: 11.25 m, pump efficiency: 76%, 1500 rpm, impeller types: closed, the pipe diameter: 6“, the pump pressure, 2.1 kg/cm2, the diameter of shaft: 35 mm, nominal motor power: 5.36 hp. Keywords : Return Pump, Heater, Exchangers, Ammonia

Copyrights © 2012






Journal Info

Abbrev

WahanaTeknik

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Engineering Mechanical Engineering

Description

Wahana Teknik merupakan wadah publikasi ilmiah yang menyajikan hasil-hasil penelitian berupa makalah terkait bidang Teknik Mesin dan Teknik Sipil. Jurnal Wahana Teknik diterbitkan oleh Fakultas Teknik Universitas Gresik. Pada tahun 2017 jurnal Wahana Teknik terbit berkala dua kali per tahun. Makalah ...