cover
Contact Name
Harry Budiman
Contact Email
harry@bsn.go.id
Phone
+6285718217895
Journal Mail Official
harry@bsn.go.id
Editorial Address
Kawasan Sains dan Teknologi BJ Habibie BRIN Serpong Tangerang 15314 Building 420
Location
Kota adm. jakarta pusat,
Dki jakarta
INDONESIA
Jurnal Instrumentasi
ISSN : 01259202     EISSN : 24601462     DOI : 10.31153
The scientific areas covered by Instrumentasi are those backboned by scientific measurements and thus range from instrument engineering, metrology, testing, and control. All papers submitted are refereed by bona fide reviewers from leading research institutions as well as universities prior to publication to keep their quality meet the standard of the journal. The review is carried out mainly on the basis of originality, novelty, and contribution to scientific measurement. Authors need to complete the ethical clearance form for publication.
Articles 7 Documents
Search results for , issue "Vol 42, No 1 (2018)" : 7 Documents clear
AN EXAMPLARY EMBODIMENT FOR A METHOD TO OBTAIN RAINFALL INFORMATION USING 48 SENSORS OF A RAINROSE INSTRUMENT Sensus Wijonarko
Instrumentasi Vol 42, No 1 (2018)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/instrumentasi.v42i1.116

Abstract

The purpose of this study was to show an application for a technique to gain rainfall information utilizing 48 sensors of a rainrose instrument. An analytic descriptive was employed as the study method. Even though the way to get the output was relatively complex, the result was not easy to be achieved using the available raingauges on the market.
IMPROVING CALIBRATION AND MEASUREMENT CAPABILITY (CMC) OF PSYCHROMETER CALIBRATION Arfan Sindhu Tistomo; Purwowibowo -; Rcahman Soleh; Melati Azizka Fajria; Ocka Hedrony
Instrumentasi Vol 42, No 1 (2018)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/instrumentasi.v42i1.86

Abstract

The improvement of Calibration Measurement Capability (CMC) for Psychrometer calibration has been done through calibrating a homemade psychrometer with two platinum resistance sensors as its  dry and wet bulb thermometers. The calibration range covers 15 %rh to 90 %rh in a temperature range from  25 °C to 65 °C. The uncertainty budget is evaluated from the individual quantity uncertainty following Ferrel equation. As results, not only the existing CMC is greatly improved from 5 %rh to 1.8 %rh but also the calibration uncertainty at each set point is in accordance to the review criteria uncertainty values for submitting relative humidity CMCs to the Appendix C of Bureau International des Poids et Mesures (BIPM).
Peer Reviewers Acknowledgement Instrumentasi Instrumentasi
Instrumentasi Vol 42, No 1 (2018)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/instrumentasi.v42i1.186

Abstract

Peer Reviewers Acknowledgement
OPTIMASI PENALAAN KONTROLER PID PADA INSTALASI PENGOLAHAN AIR GAMBUT Sutrisno Salomo Hutagalung
Instrumentasi Vol 42, No 1 (2018)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/instrumentasi.v42i1.98

Abstract

Optimasi penalaan parameter kontroler PID selalu didasarkan terhadap karakteristik suatu proses plant, maka dari itu perilaku plant harus diketahui terlebih dahulu sebelum optimasi penalaan parameter PID dilakukan. Karena penyusunan model matematik plant itu tidak mudah, maka dikembangkan suatu metoda eksperimental yaitudimana variabel proses yang diukur merespon secara terus menerus untuk mengubah sinyal keluaran kontroler yang mana fundamental dalam desain dan penalaan parameter kontroler PID. Parameter kontroleryang model dinamis tidak hanya digunakan dalam korelasi untuk menghitung nilai penalaan, tetapi juga memberikan pengetahuan yang dalampadadesainparameter seperti kontrol lup, waktu sampling dan keadaan waktu mati dalam kinerja unjuk kerja. Optimasi proses dilakukan dengan membandingkan penalaankontroler menggunakan metode Ziegler-Nichols untukkurva reaksi proses dan osilasi serta metode Cohen-Coon. Metode ini dibandingkan berdasarkan unjuk kinerja. Optimasi penalaan parameter kontrolerPID dengan metode kurva reaksi proses pada sistem kontrol level untuk pengolahan air gambut menjadi air bersih diperoleh data optimasi penalaan, untuk P = 132%, I = 9,140 menit, D = 2,285 menit, Ts = 60, yang menunjukkan desain dapat direkomendasikan.
PENINGKATAN KEMAMPUAN KALIBRASI STOPWATCH -TIMER DIGITAL 3 DIGIT DI PUSLIT METROLOGI-LIPI MELALUI METODE TOTALIZED Hapiddin, Asep; Boynawan, A. M.; -, Ratnaningsih; Pawestri, Yulita Ika; Agmal, Swivano
Instrumentasi Vol 42, No 1 (2018)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/instrumentasi.v42i1.124

