cover
Contact Name
Yulia Nadar Indrasari
Contact Email
admin@indonesianjournalofclinicalpathology.org
Phone
+6285733220600
Journal Mail Official
majalah.jicp@yahoo.com
Editorial Address
Laboratorium Patologi Klinik RSUD Dr. Soetomo Jl. Mayjend. Prof. Dr. Moestopo 6-8 Surabaya
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Indonesian Journal of Clinical Pathology and Medical Laboratory (IJCPML)
ISSN : 08544263     EISSN : 24774685     DOI : https://dx.doi.org/10.24293
Core Subject : Health, Science,
Indonesian Journal of Clinical Pathology and Medical Laboratory (IJCPML) is a journal published by “Association of Clinical Pathologist” professional association. This journal displays articles in the Clinical Pathology and Medical Laboratory scope. Clinical Pathology has a couple of subdivisions, namely: Clinical Chemistry, Hematology, Immunology and Serology, Microbiology and Infectious Disease, Hepatology, Cardiovascular, Endocrinology, Blood Transfusion, Nephrology, and Molecular Biology. Scientific articles of these topics, mainly emphasize on the laboratory examinations, pathophysiology, and pathogenesis in a disease.
Articles 1,373 Documents
The Value of Cardiac Troponin I and Midkine in Predicting Coronary Artery Obstruction Severity in Chronic Coronary Syndromes (CCS) Moayed Basheer Hamid; Amal Abbas Hammoodi; Basil Oied Mohemed Salih; Ameen Al-Alwany
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY Vol. 32 No. 3 (2026)
Publisher : Indonesian Association of Clinical Pathologist and Medical laboratory

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24293/ijcpml.v32i3.2709

Abstract

High-sensitive cardiac troponin I (hs-cTnI) is a recognized marker of myocardial injury in acute coronary syndromes, but its utility in chronic coronary syndromes (CCS) remains unclear. Midkine (MK), a heparin-binding growth factor, plays a role in inflammation and vascular remodeling in atherosclerosis. This cross-sectional study aimed to evaluate the predictive value of serum hs-cTnI and MK in determining the severity of coronary artery obstruction in patients with CCS. The study included 125 subjects undergoing coronary angiography (CAG) at the Iraqi Center of Heart Disease/ Medical City/Baghdad, from March to December 2024. Subjects were classified into three groups based on CAG findings: no CAD, 1- or 2-vessel disease, and 3-vessel or left main disease. Serum levels of hs-cTnI and MK were measured using enzyme-linked immunosorbent assay (ELISA) in the laboratories of Department of Biochemistry/College of Medicine/ Baghdad University. Median serum levels of both biomarkers differed significantly across all groups. Receiver operating characteristic curve analysis demonstrated good diagnostic performance for both biomarkers in differentiating moderate (Group II) from severe disease (Group III). For hs-cTnI, a cutoff of 354.4 pg/mL yielded 90% sensitivity and 92% specificity; for MK, a cutoff of 2.75 ng/mL yielded 90% sensitivity and 85% specificity. Logistic regression revealed that the two biomarkers together explained 75% of the variance in CAD severity. Combining the two markers offered a slight improvement in diagnostic accuracy compared to using either alone. In conclusion, serum hs-cTnI and MK levels may help predict CAD severity in CCS and support early risk stratification before CAG.
Evaluation of Platelet Count Techniques in EDTA-Induced Pseudothrombocytopenia: Sysmex XN and Mindray BC Series Saristha Buathong; Natchanon Thongrud; Kanta Durmsung; Peempol Chokchaipermpoonphol
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY Vol. 32 No. 3 (2026)
Publisher : Indonesian Association of Clinical Pathologist and Medical laboratory

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24293/ijcpml.v32i3.2721

Abstract

Ethylenediaminetetraacetic acid-induced pseudothrombocytopenia (EDTA-PTCP) causes falsely low platelet counts due to in vitro platelet aggregation, risking misdiagnosis. Conventional methods may be unreliable in such cases. Advanced technologies, including PLT-O (optical fluorescence-based counting) in the Sysmex XN10 and Mindray BC6200, and PLT-H (hybrid method combining optical and impedance techniques) in the Mindray BC760, aim to enhance counting accuracy. This study aimed to evaluate the performance of these techniques in both untreated and kanamycin-treated EDTA-PTCP samples. Sixty-five EDTA-PTCP samples were analyzed using Sysmex XN10, Mindray BC6200, and Mindray BC760 analyzers before and after kanamycin treatment. Manual platelet counts served as the reference standard. Statistical analysis included paired t-tests and correlation coefficients to compare analyzer performance. Platelet flagging sensitivity was assessed to evaluate the analyzers’ ability to detect abnormalities. All three analyzers demonstrated improved accuracy following kanamycin treatment, with post-treatment correlations (R-values) exceeding 0.82. The Mindray BC6200 PLT-O method showed the highest correlation both before (R = 0.774) and after treatment (R = 0.910), with minimal bias (slope = 0.982; intercept = –8.945), and outperformed Sysmex in both correlation and agreement. In terms of platelet clumping detection, the combined flagging sensitivity was highest for Mindray BC6200 and BC760 (0.800), compared to Sysmex XN10 (0.338). These findings support the use of kanamycin and advanced optical methods for improving diagnostic reliability in EDTA-PTCP cases.
Model of a Field Hospital Laboratory System in Military Operations and Disaster Response Cecilia F. Harsono; Marsetio; Anton Nugroho; I Nengah Putra Apriyanto; Bambang Kustiawan; Faonaso Harefa
INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY Vol. 32 No. 3 (2026)
Publisher : Indonesian Association of Clinical Pathologist and Medical laboratory

