The Jurnal Arsip Rekayasa Sipil dan Perencanaan (Journal of Archive in Civil Engineering and Planning)
Vol 1, No 4 (2018): Jurnal Arsip Rekayasa Sipil dan Perencanaan

ANALISIS KOMPARASI RASIO KAPASITAS KOLOM GEDUNG BERTINGKAT RENDAH PADA 23 KABUPATEN DI PROVINSI ACEH BERDASARKAN SNI 03-1726-2002 DAN SNI 03-1726-2012

Fakhrurrazi Fakhrurrazi (Magister Teknik Sipil, Fakultas Teknik, Universitas Syiah kuala, Banda Aceh)
Taufik Saidi (Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah kuala, Banda Aceh)
Muttaqin Muttaqin (Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah kuala, Banda Aceh)



Article Info

Publish Date
09 Dec 2018

Abstract

In 2002, through the national standardization agency, the Indonesian government issued SNI 03-1726-2002 on Earthquake Resilience Planning Standard for Building Structure to anticipate the effects of earthquake on building. However, after the standard has been issued there have been several other major earthquakes that rendered it necessary to revise the existing standards. Therefore, in 2012 the government issued SNI 03-1726-2012 on Procedures for Earthquake Resistance Planning for Building and Non Building Structures. When viewed from both these standards, it can be seen that Aceh province is one of the provinces with high earthquake intensity so it is necessary to do a research to observe the effect of changes of both standards to the ratio of column capacity and minimum reinforcement requirements for buildings constructed in Aceh province. Based on the results of the research, the average column capacity ratio against the load in SNI 03-1726-2012 has increased by 45.02% and the average minimum reinforcement requirement available is only 54.5%. The increase is due to an increase in primacy factor from 1.0 to 1.5, causing increased structural load. In addition, there was an increase in the combined burden in the form of 30% additional redundant factors as well as the addition of earthquake load due to an increase in rock bed acceleration factors in some regencies. Thus it can be concluded that the building under review has not fulfilled the requirements of SNI 03-1726-2012 and is recommended for planning by adding a shear wall to reduce the structural load.

Copyrights © 2018






Journal Info

Abbrev

JARSP

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Transportation

Description

The Jurnal Arsip Rekayasa Sipil dan Perencanaan (Journal of Archive in Civil Engineering and Planning) is a peer-reviewed journal published four times a year (March, June, September, and December) that publishes reviewed articles which contribute new results in all areas of the Civil Engineering and ...