Abstract

RCM-LIPI capability in the field of stopwatch-timer calibration has improved through totalized method. In this study, we compared the measurement results using the direct comparison method and the totalized method, using the same unit under test (UUT) which is the Casio 401Q21R digital stopwatch with 10-3 resolution and also with the same measuring point. Measurements in both direct and totalized calibration methods were performed with five data retrievals for each measuring point, i.e. 10 s, 20 s, 30 s, 40 s, 50 s and 60 s. The value of the measurement uncertainty has been successfully improved one order of magnitude. As a result, the human reaction time standard deviation, HRTSD: uHRTSD has significant influence to the combined uncertainty. The result of calculation of uHRTSD in calibration system using totalized method is better than calibration system using direct comparison method.
PETA KEKUATAN PENGUKURAN BERSKALA NANO DI INDONESIA Darmayanti, Nur Tjahyo Eka; Rahman, Ardi; Nugraha, Asep Ridwan
Instrumentasi Vol 42, No 1 (2018)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/instrumentasi.v42i1.101

Abstract

Perkembangan nanoteknologi di dunia terus bergerak maju. Di Indonesia, perkembangan nanoteknologi berjalan lambat dan aplikasinya belum sebanyak negara-negara maju. Aplikasi nanoteknologi baru difokuskan pada pertanian, bahan maju, farmasi dan energi. Tak pelak lagi untuk mendorong nanoteknologi agar berkembang pesat adalah dibutuhkannya penerapan ilmu pengukuran pada skala nano yaitu dengan nanometrologi. Nanometrologi berperan dalam penjaminan keabsahan hasil pengukuran melalui suatu ketertelusuran pengukuran. Nanometrologi dapat diterapkan dengan baik apabila kebutuhan nasional terhadap ketertelusuran pengukuran berskala nano dapat diketahui dan dipetakan. Makalah ini membahas pemetaan potensi dan kebutuhan ketertelusuran pengukuran berskala nano di Indonesia. Selain itu, makalah ini juga mengidentifikasikan permasalahan-permasalahan yang timbul ketika nanometrologi diterapkan. Data diperoleh melalui survey dengan menyebarkan kuisioner ke berbagai lembaga riset dan perguruan tinggi yang telah diketahui memiliki alat-alat ukur objek berskala nano. Hasil penelitian menunjukkan bahwa kebutuhan terbesar terhadap ketertelusuran pengukuran adalah untuk alat ukur Scanning Electron Microscope (SEM) dan Brunauer, Emmett and Teller (BET) dengan persentase 19%. Dengan adanya penelitian ini maka diharapkan nanometrologi dapat diterapkan secara baik dan dapat turut mempercepat perkembangan nanoteknologi serta mampu menyelesaikan permasalahan ketertelusuran di Indonesia. 
MENYOAL URGENSI UJI PROFISIENSI NANOMETROLOGI DIMENSI DI INDONESIA Nur Tjahyo Eka Darmayanti; Asep Ridwan Nugraha; Diina Qiyaman; Ardi Rahman
Instrumentasi Vol 42, No 1 (2018)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/instrumentasi.v42i1.104

Abstract

Nanoteknologi dan nanometrologi adalah dua bidang keilmuan yang tidak bisa dipisahkan. Perkembangan pesat pada penelitian yang menghasilkan produk nanoteknologi tentunya membutuhkan nanometrologi untuk menjamin kontrol kualitasnya. Tren pengembangan nanoteknologi saat ini terus naik baik di dunia maupun di Indonesia. Indonesia sebagai negara dengan potensi pasar yang besar, memiliki bahan baku untuk memproduksi material nano. Hal ini menjadikan Indonesia memiliki posisi yang diperhitungkan di dunia. Puslit Metrologi LIPI sebagai lembaga metrologi nasional memiliki peran untuk mengembangkan ketertelusuran nanometrologi di Indonesia. Di dalam makalah ini dibahas mengenai pentingnya uji profisiensi pada bidang nanometrologi. Uji profisiensi dilakukan mengacu pada uji banding yang dilakukan negara - negara yang tergabung dalam BIPM, terdiri dari berbagai jenis artefak, yaitu: line width standards, step height standards, line scales, 1D gratings, 2D grating dan nano particle. Di Indonesia, kelompok penelitian nanometrologi dari Puslit Metrologi LIPI menyelenggarakan uji banding untuk menguji validitas alat ukur nano yang digunakan di institusi penelitian. Berdasarkan hasil penelitian sebelumnya, uji banding dilakukan pada alat ukur SEM yang paling banyak digunakan, dan penjaminan ketertelusuran nanometrologi dilakukan dalam bidang dimensi. Uji banding dirancang mengacu pada pengujian yang dilakukan Working Group CCL Nano4.

Page 1 of 1 | Total Record : 7