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24293/ijcpml.v32i3.2858

Abstract

This study aimed to establish a field hospital laboratory system model that is adaptive, rapid, and compliant with standards of clinical pathology within the context of military operations and disaster response. A descriptive qualitative approach was employed to analyze the effectiveness of portable laboratory services. The findings demonstrated that hematology, clinical chemistry, and rapid microbiology examinations can be conducted within relatively short timeframes with reliable outcomes, achieving an agreement rate of more than 85% compared to reference laboratories, despite the limited capacity for sample processing. The primary challenges identified include logistical constraints, infrastructural instability, and the necessity of civilian–military integration in laboratory management. These findings culminated in the formulation of a field hospital laboratory system model emphasizing the efficiency of portable examinations, resilience of supply chains, application of adaptive biosafety practices, and cross-sectoral coordination. It is concluded that field hospital laboratories play a strategic role in accelerating diagnosis and therapy while simultaneously strengthening health resilience and national defense. Recommendations include the development of validated point-of-care testing devices, reinforcement of logistics and infrastructure, formalization of civilian–military integration through regulatory frameworks, enhancement of medical personnel training, and further research across diverse operational and disaster scenarios.

Filter by Year

2005 2026


Filter By Issues
All Issue Vol. 32 No. 3 (2026) Vol. 32 No. 2 (2026) Vol. 32 No. 1 (2025) Vol. 31 No. 3 (2025) Vol. 31 No. 2 (2025) Vol. 31 No. 1 (2024) Vol. 30 No. 3 (2024) Vol. 30 No. 2 (2024) Vol. 30 No. 1 (2023) Vol. 29 No. 3 (2023) Vol. 29 No. 2 (2023) Vol. 29 No. 1 (2022) Vol 29, No 1 (2022) Vol. 28 No. 3 (2022) Vol 28, No 3 (2022) Vol. 28 No. 2 (2022) Vol 28, No 2 (2022) Vol. 28 No. 1 (2021) Vol 28, No 1 (2021) Vol 27, No 3 (2021) Vol. 27 No. 3 (2021) Vol. 27 No. 2 (2021) Vol 27, No 2 (2021) Vol. 27 No. 1 (2020) Vol 27, No 1 (2020) Vol. 26 No. 3 (2020) Vol 26, No 3 (2020) Vol 26, No 2 (2020) Vol. 26 No. 2 (2020) Vol 26, No 1 (2019) Vol. 26 No. 1 (2019) Vol. 25 No. 3 (2019) Vol 25, No 3 (2019) Vol. 25 No. 2 (2019) Vol 25, No 2 (2019) Vol 25, No 1 (2018) Vol. 25 No. 1 (2018) Vol. 24 No. 3 (2018) Vol 24, No 3 (2018) Vol. 24 No. 2 (2018) Vol 24, No 2 (2018) Vol. 24 No. 1 (2017) Vol 24, No 1 (2017) Vol 23, No 3 (2017) Vol. 23 No. 3 (2017) Vol 23, No 2 (2017) Vol. 23 No. 2 (2017) Vol 23, No 1 (2016) Vol 22, No 3 (2016) Vol 22, No 2 (2016) Vol 22, No 1 (2015) Vol 21, No 3 (2015) Vol 21, No 2 (2015) Vol 21, No 1 (2014) Vol 20, No 3 (2014) Vol 20, No 2 (2014) Vol 20, No 1 (2013) Vol 19, No 3 (2013) Vol 19, No 2 (2013) Vol. 19 No. 1 (2012) Vol 19, No 1 (2012) Vol 18, No 3 (2012) Vol. 18 No. 3 (2012) Vol 18, No 2 (2012) Vol 18, No 1 (2011) Vol. 18 No. 1 (2011) Vol 17, No 3 (2011) Vol 17, No 2 (2011) Vol 17, No 1 (2010) Vol 16, No 3 (2010) Vol 16, No 2 (2010) Vol 16, No 1 (2009) Vol 15, No 3 (2009) Vol 15, No 2 (2009) Vol 15, No 1 (2008) Vol 14, No 3 (2008) Vol 14, No 2 (2008) Vol 14, No 1 (2007) Vol 13, No 3 (2007) Vol 13, No 2 (2007) Vol 13, No 1 (2006) Vol 12, No 3 (2006) Vol 12, No 2 (2005) Vol 12, No 1 (2005) More Issue