ISSN : 23390905     EISSN : 26553643     DOI : -
Integrated Lab Journal published by Sunan Kalijaga State Islamic University of Yogyakarta as a media for scientific paper about educational laboratories. The focus and scope of journal is about : 1. Educational Laboratories Tools, Equipment, or Machine : Maintenace and safety Procedures and instalation Engineering and design Instrumentation and control Mechanism and construction 2. Material, Stuff, Ingredient, Component, Spare parts for educational laboratories : Storage and inventories Data and specification Purification Compound Mixture 3. Methods for educational Laboratories
Arjuna Subject : Umum - Umum
Articles 5 Documents
Search results for , issue "Vol. 8 No. 1 (2020)" : 5 Documents clear
Validasi Metoda Destruksi Basah dan Destruksi Kering pada Penentuan Logam Timbal (Pb) dan Kadmium (Cd) Dalam Tanaman Rumput Yusuf Habibi
Integrated Lab Journal Vol. 8 No. 1 (2020)
Publisher : UIN Sunan Kalijaga Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14421/ilj.2020.080103

Abstract

Telah dilakukan penelitian validasi metoda destruksi kering dan basah pada penentuan logam kadmium (Cd) dan timbal (Pb) dengan alat Spektrofotometer Serapan Atom. Validasi metoda didasarkan pada jaminan mutu sesuai SNI. Hasil validasi metoda menunjukkan bahwa metoda destruksi kering lebih valid dibanding metoda destruksi basah. Validitas ditunjukkan dengan nilai kadar logam yang optimal, nilai korelasi standar di atas 0,995, % RPD dibawah 10%, dan % R dalam rentang 85% - 115 %.
Pengaruh Penggunaan Natrium Hipoklorit (NaOCl) Dalam Cairan Pemutih Pakaian Sebagai Pereaksi Pengujian Amonia Pada Air Limbah Ida Ayu Sulistya
Integrated Lab Journal Vol. 8 No. 1 (2020)
Publisher : UIN Sunan Kalijaga Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14421/ilj.2020.080104

Abstract

Pengujian amonia dalam air limbah menggunakan NaOCl sebagai salah satu pereaksinya. Untuk kebutuhan pengujian kimia digunakan NaOCl dengan kualitas pro-analysis memiliki harga ekonomis lebih tinggi dibanding dengan bahan kualitas teknis. Sifat dari NaOCl sangat mudah berubah atau mengalami kerusakan sehingga selama ini menyebabkan NaOCl yang ada di laboratorium sering dilimbahkan sebelum waktu kedaluarsanya. Untuk mengurangi pembuangan bahan pereaksi yang masih tersedia dalam jumlah banyak dilakukan penggunaan bahan pereaksi alternatif, yaitu NaOCl yang terdapat pada cairan pemutih. Pemutih pakaian sebagai reagen dapat digunakan jika hasil pengujiananya tidak berbeda signifikan dengan hasil uji yang menggunakan reagen NaOCl p.a. Perbandingan kedua jenis reagen tersbut dilakukan pada penelitian ini, selanjutnya hasil diuji secara statistic dengan metode Uji T Two Sample Test. Hipotesis pada uji t ini adalah H0 = hasil uji kedua reagen sama dan H1 = hasil uji kedua reagen berbeda secara nyata. Hasil t hitung yang diperoleh pada uji t ini adalah 1,874. Sementara nilai t tabel dari kepercayaan 95% (probabilitas 0,05) dengan derajat bebas 12 adalah 2,179. Nilai dari t hitung lebih kecil dari t tabel maka H0 diterima. Artinya penggunaan reagen A (NaOCl) memiliki hasil yang sama atau tidak berbeda nyata dengan hasil yang menggunakan reagen B (pemutih pakaian), sehingga cairan pemutih pakaian layak digunakan sebagai reagen dalam pengujian amonia pada air limbah. Hal ini juga diyakinkan dengan nilai presisi dan akurasi yang diperoleh pada pengujian dengan reagen B menyatakan hasil yang memenuhi persyaratan.
EVALUASI AKURASI DAN PRESISI RESONATOR HELHOLTZ PADA LABORATORIUM FISIKA UIN SUNAN KALIJAGA Frida Agung Rakhmadi; Dyah Imas Cholidina; Ayu Sakila Arum; Defanny Defanny; Cindy Septiani S; Ade Kurniawan; Agung Nugroho
Integrated Lab Journal Vol. 8 No. 1 (2020)
Publisher : UIN Sunan Kalijaga Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14421/ilj.2020.080105

