Jurnal Listrik, Instrumentasi, dan Elektronika Terapan
Vol 7, No 2 (2026)

Implementation of YOLOv5 for Fingerling Detection under Turbid Conditions in Abandoned Tin Mining Ponds

Indra Dwisaputra (Politeknik Manufaktur Negeri Bangka Belitung)
Sirlus Andreanto Jasman Duli (Politeknik Manufaktur Negeri Bangka Belitung)
Eko Sulistyo (Politeknik Manufaktur Negeri Bangka Belitung)
Evvin Faristasari (Politeknik Manufaktur Negeri Bangka Belitung)
Ali Rospawan (National Chung Hsing University, Politeknik Manufaktur Negeri Bangka Belitung)
Fadillah Aslammy Pratama Sayti (Politeknik Manufaktur Negeri Bangka Belitung)
Muhammad Putra Deswalki (Politeknik Manufaktur Negeri Bangka Belitung)



Article Info

Publish Date
30 Oct 2026

Abstract

The utilization of abandoned tin mining ponds for freshwater aquaculture in Bangka Belitung requires reliable monitoring technology, particularly for fingerling counting under variable water clarity conditions. Because in-situ underwater counting within large, deep, and unconfined pond waters is technically impractical, this study developed an on-bank portable inspection station integrating YOLOv5-based image processing on an embedded Raspberry Pi unit with multi-point turbidity sensing using water extracted directly from abandoned tin mining ponds. A dataset of 80 original images was strictly partitioned prior to augmentation into training (70%), validation (20%), and independent test (10%) sets to ensure zero data leakage, followed by training set expansion to 225 images via offline augmentations. Trained at 640×640 resolution across 50 epochs, the YOLOv5 model achieved 98% accuracy, 100% precision, 96% recall, 100% specificity, and an F1-score of 0.98 at an IoU threshold of 0.5. While vision-only detection remained stable at low densities, severe under-counting (up to 26%–30% loss) occurred under high-density conditions (40–50 fingerlings) when turbidity exceeded 85 NTU due to light scattering and boundary occlusion. To address this limitation, an Adaptive Turbidity Correction Factor (α = 1.36) was introduced, successfully restoring biomass estimation accuracy to over 96%. The embedded prototype maintained an average inference speed of 10.5 FPS with a peak CPU temperature of 67.2°C during a continuous 2-hour stress test. These findings confirm that combining edge vision with turbidity-aware calibration substantially improves fingerling counting reliability in challenging aquatic environments of abandoned tin mining ponds.

Copyrights © 2026






Journal Info

Abbrev

JuLIET

Publisher

Subject

Control & Systems Engineering Electrical & Electronics Engineering Energy Engineering

Description

The Journal of Electricity, Instrumentation and Applied Electronics (JuLIET) is an open-access journal published by the Department of Electrical and Information Engineering, Vocational School, Gadjah Mada University. JuLIET is issued twice a year with varying volumes. JuLIET was first published, Vol ...