Assessment of Power System Equipment to Enhance the Power Quality at Dr. Saiful Anwar General Hospital Malang

Reza Sarwo Widagdo (Universitas 17 Agustus 1945 Surabaya)
Puji Slamet (Universitas 17 Agustus 1945 Surabaya, Indonesia)
Aris Heri Andriawan (Universitas 17 Agustus 1945 Surabaya, Indonesia)
Balok Hariadi (Universitas 17 Agustus 1945 Surabaya, Indonesia)
Izzah Aula Wardah (Universitas 17 Agustus 1945 Surabaya, Indonesia)
Elvianto Dwi Hartono (Universitas 17 Agustus 1945 Surabaya, Indonesia)



Article Info

Publish Date
17 Apr 2024

Abstract

Electrical conditions in the operations building and substation of the regional general hospital Dr. Saiful Anwarexperienced a power cut at optimum load, resulting in the power supply being solely obtained from the generator. The aim of the assessment carried out was to delve deeper into power quality, electrical performance, and other supporting equipment to maximize service to patients based on the assessment findings. The assessment stages utilized were the initial assessment stage and the detailed assessment stage. The analysis stages were conducted under steady-state load conditions. The assessment process involved field measurements, observations, and interviews with technical staff at the general hospital Dr. Saiful Anwar. Field measurements utilized Ammeters, Voltmeters, and Harmonic Analyzers to ascertain voltage imbalances, current imbalances, and harmonic content in SDP panels on each floor of the operations building, as well as to evaluate UPS components as backup power and stabilizers for electrical equipment. The results of observations and direct measurements in the field revealed several issues, including a current harmonic content of up to 50% on the 6th floor of the operations building (OK6) and in the Linac room, along with various other findings related to voltage and current imbalances in the secondary substation and certain components. The UPS, alike to the battery and filter capacitor inside, requires replacement. Additionally, regarding the grounding value, which currently stands at 3 Ohms, it is imperative to incorporate a parallel grounding system to bring the value below 1 Ohm to mitigate the risk of leakage current occurrences.

Copyrights © 2024






Journal Info

Abbrev

bernas

Publisher

Subject

Religion Agriculture, Biological Sciences & Forestry Humanities Dentistry Education Environmental Science Languange, Linguistic, Communication & Media Mathematics Neuroscience Nursing Public Health Social Sciences Veterinary Other

Description

The aim of this journal publication is to disseminate the conceptual thoughts or ideas and research results that have been achieved in the area of community services. Bernas: Jurnal Pengabdian Kepada Masyarakat, particularly focuses on the main problems in the development of the sciences of ...