The problem faced by the Bmrsign Wallgallery company is that products are found that do not match the specifications set by the company. The types of product damage are wrong size frames, broken frames, and uneven corners. To solve this problem, the SQC method is used to reduce the causes of defects in the product. The purpose of this method is to reduce the risk of damage to the product. The object studied was Bmrsign Wallgallery with a sample of 29 days. The use of the SQC method is accompanied by analysis tools in the form of control charts (p-charts), Pareto diagrams, cause and effect diagrams (fishbone). Based on the results of data analysis implementing the Statistical Quality Control (SQC) method using the P-Chart control map, the largest value of the Upper Control Limit (UCL) can be shown as 0.272, while the Lower Control Limit (LCL) is -0.013. The results show that the number of defective products during the frame making process is still within normal control limits. The analysis using the Pareto diagram shows that the types of frame defects are dominated by broken with a percentage of 35% or a total of 66 pcs, inappropriate size shapes as much as 33% or a total of 62 pcs, and uneven corners as much as 32% or a total of 60 pcs. Based on the results of the fishbone diagram analysis, defective products are caused by workers who are not focused, work standards are not adhered to, machine maintenance is not given attention, and there is a decrease in the quality of raw materials.
Copyrights © 2024