Jurnal Karajata Engineering
Vol. 3 No. 2 (2023): 2023

PENGARUH UKURAN BUTIR AGREGAT KASAR TERHADAP KAPASITAS KUAT TEKAN DAN NILAI SLUMP BETON POROUS

Samsul, Samsul (Unknown)
Mustakim, Mustakim (Unknown)
Kasmaida, Kasmaida (Unknown)



Article Info

Publish Date
11 Dec 2023

Abstract

Porous concrete is an innovation and development solution for parking areas, yards and pedestrian areas, as a way to avoid standing water or even flooding. The purpose of this study was to determine the proportion of the optimum coarse aggregate mixture for porous concrete in terms of compressive strength and slump value. The research method used was experimental research conducted at the Laboratory of Structures and Materials, Muhammadiyah Parepare University. The results of this study can indicate that the optimum mixture proportions were obtained at aggregate variations of 0.5-1 cm. The compressive strength with an aggregate size of 0.5-1 cm is 6.13 MPa, an aggregate size of 1-2 cm is 5.47 MPa, while an aggregate size of 2-3 cm is 5.00 MPa. The slump value with an aggregate size of 0.5-1 cm is 196 mm, an aggregate size of 1-2 cm is 192 mm, while an aggregate size of 2-3 cm is 178 mm.

Copyrights © 2023






Journal Info

Abbrev

karajata

Publisher

Subject

Civil Engineering, Building, Construction & Architecture

Description

JURNAL KARAJATA ENGINEERING adalah jurnal ilmiah pada bidang Teknik Sipil yang diterbitkan oleh Fakultas Teknik Universitas Muhammadiyah Parepare. Jurnal KARAJATA ENGINEERING berisi tulisan yang diangkat dari hasil penelitian pada bidang Teknik Sipil yang mencakup bidang penelitian Struktur, ...