Jurnal Chemurgy
Vol 6, No 2 (2022): Jurnal Chemurgy-Desember 2022

ANALYSIS OF PUMP INSTALLATION DESIGN FOR CLEAN WATER IN PT PAMAPERSADA NUSANTARA, INDO DISTRICT - BONTANG, EAST KALIMANTAN

Moh. Arif Batutah (Universitas Muhammadiyah Surabaya)
Hairul Huda (Universitas Mulawarman)



Article Info

Publish Date
25 Dec 2022

Abstract

The demand for clean water by company employees who live in barracks is changing. This change in direction also affects the distribution of clean water, which will impact the effectiveness of the plumbing and pump systems. This analysis aims to know the plumbing installation and selection of the right pump so it can operate optimally. The method used is the analysis by ignoring losses, such as friction losses between the working fluid and the equipment. This analysis also calculates head, capacity, pump power, and efficiency. From the calculation result, we conclude that the flow capacity is 2,643 m3/min, and the total head installation is 71,69 m. So, a centrifugal pump with rotation 2951 rpm, type Groundfos CRN 90 4-2, is the best pump for installation. Keywords: pump, head installation, pump power, efficiency, capacity 

Copyrights © 2022






Journal Info

Abbrev

TK

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Control & Systems Engineering Energy Engineering Environmental Science

Description

Jurnal Chemurgy is published by Department of Chemical Engineering, Engineering Faculty, University of Mulawarman. This journal dedicated to the topics that relevant to Chemical Engineering, such as Energy, Thermodynamics, Optimization Process & Sustainable Process, Process Control, Material ...