Jurnal Pensil : Pendidikan Teknik Sipil
Vol. 15 No. 2 (2026): Jurnal Pensil : Pendidikan Teknik Sipil

ANALYSIS OF THE EFFECT OF FOUNDATION DIMENSIONS ON THE BEARING CAPACITY AND SETTLEMENT OF PILE FOUNDATIONS FOR THE WTP SPAM KOBEMA BENGKULU BUILDING

Nurhaliza (Department of Civil Engineering, Faculty of Engineering, Bengkulu University, W.R. Supratman Rd No. 2 Kandang Limun, Muara Bangkahulu, Bengkulu 38371, Indonesia)
Raihanah Naura Jinan (Department of Civil Engineering, Faculty of Engineering, Bengkulu University, W.R. Supratman Rd No. 2 Kandang Limun, Muara Bangkahulu, Bengkulu 38371, Indonesia)
Rena Misliniyati (Department of Civil Engineering, Faculty of Engineering, Bengkulu University, W.R. Supratman Rd No. 2 Kandang Limun, Muara Bangkahulu, Bengkulu 38371, Indonesia)
Hardiansyah (Department of Civil Engineering, Faculty of Engineering, Bengkulu University, W.R. Supratman Rd No. 2 Kandang Limun, Muara Bangkahulu, Bengkulu 38371, Indonesia)
Muharram Nur Fikri (Department of Civil Engineering, Faculty of Engineering, Bengkulu University, W.R. Supratman Rd No. 2 Kandang Limun, Muara Bangkahulu, Bengkulu 38371, Indonesia)
Khairul Amri (Department of Civil Engineering, Faculty of Engineering, Bengkulu University, W.R. Supratman Rd No. 2 Kandang Limun, Muara Bangkahulu, Bengkulu 38371, Indonesia)



Article Info

Publish Date
31 May 2026

Abstract

The Water Treatment Plant (WTP) in the Benteng Kobema Bengkulu Regional Drinking Water Supply System (SPAM), with a capacity of 380 Litres per Second, plays a crucial role in providing clean water to the community. This study aims to analyse the influence of dimensional variations on the bearing capacity and foundation settlement of the WTP building using the Poulos and Davis method, the Reese and Wright method, the Luciano Decourt method, and the finite element method. Based on the results of the Standard Penetration Test (SPT), the influence of variations in shape, namely square with dimensions of 300 mm, 400 mm, and 500 mm, as well as depths of 7m, 9m, 11m, and 13m, affects the bearing capacity and foundation settlement This analysis compares the results of bearing capacity calculations and pile foundation settlement in WTP buildings using several different methods. The analysis results show that the bearing capacity, deflection magnitude, and smallest settlement are below the permitted settlement limit, i.e., less than 10% of the foundation dimensions. The comparison between static and numerical methods, or the Bearing Capacity Ratio (BCR) approaching 1, is more efficient and safer. In this analysis, the BCR value closest to 1 was obtained for a 500 mm foundation using the Reese and Wright method at a depth of 9 m, yielding a bearing capacity of 312.04 tonnes for a single pile and 207.69 tonnes for a pile group.

Copyrights © 2026






Journal Info

Abbrev

jpensil

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Education Other

Description

In general, the Jurnal Pensil : Pendidikan Teknik Sipil accepts manuscripts with the themes: Education Strategy and Management, Industrial Relations, and Civil and Structural Engineering. Jurnal Pensil : Pendidikan Teknik Sipil is intended for all academics in Civil Engineering Vocational Education. ...