Jurnal Bahari dan Teknologi (BARTEK)
Vol 1 No 1 (2025): Jurnal Bahari dan Teknologi [BARTEK]

Analisis Penyebab Terjadinya Kebocoran Kondensor pada Mesin Pendingin Ruangan di MV.Federal Oak

Bima Wardana (Politeknik Ilmu Pelayaran Semarang)
Andy Wahyu Hermanto (Politeknik Ilmu Pelayaran Semarang)
Anicitus Agung Nugroho (Politeknik Ilmu Pelayaran Semarang)



Article Info

Publish Date
20 Feb 2025

Abstract

The air conditioning system in a room monitors the regulation of humidity and air temperature, with a focus on providing optimal levels of comfort for the ship's crew, thereby reducing fatigue and helping to improve fitness. Problems can arise and the vessel can be disrupted if maintenance schedules are not followed. Based on the researcher's experience during sea practice for 12 months on an MV ship. Federal Oak. When the ship entered summer and entered Mexico, the condenser leaked in the air conditioning engine, which disturbed the comfort of the ship's crew while working. This research aims to identify the causes, consequences, and solutions for condenser leaks in air conditioning systems. This research uses a qualitative description approach that uses Fishbone data analysis to organize and identify the factors that cause certain effects, then separate the root causes of the problem. This study found that deposits in the condenser pipe and air in the condenser are the causes of AC machine condenser leaks, dirty cooling water results in a decrease in the amount of freon that is condensed, and lack of maintenance and supervision will worsen the condition of the components. The impact of a condenser leak in an air conditioning machine is that room temperature cannot be reached because the freon, which should be converted into a liquid when it enters the condenser, actually experiences a shortage due to a leak that occurs in the condenser and a decrease in engine performance. Efforts to overcome leaks in air conditioning machine condensers include using a brush to clean dirt stuck to the capillary pipes and spraying water into the condenser pipes. Turn off the air conditioning machine and weld pipe joints that are leaking. Clean the condenser tube using a long iron. Carry out maintenance in accordance with the Plan Maintenance System.

Copyrights © 2025






Journal Info

Abbrev

bartek

Publisher

Subject

Control & Systems Engineering Electrical & Electronics Engineering Engineering Materials Science & Nanotechnology Mechanical Engineering

Description

Jurnal Bahari dan Teknologi (BARTEK) merupakan jurnal pelayaran / jurnal maritim yang diperuntukkan untuk publikasi artikel hasil penelitian ataupun kajian ilmiah. Jurnal ini diperuntukkan untuk bidang ilmu NAUTIKA, TEKNIKA, Permesinan Kapal, Operasional Kapal, Kelistrikan, system kontrol. Terbit ...