                            PROSES LISTRIK DALAM TUBUH MANUSIA 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 8 No 1 (2016): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (945.352 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
Bioelectromagnetism (sometimes equated with bioelectricity) refers to the electrical, magnetic or electromagnetic fields produced by living cells, tissues or organisms. Examples include the cell potential of cell membranes and the electric currents that flow in nerves and muscles, as a result of action potentials. It is not to be confused with bioelectromagnetics, which deals with the effect on life from external electromagnetism. Bioelectromagnetism involves the interaction of ions. Bioelectromagnetism is sometimes difficult to understand because of the differing types of bioelectricity, such as brainwaves, myoelectricity (e.g., heart-muscle phenomena), and other related subdivisions of the same general bioelectromagnetic phenomena. One such phenomenon is a brainwave, which neurophysiology studies, where bioelectromagnetic fluctuations of voltage between parts of the cerebral cortex are detectable with an electroencephalograph. This is primarily studied in the brain by way of electroencephalograms
                                
                             
                         
                     
                    
                                            
                        
                            OPTIMASI PRODUKSI ENERGI SURYA DARI DESAIN PEMBANGKIT TENAGA SURYA DI ATAP STT-PLN 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 8 No 1 (2016): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (1031.279 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
In the future, the greater of the consumption energy, the use of diverse energy sources can not be avoided. Therefore, assessment of the various sources of energy technologies continue to be developed. Photovoltaic technologies that convert solar energy directly into electrical energy using semiconductor devices called solar cells. Solar energy apart easily obtained from natural, environmentally friendly too which does not produce CO2 emissions to become a mainstay in the world of technology. The problem is how to use solar panels to get optimal production of electrical energy as solar panels are generally placed at a certain position without change.The design of this solar cells, built at roof over an area of 50 m2 has a power output of 6 kWp with the installation of solar panels with a slope of 6 degrees which can produce electrical energy about 10,006.7 kWh per year. It is connected to the grid (grid connected) without battery. For the manufacture of solar investment of Rp. 445.453.328, - where the investment already include the cost of maintenance and life cycle costs over 25 years.
                                
                             
                         
                     
                    
                                            
                        
                            MENGATASI RUGI-RUGI EKSTERNAL DALAM PERENCANAAN TRANSMISI KABEL BAWAH LAUT 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 8 No 1 (2016): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (1024.583 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
To go to JDPT, improving the capability and reliability of the systems associated therewith, both switching system or transmission media becomes very important. One of the transmission medium that supports JDPT is a submarine cable which is better known fiber cable optick. Fiber optic cable is suitable for transmission of digital and analog, has a damping small and wide bandwidth, flexible to increase channel capacity and have a diameter or size is small and the way the installation is also not much different from the usual multipair cable. The use of fiber optics is increasingly widespread, so some efforts to reduce losses arising from the installation of fiber optic cables is still being done to improve the quality of fiber optic transmission.
                                
                             
                         
                     
                    
                                            
                        
                            ANALISA DCS (DISTRIBUTED CONTROL SYSTEM) PADA PROSES POLIMERISASI 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 8 No 1 (2016): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (1047.822 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
With the development of technology in the industrial market today , many factories - factories require DCS (Distributed Control System) to control the process equipment at the plant. DCS function to read the response is rapid in plant equipment has been fitted with sensors . In this paper will be analyzed the use of DCS in the polymerization process at the factory PT Indorama Synthetics are located in Jatiluhur - Purwakarta , West Java . At PT Indorama Synthetics polymerization process using CENTUM DCS 3000 that can control and monitor every machine connected to the DCS . With the use of DCS , factory PT . Indorama Synthetics can mengontol flow from the tank PTA and EG tank that produces an output flow of 10423 kg / h.
                                
                             
                         
                     
                    
                                            
                        
                            GANGGUAN PADA GARDU DISTRIBUSI TIPE PORTAL 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 8 No 1 (2016): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (1082.259 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
Means the latest in low voltage distribution systems for the provision of electric power supply before it gets to the customer, which generally are household customers. For medium voltage electric power system, the direct distribution system by using medium voltage 20 kV to substations - distribution substations then poured into PHB - TR and through the low voltage network forwarded kepelanggan. Medium voltage networks frequent disruptions. The cause - the cause disturbances in the portal substations and low voltage distribution systems. This research will discuss the disorder - disruption in the distribution on the type of portal. With a determines a disturbance more quickly, it can minimize the occurrence of a power outage.
                                
