Indonesian Journal of Chemistry
Vol 23, No 5 (2023)

Development of a Rapid and Sensitive Probe for Colorimetric Detection of Ni2+ Ion in Water Sample by β-Cyclodextrin Stabilized Silver Nanoparticles

Farrah Nurkhaliza (Research Centre for Chemistry, National Research and Innovation Agency (BRIN), Kawasan Puspiptek, Building 452, Serpong, Banten 15314, Indonesia
Department of Chemistry, Syarif Hidayatullah State Islamic University, Jl. Ir. H. Djuanda No. 95, Ciputa)

Ahmad Fathoni (Department of Chemistry, Syarif Hidayatullah State Islamic University, Jl. Ir. H. Djuanda No. 95, Ciputat, Banten 15412, Indonesia)
Muhammad Eka Prastya (Research Centre for Pharmaceutical Ingredients and Traditional Medicine, National Research and Innovation Agency (BRIN), Kawasan Puspiptek, Building 466, Serpong, Banten 15314, Indonesia)
Zetryana Puteri Tachrim (Research Centre for Pharmaceutical Ingredients and Traditional Medicine, National Research and Innovation Agency (BRIN), Kawasan Puspiptek, Serpong, Banten 15314, Indonesia)
Abdul Aji (Department of Chemistry, Institut Teknologi Sumatera, Jl. Terusan Ryacudu, Jati Agung, Lampung 35365, Indonesia)
Agustina Sus Andreani (Research Centre for Chemistry, National Research and Innovation Agency (BRIN), Kawasan Puspiptek, Building 452, Serpong, Banten 15314, Indonesia)



Article Info

Publish Date
16 Oct 2023

Abstract

A rapid and selective colorimetric detection of Ni2+ was developed using silver nanoparticles (AgNPs) with β-cyclodextrin (β-CDs) as reducing and stabilizing agents. Characterization was assessed by spectrophotometer UV-vis, Fourier transform infra-red (FTIR), transmission electron microscopy (TEM), and particle size analyzer (PSA). The AgNPs-β-CDs were relatively stable after being stored for 5 months. The addition of Ni2+ to the AgNPs-β-CDs shifted the surface plasmon resonance (SPR) band at 409 nm. Synthesized AgNPs-β-CDs had a spherical shape and an average size of 25.07 ± 0.66 nm (analyzed by TEM) and 33.63 ± 0.25 nm, as confirmed by PSA. AgNPs-β-CDs as colorimetric sensors for Ni2+ ions had a good linear calibration curve at 409 nm with the R2 value of 0.9993. The limit of detection (LoD) was found to be 33.30 ppb, while the limit of quantification (LoQ) was 111.0 ppb. This sensor had been applied to a seawater sample from Ancol Beach, North Jakarta, Indonesia and it exhibited good precision and accuracy. In this work, β-CDs-synthesized AgNPs were able to detect Ni2+ ions and were beneficial as an alternative method for Ni2+ screening in environmental samples.

Copyrights © 2023






Journal Info

Abbrev

ijc

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Chemistry

Description

Indonesian Journal of Chemistry is an International, peer-reviewed, open access journal that publishes original research articles, review articles, as well as short communication in all areas of chemistry including applied chemistry. The journal is accredited by The Ministry of Research, Technology ...