ENHANCEMENT OF THE SENSITIVITY AND SELECTIVITY OF THE VOLTAMMETRIC SENSOR FOR URIC ACID USING MOLECULARLY IMPRINTED POLYMER

Miratul Khasanah (Department of Chemistry, Airlangga University)
Mudasir Mudasir (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara, Kotak Pos 21 Bls Yogyakarta, Indonesia 55281)
Agus Kuncaka (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara, Kotak Pos 21 Bls Yogyakarta, Indonesia 55281)
Eko Sugiharto (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara, Kotak Pos 21 Bls Yogyakarta, Indonesia 55281)
Ganden Supriyanto (Department of Chemistry, Airlangga University)
Siti Wafiroh (Department of Chemistry, Airlangga University)



Article Info

Publish Date
14 Dec 2010

Abstract

The sensitivity and selectivity of voltammetric sensor for uric acid can be improved by modifying the working electrode using a polymer with a molecular template (molecularly imprinted polymer, MIP). Polymer and MIP was synthesized from methacrylic acid (MAA) as monomer, ethylene glycol dimethacrylic acid (EGDMA) as cross-linker, uric acid (UA) as template and the results were characterized by various methods. The poly-MAA formation was identified by a decrease in the intensity of infrared (IR) spectra at ~1540 cm-1 (C=C) and an increase at ~1700 cm-1 (C=O) compared to the IR spectra of the MAA and EGDMA. The SEM analysis showed that the cavity of polymer is small enough (~ 0.1 µm) and homogeneous. Establishment of MIP was carried out by extracting of the uric acid from the polymer network. The IR spectra of MIP exhibited the decrease in intensity at ~1700 cm-1 (C=O) compared to the non imprinted polymer (NIP). The data of BET analysis showed that polymer pore size increase slightly from 37.71 Å to 38.02 Å after the extraction process of uric acid from the polymer network. Its may be due to incomplete extraction of uric acid from the polymer network. Modifications of hanging mercury drop electrode using MIP made from MAA, EGDMA, and UA with a mole ratio of 1:3:1 produced a sensitive and selective voltammetric sensor for uric acid. The sensitivity obtained was 16.405 nA L/µg. The presence of ascorbic acid in equal concentration with uric acid decreased the current response of only 0.08%. Compared to HMDE electrode, the sensitivity and selectivity of the HMDE-MIP sensor enhanced about 100 and 700 times, respectively. The detection limit was found to be 5.94 x10-10 M.

Copyrights © 2010






Journal Info

Abbrev

ijc

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Chemistry

Description

Indonesian Journal of Chemistry is an International, peer-reviewed, open access journal that publishes original research articles, review articles, as well as short communication in all areas of chemistry including applied chemistry. The journal is accredited by The Ministry of Research, Technology ...