Indonesian Journal of electronics, electromedical engineering, and medical informatics
ISSN : -     EISSN : 26568624     DOI : https://doi.org/10.35882/ijeeemi
The Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics (IJEEEMI) is a peer-reviewed open-access journal. The journal invites scientists and engineers throughout the world to exchange and disseminate theoretical and practice-oriented topics which covers three (3) majors areas of research that includes 1) Electronics, 2) Biomedical Engineering, and 3) Medical Informatics (emphasize on intelegent system design). Submitted papers must be written in English for an initial review stage by editors and further review process by a minimum of two reviewers.
Articles 6 Documents
Search results for , issue "Vol 3 No 3 (2021): August" : 6 Documents clear
Vital Sign Monitor Device Equipped with a Telegram Notifications Based on Internet of Thing Platform Sari Luthfiyah; Agatha Putri Juniar Putri Juniar Santoso; Tri Bowo Indrato; Michelle Omoogun
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.4

Abstract

Vital Sign Monitor is a tool used to diagnose a patient who needs intensive care to know the condition of the patient. Parameters used in monitoring the patient's condition include body temperature and respiration. The contribution of this research designed a vital sign monitoring tool with IoT-based notifications so that remote monitoring can be done by utilizing web Thinger.io, LCD, RGB LEDs as a display of the results of the study and notify telegrams if it becomes abnormal to the patient's condition. Therefore, in order to produce accurate data in the process of data retrieval, a relaxed position of the patient is required and the stability of the wi-fi network so that monitoring is not hampered. The study used the DS18B20 digital temperature sensor placed on the axilla and the piezoelectric sensor placed on the abdomen of the patient. The results of the study were obtained by taking data on patients. The resulting temperature value will be compared to the thermometer, which produces the highest error value of 0.56%, which is still possible because the tolerance limit is 1oC. and for the collection of respiration values that have been compared to the patient monitor obtained the highest error value of 6.2%, which is still feasible because the tolerance limit is 10%. In this study, there is often a crash library between the temperature sensor and other sensors, so for further research, recommend to replacing the temperature sensor
Design a Monitoring Device for Heart-Attack Early Detection Based on Respiration Rate and Body Temperature Parameters Isna Fatimatuz Zahra; I Dewa Gede Hari Wisana; Priyambada Cahya Nugraha; Hayder J Hassaballah
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.5

Abstract

Acute myocardial infarction, commonly referred to as a heart attack, is the most common cause of sudden death where a monitoring tool is needed that is equipped with a system that can notify doctors to take immediate action. The purpose of this study was to design a heart attack detection device through indicators of vital human signs. The contribution of this research is that the system works in real-time, has more parameters, uses wireless, and is equipped with a system to detect indications of a heart attack. In order for wireless monitoring to be carried out in real-time and supported by a detection system, this design uses a radio frequency module as data transmission and uses a warning system that is used for detection. Respiration rate was measured using the piezoelectric sensor, and body temperature was measured using the DS18B20 temperature sensor. Processing of sensor data is done with ESP32, which is displayed wirelessly by the HC-12 module on the PC. If an indication of a heart attack is detected in the parameter value, the tool will activate a notification on the PC. In every indication of a heart attack, it was found that this design can provide notification properly. The results showed that the largest respiratory error value was 4%, and the largest body temperature error value was 0.55%. The results of this study can be implemented in patients who have been diagnosed with heart attack disease so that it can facilitate monitoring the patient's condition.
Effect of Closed and Opened the Door to Temperature on PID-Based Baby Incubator with Kangaroo Mode Vanda Catur Kirana; Dwi Herry Andayani; Andjar Pudji
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.6

Abstract

The uneven distribution of the baby incubator temperature can cause the temperature in the baby incubator to be different at each point. The purpose of this study was to analyze the effect of the door closed and opened to the temperature at each point of sensor placement that has been determined. The study was conducted as an experimental research design. In this experiment, an Incu Analyzer comparison was used as a calibrator unit, a baby skin temperature thermistor sensor, and four LM35 sensors for baby incubator room temperature with one LM35 sensor as a PID control system carried out by trial-and-error method. Based on the results of measurements was made with the design, when the chamber is open, it produces an average error value of T1 4.083%, T2 6.06%, T3 3.78%, T4 4.88%, and T5 1.48%, while when the chamber is closed, it produces an average error value T1 0.75. %, T2 0.88%, T3 1.15%, T4 0.74%, and T5 0.87%. Measurement of skin temperature using a thermometer has an average error value of 1.1%. The results showed that uneven heat transfer, lack of air distribution, different sensor placements at each point, and non-standard chamber sizes were factors that were uneven at each point. Based on the results of the study, it was found that the use of a working system on this device can be implemented to control the temperature of the baby incubator by knowing the temperature distribution at each point
Modeling, Simulation, and Stabilization of a Two-Wheeled Inverted Pendulum Robot Using Hybrid Fuzzy Control Made Rahmawaty
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.2

