cover
Contact Name
surya
Contact Email
energisurya.teump@gmail.com
Phone
-
Journal Mail Official
energisurya.teump@gmail.com
Editorial Address
-
Location
Kota palembang,
Sumatera selatan
INDONESIA
JURNAL SURYA ENERGY
ISSN : 25287400     EISSN : 2615871X     DOI : -
Core Subject : Engineering,
Jurnal Surya Energy (JSE) Electrical Engineering, Faculty of Engineering, Muhammadiyah University Palembang is a journal that contains scientific research results in the field of Electrical Engineering. JSE is for lecturers, students, researchers, and practitioners who concentrate and contribute in the field of Electrical Engineering, which have never been published in other journals. published twice in March and September.
Arjuna Subject : -
Articles 5 Documents
Search results for , issue "Vol. 2 No. 1 2017" : 5 Documents clear
STUDI SKEMA PELEPASAN BEBAN SECARA OTOMATIS PADA SAAT SISTEM 70 kV KEHILANGAN SUPLAI DARI SISTEM 150 kV DI KERAMASAN MENGGUNAKAN RELE (UFR) Sofiah, Sofiah; Nopiansyah, Airi
JURNAL SURYA ENERGY Vol. 2 No. 1 2017
Publisher : UNIVERSITAS MUHAMMADIYAH PALEMBANG

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32502/jse.v2i1.776

Abstract

Penelitian ini membahas tentang skema pelepasan beban secara otomatis mengunakan rele, Under Frekuensi Rele (UFR) pada sistem 70 kV Keramasan. Pelepasan beban dilakukan sebagai suatu usaha memperbaiki kesetabilan sistem yang terganggu karena beban lebih akibat terjadi gangguan pada sistem penyaluran, nilai frekuensi dapat melewati batas tinggi (52 Hz) ataupun dibawah dari batas rendah (47.5 Hz). Pelepasan beban diharapakan dapat memulihkan frekuensi dengan cepat dan jumlah beban yang dilepas seminimal mungkin. Oleh sebab itu diperlukan beberapa tahapan pelepasan beban untuk mendapatkan nilai frekuensi yang maksimal.Pelepasan beban dengan rele frekuensi kurang harus dapat mengakomodir berbagai kategori beban tenaga listrik, mulai dari hari kerja, hari libur, maupun hari libur nasional (hari khusus). Selain itu, penerapan skema ini harus dapat mengembalikan nilai frekuensi pada rentang yang masih memungkinkan pembangkit dapat beroperasi secara normal sesuai standar pada Aturan Jaringan PLN ( 49,7 Hz < f < 50,2 Hz ).
PERANCANGAN SISTEM MONITORING KEAMANAN JARINGAN JARAK JAUH MENGGUNAKAN MIKROTIK OPERATIONAL SYSTEM MELALUI VIRTUAL PRIVATE NETWORK Ardianto, Feby; Akbar, Tri
JURNAL SURYA ENERGY Vol. 2 No. 1 2017
Publisher : UNIVERSITAS MUHAMMADIYAH PALEMBANG

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32502/jse.v2i1.777

Abstract

Mikrotik Routerboard merupakan suatu sistem operasi jaringan yang difungsikan sebagai router untuk membuat jaringan semakin handal.Penggunaan jaringan internet sangat berkembang pesat, sehingga pemanfaatan dalam penggunaan jaringan internet sangat mudah untuk disalah gunakan. Mikrotik sebagai router jaringan menjadi solusi untuk mengontrol penggunaan jaringan yang sesuai aturan dan tidak disalah gunakan. Seiring dengan semakin tingginya kebutuhan dan semakin banyaknya penggunaan jaringan yang menginginkan suatu bentuk jaringan yang dapat memberikan hasil maksimal baik dari segi efisiensi maupun peningkatan keamanan jaringan itu sendiri. Kegiatan monitoring jaringan merupakan kegiatan yang dilakukan untuk mengelola suatu sistem jaringan dilokasi atau area tertentu. Sistim monitoring ini dipergunakan untuk mempermudah tim teknik dalam melakukan pemantauan secara rutin kondisi jaringan di lapangan.
PENGGUNAAN GYPSUM DAN MAGNESIUM SULFAT SEBAGAI UPAYA MENURUNKAN NILAI RESISTANSI PENTANAHAN Yuniarti, Erliza; Hermanto, Dedy; Ahmad, Prima
JURNAL SURYA ENERGY Vol. 2 No. 1 2017
Publisher : UNIVERSITAS MUHAMMADIYAH PALEMBANG

