JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA
Vol. 8 No. 2 (2021): JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA

The Short Form-6 Dimension (SF-6D) Validity and Reliability in Hemodialysis Patients

Anisa Zulfa Fatihah (Program Studi Magister Farmasi Klinik, Fakultas Farmasi, Universitas Gadjah Mada, Yogyakarta)
Tri Murti Andayani (Departemen Farmakologi dan Farmasi Klinik, Fakultas Farmasi, Universitas Gadjah Mada, Yogyakarta)
Nanang Munif Yasin (Departemen Farmakologi dan Farmasi Klinik, Fakultas Farmasi, Universitas Gadjah Mada, Yogyakarta)



Article Info

Publish Date
29 Aug 2021

Abstract

Background: Quality of life becomes an important parameter that is needed for assessing the clinical outcome of patients undergoing long-term therapy for chronic diseases, such as chronic kidney failure. Short Form-6 Dimension (SF-6D) is one of the generic instruments that can be used to assess health-related quality of life (HRQOL). The psychometric properties SF-6D test in hemodialysis patients in Indonesia has never been conducted. Objective: Aimed to evaluate the reliability and validity of SF-6D questionnaire in Indonesian version in patients with chronic kidney failure. Methods: This is an observational study with a cross-sectional design involving 117 patients who meet the inclusion and exclusion criteria in the hemodialysis unit in Dr. Sardjito Central General Hospital and UGM Academic Hospital Yogyakarta. Results: The SF-6D questionnaire has good internal consistency, as seen in Cronbach's alpha value of 0.771. In this study, the ceiling effect test showed 6.8% (< 15%). The measurement of convergent validity was carried out using Spearman rho to analyze the correlation of the questionnaires and see its correlation with other instruments (KDQOL-SF36). Based on the research, the correlation coefficient value of 0.768 (> 0.75) indicates very good result for a strong correlation. The SF-6D instrument was able to distinguish the quality of life with a significant value (p < 0.05) in age, occupation, and comorbid groups. Conclusion: SF-6D questionnaire is valid and reliable, so it can be used to measure the HRQOL of hemodialysis patients. The mean SF-6D utility score of hemodialysis patients is high (0.7975 ± 0.1488).

Copyrights © 2021






Journal Info

Abbrev

JFIKI

Publisher

Subject

Chemistry Education Health Professions Medicine & Pharmacology Other

Description

Jurnal ini adalah jurnal peer-review nasional, yang diterbitkan dua kali dalam membahas tentang topik-topik hasil penelitian di bidang pelayanan dan praktik kefarmasian, konsultasi masyarakat, teknologi kefarmasian serta disiplin ilmu kesehatan yang terkait dengan erat. Jurnal ini memfokuskan pada ...