Biodiversitas Journal of Biological Diversity
Vol. 26 No. 12 (2025)

Phytoremediation efficiency of Crinum asiaticum in enclosed spaces based on morphological traits and CO absorption dynamics

KHAMBALI KHAMBALI (Department of Environmental Health, Politeknik Kesehatan Kemenkes Surabaya. Jl. Pucang Jajar Tengah No. 56, Surabaya 60282, East Java, Indonesia)
ELSIE TANISHA DENANDA (Department of Environmental Health, Politeknik Kesehatan Kemenkes Surabaya. Jl. Pucang Jajar Tengah No. 56, Surabaya 60282, East Java, Indonesia)
RUSMIATI RUSMIATI (Department of Environmental Health, Politeknik Kesehatan Kemenkes Surabaya. Jl. Pucang Jajar Tengah No. 56, Surabaya 60282, East Java, Indonesia)
DEMES NURMAYANTI (Department of Environmental Health, Politeknik Kesehatan Kemenkes Surabaya. Jl. Pucang Jajar Tengah No. 56, Surabaya 60282, East Java, Indonesia)
IVA RUSTANTI ERI WARDOYO (Department of Environmental Health, Politeknik Kesehatan Kemenkes Surabaya. Jl. Pucang Jajar Tengah No. 56, Surabaya 60282, East Java, Indonesia)
SLAMET WARDOYO (Department of Environmental Health, Politeknik Kesehatan Kemenkes Surabaya. Jl. Pucang Jajar Tengah No. 56, Surabaya 60282, East Java, Indonesia)



Article Info

Publish Date
01 Jan 2025

Abstract

Abstract. Khambali, Denanda ET, Rusmiati, Nurmayanti D, Wardoyo IRE, Wardoyo S. 2025. Phytoremediation efficiency of Crinum asiaticum in enclosed spaces based on morphological traits and CO absorption dynamics. Biodiversitas 26: 6205-6211. Indoor air pollution, particularly carbon monoxide (CO), poses a serious health risk in poorly ventilated environments. This study evaluates the phytoremediation potency of Crinum asiaticum, a native ornamental species, in reducing indoor CO concentrations—an area with limited prior investigation. A quasi-experimental design was employed using a 1.2 m × 0.9 m × 0.7 m test chamber, into which CO gas sourced from a 110 cc petrol-powered motorcycle was introduced. Five groups were assessed: one control (no plants) and four treatment groups containing one to four C. asiaticum specimens. CO levels were measured before and 45 minutes after exposure using a calibrated gas detector. Descriptive analysis revealed a dose-dependent reduction in CO levels, with the T4 group achieving the greatest decrease of 28.40%. The T3 and T2 groups treatments reduced concentrations by 14.59% and 7.34%, respectively. The T1 group showed a modest reduction of 4.47%, indicating limited absorption capacity at minimal biomass. The Kruskal-Wallis test indicated significant differences among groups (p<0.001), confirming a positive correlation between plant quantity and CO absorption capacity. Although final CO concentrations remained above national indoor air quality standards, the findings underscore the potential of C. asiaticum as a natural biofilter. Its integration into indoor environments not only supports air remediation but also enhances biodiversity through the use of indigenous phytoremediator species. This study presents a novel, eco-friendly approach to mitigating indoor air pollution and advancing environmental health strategies.

Copyrights © 2025






Journal Info

Abbrev

biodiv

Publisher

Subject

Agriculture, Biological Sciences & Forestry Biochemistry, Genetics & Molecular Biology

Description

The Biodiversitas Journal was first published in 2000 by the Department of Biology, FMNS, Universitas Sebelas Maret, Surakarta, Indonesia, then in 2006 it was co-published by the Society for Indonesian Biodiversity and that department; since 2017 it was also hosted by Smujo. From 2003-2012 it was ...