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32502/jse.v2i1.778

Abstract

Sistem pentanahan atau pembumian sangat dibutuhkan untuk pengamanan sistem tenaga listirk dan penangkal petir, dengan cara mengalirkan arus gangguan ke tanah. Semakin kecil nilai resistansi atau tahanan pentanahan akan semakin baik terutama untuk pengamanan personil dan peralatan-peralatan listrik. Perlakuan terhadap elektroda pentanahan jenis rod berbahan tembaga menggunakan gypsum (CaS4.2HO) yang dapat menyerap air dan magnesium sulfat (MgSO42) yang dapat menetralisir kejenuhan elektroda dan dapat menurunkan tingkat keasaman tanah sehingga membantu proses perlambatan korosi yang terjadi pada elektroda. Perlakuan untuk menurunkan nilai resistansi dengan penambahan gypsum dan mangnesium sulfat menggunakan bantuan kotak berbahan aluminium, didapat nilai resistansi pentanahan sebesar 1Ω, menjadi upaya yang paling efektif u
ANALISA KEANDALAN PENYULANG 20 KV DI JAKABARING SPORT CITY (JSC) DALAM MENGHADAPI ASIAN GAMES KE XVIII TAHUN 2018 Putra, Dian Eka; Nurdiana, Nita; Simatupang, Roli
JURNAL SURYA ENERGY Vol. 2 No. 1 2017
Publisher : UNIVERSITAS MUHAMMADIYAH PALEMBANG

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32502/jse.v2i1.794

Abstract

The reliability of the 20 kV voltage distribution is a topic that has received widespread attention from the entire community including technicians, engineers, customers and others. This is because distribution reliability performance directly affects customers (consumers). In facing the implementation of the ASEAN GAMES to XVIII in Jakabaring Sport City (JSC) the provision of electrical energy required a good distribution system. The fundamental problems in the distribution of electrical power are on the quality, continuity and availability of electric power services to customers. The continuity of the supply of electrical energy to a buffer is greatly influenced by the reliability of the distribution system. Reliability describes a measure of the level of electricity supply service of the system greatly influenced by the configuration of the system, the installed security device and its protection system. To determine the reliability of a repeater in sports complex Jakabaring Sport City to meng ASEAN ASEAN GAMES to XVIII then set a reliability index that is the amount to compare the appearance of a distribution system. The reliability index is an indicator expressed in the probability scale. Index Reliability The commonly used load points include average load-out rate, average out time and average load-term duration. The widely used system reliability indexes include System Average Interruption duration Index (SAIDI) obtained by 0.00037802 min / mop and System Average Interruption Frequency Index (SAIFI) obtained value 0.00081712 times / mole and limited energy capacity hence required a standard where the efficiency of electricity can be taken into account.
OPTIMASI TEMPERATUR DAN ARUS UNTUK MENGHASILKAN TEGANGAN 12 VOLT DC PADA THERMOELECTRIC GENERATOR MODEL SP 1848-27145 SEBAGAI ACCUMULATOR CHARGER Cekdin, Cekmas; Rahmayani, Siska
JURNAL SURYA ENERGY Vol. 2 No. 1 2017
Publisher : UNIVERSITAS MUHAMMADIYAH PALEMBANG

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32502/jse.v2i1.775

Abstract

One source of potential energy with new innovations, namely the use of thermoelectric generator. Utilization of thermoelectric generators as a Heat power plant requires further study or research to produce an optimal system so that it can be a source of electrical energy substitutes in the provision of electrical energy. The working principle of the heat power plant is the first thermoelectric generator heated by filament where between filament and thermoelectric generator coated sheet metal. If the temperature of the heated metal is greater than the temperature of the metal heat dissipation, so experienced certain temperature difference difference, then the temperature difference causes a thermoelectric generator starts to work optimally. Measurement of Thermoelectric Generator with model number SP 1848-27145 carried out a total of 11 experiments on different materials with the same method. It consists of 4 modules compiled series, saddled lamp dc 12 Volt, 5 Watt. Optimization for charging the accumulator is 12 volts dc with temperature 270C and with a current that is obtained is 3.01 Ampere.

Page 1 of 1 | Total Record : 5