Abstract

Scales Scales in the world of health are used to measure human body weight such as baby scales. Newborns are very important to be weighed because it is used as a measure of the baby's health indication ranging from 2.4 kg to 4.2 kg. The author makes a tool for this to make it easier for users to weigh with a 7 segment display on the Infant Warmer tool and external calibration. By using a loadcell sensor with a maximum capacity of 5 kg, the loadcell can detect the weight of the load where the voltage generated by the loadcell of 0.7 mV at a load of 1 kg is amplified to 0.62 V by the PSA circuit using the AD620 IC and then processed by Arudino UNO as a microcontroller. The weight results will be displayed on the 7Segment display located on the Infant Warmer tool. In the study, the measured load included a weight of 0 kg to a maximum weight of 5 kg. The measurement of the data results was carried out 5 times each by comparing the modules that had been made with the standard weight, namely (lead). The data from the measurement results of the research module shows that when the weight of the measurement at 1 kg has an error percentage of 0.08%. Measurements at a weight of 2 kg have an error percentage of 0.05%. Measurement of weight 3 kg has a presentation error of 0.01%. Measurements at a weight of 4 kg have a presentation error of 0.02%. And measurements at a weight of 5 kg have an error percentage of 0.04%. Then the data from the measurement results of the research module shows the largest error presentation of 0.08% at a weight of 1 kg. And the data from the measurement results of the research module shows the smallest error presentation of 0.01% at a weight of 3 kg. Making a research module in the form of a scale placed on an infant warmer can make it easier for the wearer.

Copyrights © 2021






Journal Info

Abbrev

Teknokes

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Engineering

Description

The JURNAL TEKNOKES is a peer-reviewed periodical scientific journal aimed at publishing research results of the medical engineering areas. The Journal is published by the Department of Medical Electronics Technology, Health Polytechnic of Surabaya, Ministry of Health Indonesia. The role of the ...