Closed-house broiler operations require timely environmental information, but discontinuous data collection and sensor behaviour after device restarts can affect field IoT measurements. This study evaluated PANDORA, a locally hosted system for high-frequency monitoring of an ammonia-sensitive sensor response, temperature, and relative humidity in a commercial broiler house. An ESP32 transmitted nominal 5-s measurements through the farm’s Wi-Fi network to a local server, PostgreSQL database, and rowser dashboard. Deployment spanned two production cycles of approximately 19,000 birds each, whereas quantitative analysis used 3,225 firmware-consistent observations from three discrete Cycle 2 monitoring windows. All retained records contained complete environmental fields and unique identifiers, and the median within-segment interval was 5 s. The median firmware-derived NH? value was 17.65 in firmware-reported ppm units. Session-aware analysis identified a major measurement limitation: all 80 values above 30 occurred within the first 111 s of a new firmware session, whereas 2,853 observations recorded more than 120 s after session start had a median of 17.45 and a maximum of 29.25. Consequently, we could not distinguish two session-start values above 60 from restart-related sensor behaviour, and we did not interpret them as ventilation effects. PANDORA demonstrated local acquisition, storage, and visualization under field conditions while showing that reference-grade calibration, startup gating, and auditable operator-response logs are required before threshold-based operational decisions. Contribution to Sustainable Development Goals (SDGs):SDG 9: Industry, Innovation, and InfrastructureSDG 2: Zero HungerSDG 3: Good Health and Well-beingSDG 12: Responsible Consumption and Production
Copyrights © 2027