Abstract

Research on the accuracy and precision of the Helmholtz resonator evaluation at UIN Sunan Kalijaga physics laboratory has been conducted. This research is motivated by the absence of evaluation research on this tool since its arrival in 2008. This research was conducted in 3 stages, namely the preparation of tools and materials, data collection, and data processing. The results of this study provide information that the accuracy of the Helmholtz resonator in the UIN Sunan Kalijaga physics laboratory has decreased. The accuracy is still in the good category, even though it is under SNI and SI. While the precision is still very good and still meets SNI and SI.
Aplikasi Edible Film Pati Singkong Dengan Penambahan Ekstrak Lidah Buaya (Aloe Vera) Pada Cabai Rawit (Capisum Frutascens L.) Mei Dian Syaputra; Endaruji Sedyadi; Imelda Fajriati; Sudarlin Sudarlin
Integrated Lab Journal Vol. 8 No. 1 (2020)
Publisher : UIN Sunan Kalijaga Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14421/ilj.2020.080101

Abstract

Penelitian tentang edible film menggunakan bahan dasar pati singkong dengan penambahan ekstrak lidah buaya dan sorbitol sebagai plasticizer telah dilakukan. Tujuan dari penelitian ini untuk memahami pengaruh penambahan ekstrak lidah buaya terhadap sifat mekanik edible film danpengaruh pelapisan edible film terhadap masa simpan cabai rawit (Capsicum frutescens L.) berdasarkan uji susut bobot dan uji tekstur. Penelitian ini dilakukan dengan 4 tahapan kerja yaitu, pembuatan ekstrak lidah buaya, pembuatan edible film, uji sifat mekanik yang meliputi ketebalan, kuat tarik, elongasi, modulus elastisitas, dan aplikasi edible film pada cabai rawit. Variasi ekstrak lidah buaya yang ditambahkan sebesar 0,01; 0,03; 0,05; 0,07 dan 0,14 gram. Karakteristik gugusfungsi diuji dengan menggunakan FTIR dan uji aplikasi edible film pada cabai rawit dilakukan selama empat belas hari dengan parameter uji susut bobot dan tekstur. Sifat mekanik terbaik dihasilkan dengan ketebalan 0,0620 mm, kuat tarik 10,8342 MPa, elongasi 3,4166 %, moduluselastisitas 3,5544 MPa dan WVTR sebesar 3,8776 g/m2.24 jam. Penambahan ekstrak lidah buaya menunjukkan pengaruh yang signifikan terhadap sifat mekanik. Pelapisan edible film pada cabai rawit berpengaruh terhadap masa simpan yang dibuktikan dengan susut bobot dan uji tekstur.
Pengujian Kinerja Catu Daya DC Type 7015 Imam Saukani
Integrated Lab Journal Vol. 8 No. 1 (2020)
Publisher : UIN Sunan Kalijaga Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14421/ilj.2020.080102

Abstract

Salah satu bagian terpenting pada sebuah sistem elektronika adalah bagian penyedia tegangan dan arus listrik. Karena sebuah sistem elektronika tidak akan dapat berfungsi apabila belum dicatu oleh suatu sumber tegangan atau arus listrik. Oleh karenanya diperlukan peralatan yang mampu menyediakan dan mengalirkan tegangan dan arus listrik. Peralatan ini disebut catu daya atau power supply. Penelitian ini bertujuan untuk mengetahui pengaruh tegangan dan arus pada output catu daya DC TYPE 7015 terhadap perubahan dari beban resistif, sehingga dapat diketahui batas kemampuan sebuah catu daya, sekaligus untuk mengetahui keakuratannya. Setelah diketahui tingkat kehandalan/keakuratannya diperoleh juga informasi rekomendasi untuk dilakukan perawatan bila memang diperlukan. Kegiatan-kegiatan seperti praktikum, eksperimen ataupun penelitian di laboratorium umumnya juga menggunakan catu daya sebagai sumber tegangan dan arus listrik. Selain jenisnya beragam, kebutuhan tegangan dan arus listrik yang akan digunakan pada tiap-tiap rangkaian elektronika berbeda-beda pula. Untuk memenuhi kebutuhan ini dilaboratorium tempat kami bertugas telah menyediakan catu daya jenis teregulasi linier tipe simetris variabel dengan dilengkapi sistem pendeteksi drop tegangan.Berdasarkan hasil analisa terhadap data penelitian, maka dapat diketahui bahwa pada kondisi belum ada beban ( R = 0Ω ) sebagian besar dari catu daya menunjukkan adanya selisih pembacaan antara tegangan pada alat ukur (Vm) dan tegangan pada display catu daya (Vd), selisih tegangan (ΔV) ini bernilai pada kisaran 0.06V sampai 0.55V hal ini menunjukkan menurunnya kondisi kinerja pada catu daya.