JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA
Vol. 10 No. 3 (2023): JURNAL FARMASI DAN ILMU KEFARMASIAN INDONESIA

Development of Colloidal Silver-based Mercury Sensors in Whitening Cream

Muhammad Hilmi Afthoni (1Department of Pharmacy, Faculty of Science and Technology, Machung University, Malang, Indonesia 2Department of Clinical and Community Pharmacy, Faculty of Pharmacy, University of Jember, Jember, Indonesia)
Sherly Yunita (Department of Pharmacy, Faculty of Science and Technology, Machung University, Malang, Indonesia)
Eva Monica (Department of Pharmacy, Faculty of Science and Technology, Machung University, Malang, Indonesia)



Article Info

Publish Date
21 Dec 2023

Abstract

Background: Mercury, a hazardous heavy metal known for its toxicity to the human body, finds application in cosmetics due to its capacity to inhibit melanin formation. Traditional mercury analysis relies on resource-intensive and time-consuming instrumentation. Objective: This study aims to devise cost-effective and practical sensors for mercury detection. Methods: The sensor development process involves immobilizing the sensor onto paper, reacting it with mercury, scanning the outcome using a scanner, and subsequently quantifying RGB values using the ImageJ software. Results: Optimization of reagent concentrations gave a ratio of methylene blue, AgNO3, gallic acid, and ascorbic acid at 0.5:7:1.5:1 generating the best results. Additionally, pH optimization within the range of 5 to 9 demonstrates stability without necessitating the inclusion of a buffer solution. Notably, the blue variant exhibits superior responsiveness during concentration optimization. Characterization of the sensor reveals a response time of 3 minutes and minimal interference of 2.145% from other substances. The sensor exhibits a linearity range of 0.5-250 ppm, regression equation y = 8.603x + 21.124, an R-value of 0.994, and an exceedingly low p-value of 6.9924589548512 x 10-9. The sensor boasts a limit of detection (LOD) of 0.206 and a limit of quantification (LOQ) of 0.265, indicative of its precision. Further assessments reveal a percent relative standard deviation (% RSD) precision of 2.017% and a recovery rate of 96.14%. Conclusion: The sensor has exhibited stability for over one month under room temperature storage conditions. A comparison between the UV-Vis spectrophotometer and the sensor signifies no significant difference between the two methods.

Copyrights © 2023






Journal Info

Abbrev

JFIKI

Publisher

Subject

Chemistry Education Health Professions Medicine & Pharmacology Other

Description

Jurnal ini adalah jurnal peer-review nasional, yang diterbitkan dua kali dalam membahas tentang topik-topik hasil penelitian di bidang pelayanan dan praktik kefarmasian, konsultasi masyarakat, teknologi kefarmasian serta disiplin ilmu kesehatan yang terkait dengan erat. Jurnal ini memfokuskan pada ...