                             
                         
                     
                    
                                            
                        
                            RANCANGAN SISTEM KEAMANAN LOKER PADA ALAT PENGISI BATERAI GADGET UNTUK FASILITAS UMUM:E-LOCKER 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 8 No 1 (2016): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (793.872 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
In this research, RFID is used as an electronic key opener safety deposit box (locker) which exist in the location (public areas) , such as equipment filler battery on electronic devices gadgets using solar energy , thus the resources of electronic lock uses battery filled through solar. System electronic lock solenoid doorlock working with RFID tag and RFID reader with Arduino UNO. From the test results, the RFID tag can recognize RFID reader with a reading at a distance of 6 cm. The results of this study applied to the locker battery gadget charger with solar energy.
                                
                             
                         
                     
                    
                                            
                        
                            KINERJA RELAY JARAK DI TRANSMISI BERDASARKAN PENGARUH STATCOM 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 8 No 1 (2016): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (987.594 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
By using equipment FACTS (flexible AC transmission systems) on the transmission line is an attempt to make the Electric Power System more efficient and reliable is one compensation equipment in FACTS is STATCOM or static synchronous compensator. Controlling the voltage stability on the transmission line can use Static synchronous compensator, so as ultimately increase the power transfer capability on the channel. Voltage and current signals in the relay will be affected by the STATCOM on the transmission line. This influence would have no effect on the performance of the protection system, such as the distance relay. This research will discuss about the transmission line is compensated by STATCOM based on the performance of the distance relay.
                                
                             
                         
                     
                    
                                            
                        
                            ANALISA KUAT HANTAR ARUS KABEL TANAH 150 kV YANG MELINTASI JEMBATAN 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 7 No 2 (2015): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (443.405 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
The use of underground cables in transmission lines and the distribution of today is increasing rapidly, especially in urban and industrial areas. Electrical power supply between 150 kV substation using a cable. When cables pass through unfavorable as paved areas and bridges, then decrease the heat transfer from the cable to the environment. The heat will accumulate resulting in temperature rise, so capability of ground wire current-carrying wires must be lowered so that the ground is not damaged due to limited working temperature insulating materials. This research will discuss the current-carrying strength analysis of 150 kV land cables that cross the bridge.
                                
                             
                         
                     
                    
                                            
                        
                            ANALISIS PENGARUH JENIS BEBAN LISTRIK TERHADAP KINERJA PEMUTUS DAYA LISTRIK DI GEDUNG CYBER JAKARTA 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 7 No 2 (2015): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (1124.173 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
The development of the electricity system can not be separated from the development of the distribution system and in the development of the electric power distribution system there are some things that needs to be considered, one of which is characteristic of the load on the power distribution network. Because of the nature / characteristics of the electrical load can cause interference in the distribution system. Disorders that arise as a result of the load, these include the emergence of harmonic waves on power distribution systems.From the results of measurements that have been done on the electrical power circuit breaker (MCCB) of the fifth house obtained measured total harmonic current distortion ranged 5.8% ≤ ITHD ≤ 51%, while the calculation results ranged from 7.54% ≤ ITHD ≤ 66.1%. This data shows the fundamental current waveform distortion that exceeds the standard IEEE and IEC is 15%. The presence of current distortion harmonic waves that exceed the allowable limits on electric power distribution system will cause a disruption in the power distribution system, one of which is at the breaker electrical power trip (OFF), because of the resonance frequency caused by distortion of the current wave fundamental. Besides being able to interference with the performance of electrical power breaker, the wave harmonic distortion can cause a rise in the current and voltage on the neutral wire.
                                
                             
                         
                     
                    
                                            
                        
                            ASUT LANGSUNG DAN PEMBEBANAN VARIABLE MOTOR INDUKSI 
                        
                        Redaksi Tim Jurnal                        
                         Energi & Kelistrikan Vol 7 No 2 (2015): Energi & Kelistrikan 
                        
                        Publisher : Sekolah Tinggi Teknik PLN 
                        
                             Show Abstract
                            | 
                                 Download Original
                            
                            | 
                                
                                    Original Source
                                
                            
                            | 
                                
                                    Check in Google Scholar
                                
                            
                                                            |
                                
                                
                                    Full PDF (492.653 KB)
                                
                                                                                
                        
                            
                                
                                
                                    
There are still many books or papers in the Indonesian language explaining that big induction motors are not allowed with DOL (direct on line) starting. This paper will explain how DOL starting of big induction motors is possible. This paper also explain details about variable load of big induction motors.