Lowland Technology International
Vol 21 No 1, June (2019)

Environmental risk assessment and protection measures due to dewatering during construction of Wangfuzhuang Metro Station, Jinan, China

G. Li (Unknown)
B. Hu (Unknown)
L. Lu (Unknown)
J. Chen (Unknown)



Article Info

Publish Date
06 Jun 2019

Abstract

Jinan is famous due to its spring group with rich groundwater resources. The groundwater system should be protected during the construction of the metro system. This paper presents a case study of the environmental risk assessment due to dewatering and recharges during the construction of Wangfuzhuang Metro Station, Jinan, China. The Fuzzy Analytic Hierarchy Process (FAHP) is employed to evaluate the impact on the environment. Moreover, based on Darcy’s law, and water inflow calculations for a submersible full well and water level line equation under the coupling action of a submersible full dewatering-recharge well group, the dewatering and recharge schemes of the deep foundation pit excavation are designed. Both results from numerical simulation and site survey show that dewatering and recharging at the Jinan R1 line site were effective in environmental protection.

Copyrights © 2019






Journal Info

Abbrev

ialt_lti

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Engineering Transportation

Description

The Lowland Technology International Journal presents activity and research developments in Geotechnical Engineering, Water Resources Engineering, Structural Engineering, Transportation Engineering, Urban Planning, Coastal Engineering, Disaster Prevention and Mitigation ...