Jurnal Universal Technic
Vol. 5 No. 2 (2026): Jurnal Universal Technic

Efektivitas Perlindungan Cat Anti Fouling Terhadap Laju Korosi Baja A36 Terhadap Salinitas Air Laut

Ali Muktar Sitompul (Politeknik Ilmu Pelayaran Semarang)
Lilik Budiyanto (Universitas Maritim AMNI Semarang)
Devout Prakoso Trismianto (Universitas Maritim AMNI Semarang)
Briliannadia Briliannadia (Universitas PGRI Semarang)



Article Info

Publish Date
30 Oct 2026

Abstract

Corrosion attack on ships' hulls resulting from electrochemical reactions with highly saline seawater is a predominant cause of maritime transport accidents in Indonesia, including plate thinning, leakage, and sudden sinkings. This collaborative study evaluates the corrosion protection effectiveness of three protective coatings (Jotun, Primer, and Fluit/Flulit) applied on low-carbon ASTM A36 steel, the primary structural material for ships' hulls. The corrosion testing was carried out for six months (March - August 2025) using natural seawater collected from Tanjung Emas Port in Semarang at three distinct daily intervals (06:00, 12:00, and 18:00). Two exposure scenarios were simulated: daily refreshed seawater representing stable (dynamic) salinity, and unrefreshed stagnant seawater representing minimal circulation with unstable (concentrating) salinity. Quantitative corrosion rates were determined via the weight loss method in accordance with ASTM D 2688-05 using the Mils Per Year (MPY) metric. Under refreshed seawater conditions (stable salinity), all three paints displayed identical corrosion rates of 32 MPY (classified as moderate corrosion). Conversely, in unrefreshed stagnant seawater (unstable salinity), extreme performance divergence was observed: Jotun recorded outstanding protective barrier resilience with a corrosion rate of 0 MPY (classified as good protection), whereas both Primer and Fluit paints suffered catastrophic barrier breakdown, with corrosion rates skyrocketing to 439 MPY (classified as poor/failed protection). The electrochemical analysis confirms that concentrating chloride ions and unstable salinity in stagnant seawater trigger rapid polymer matrix degradation in non-marine coatings. Jotun demonstrated the most consistent and superior anti-corrosion efficiency across all environmental conditions. This study provides a scientific foundation for shipowners and crew to coordinate underwater hull maintenance schedules and optimize corrosion control budgets, especially within stagnant, low-circulation spaces such as ship void tanks

Copyrights © 2026