Abstract

Two wheels inverted pendulum robot has the same characteristics as an inverted pendulum, which are unstable and nonlinear. Nonlinear systems can often be linearized by approximating them by a linear system obtained by expanding the nonlinear solution in a series, and then linear techniques can be used. Fuzzy logic control is the famous nonlinear controller that researchers have used to analyze the performance of a system due to the easiness of understanding the nature of the controller. This research discusses two wheels inverted pendulum robot design using hybrid fuzzy control. There are two types of fuzzy control: Fuzzy Balanced Standing Control (FBSC) to maintain stability and Fuzzy Traveling and Position Control (FTPC). Based on Takagi-Sugeno (T-S) fuzzy model on two wheels inverted pendulum robot, FBSC control used Parallel Distributed Compensation (PDC) with pole placement technic. Based on two wheels inverted pendulum robot movement characteristics, FTPC was designed using Mamdani Fuzzy architecture. FTPC control is used to help FBSC maintain robot stability and adjust to the desired position. The simulation result shows that the controller for two wheels inverted pendulum robot can stabilize pendulum angle in 0 radian and close to the desired position.
Automatic Measurement of Neutral Foot Posture Using Three-Dimensional Scanning Chien-Hung Lin; Yan-Yu Lin
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.1

Abstract

The Rearfoot Angle (RFA) is the most common method used for foot posture assessment, and it is also a method for evaluating the subtalar joint neutral foot posture. However, orthopedists and researchers often meet trouble for the measurements of the RFA and neutral foot posture due to lacking measurement with automation and objectivity. In general, the RFA was measured using a goniometer to align with manual markers on foot. The purpose of this study implements the automatic computing of leg angle, foot angle, and RFA by the foot model using Three-Dimensional (3D) scanning. This study aims to implement the automatic and objective computing of leg angle, foot angle, and RFA by the foot model using 3D scanning. The automatic calculation on leg angle, foot angle, and neutral foot posture has been created, tested, and validated completely in this study. Two algorithm methods are proposed to determine the midpoint on the leg or foot outline. The midline has been computed by linear regression through five midpoints. The leg and foot angles are calculated by the tibial and calcaneal midlines, respectively. Through the subject standing on eversion foot platforms, the neutral posture of the foot can be computed by the leg and foot angles determined by the 3D model scanned of the foot with various tilt angles. The determinations of the midpoint and midline have been demonstrated algorithm by MATLAB. Based on comparing with the goniometer measured, selecting the midpoint algorithm of the limit points and the lowest point methods to determine the tibial and calcaneal midlines would produce better results. The foot 3D scanning measurement proposed in this study has been tested and validated from the goniometer. This study can determine the leg angle, foot angle, and neutral foot postures for a subject with normal weight status but not suitable for obese weight status. This study can provide guidance for foot posture assessment and personal insoles design in the future.
A Simple Medical Record System of Non-Invasive Blood Glucose Level Measurement Results for Diabetes Care Using Graphical User Interface (GUI) MATLAB Nur Hasanah Ahniar
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): August
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i3.3

Abstract

We present a medical records system and reminders to patients of the measurement results of non-invasive blood glucose levels. Measuring blood glucose levels is vital in avoiding potential adverse health effects like diabetes. Diabetes is a chronic metabolic disorder caused by a decrease in the pancreas to produce insulin. Generally, measuring blood glucose levels using the conventional method is injure the patient's finger. Currently, the non-invasive method was famous as one of the detections of blood glucose by applying the physical properties of laser absorption. In this paper, we use the photodiode as a detector, the LED as a sensor, and a signal conditioning circuit. The results showed that non-invasive glucose monitoring has the potential to measure glucose levels with sensitivity and linearity of 3.21 mg/dL and 98%, respectively. As a result of measuring the blood glucose levels of the subject was displayed on the LCD module was designed. We designed a simple application and medical record using Blynk applications and GUI MATLAB for recording the measurement results of blood glucose level. In the future, applications that have been developed can be used by doctors for monitoring the measurement of the blood glucose level and provide information to patients by mobile applications, sending an email or message the measurement results, the decision of a disease or not, and reminds the re-measurement time.