Jurnal Instrumentasi
ISSN : 01259202     EISSN : 24601462     DOI : 10.31153
The scientific areas covered by Instrumentasi are those backboned by scientific measurements and thus range from instrument engineering, metrology, testing, and control. All papers submitted are refereed by bona fide reviewers from leading research institutions as well as universities prior to publication to keep their quality meet the standard of the journal. The review is carried out mainly on the basis of originality, novelty, and contribution to scientific measurement. Authors need to complete the ethical clearance form for publication.
Articles 10 Documents
Search results for , issue "Vol 45, No 2 (2021)" : 10 Documents clear
Degradation Characteristics of Wastewater Containing 2-Chlorophenol and 4-Chlorophenol Compounds, Using a Dielectric Barrier Discharge (DBD) Cold Plasma Reactor Luvita, Veny; Sugiarto, Anto Tri; Bismo, Setijo
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.257

Abstract

Wastes containing phenolic compounds, including 2-chlorophenol and 4-chlorophenol at a threshold exceeding 50 mg / L, are very harmful to the environment. The processing of waste containing phenolic compounds using ozone and plasma technology is therefore an environmentally friendly and relatively inexpensive solution. The processing carried out in this study uses ozone plasma technology. Plasma is generated by high voltage transformator which is fed into electrodes wound on a reactor made of quartz glass. The reactor type is dielectric barrier discharge (DBD) have the ability to degrade these waste, by producing reactive oxygen species, including •OH, •O2- and molecular species of O3, H2O2. Subsequently, active species with high energy are transferred to the liquid phase, to react with chlorophenol compounds. According to the results, the dielectric barrier discharge plasma reactor using electrode coils was able to degrade waste containing 2-chlorophenol compounds by 70.96% and 79.41%, in acidic and alkaline conditions, respectively, while, 4-chlorophenol was degraded by 23.42% and 53.54%, in acidic and alkaline conditions, respectively.
UNCERTAINTY EVALUATION OF SMART CARDIO DEVICE Insani, Asep; Khusni, Uus; Sugiarto, Anto Tri
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.282

Abstract

Electrocardiograph (ECG) is a device used to measure electrical activity from the heart. The existence of abnormalities in the heart, it requires a tool to detect the symptoms of the disorder earlier so that a Smart Cardio Device is made with an intelligent system. This intelligent system is used to detect ECG output signals and separate them from normal ones with those with disease disorders. In determining the validity of the ECG signal that is released by the tool made, a standard system is needed to justify the signal. Of course, it takes experts who are competent in their field to determine this. This research collaborates with one of the calibration labs made by the National Standardization Agency (BSN) with calibration researchers who are experts in the ECG field who are developing a method specifically for calibrating ECG signals. The general calibration method used is the internal calibration method with calibration features on ECG devices and external calibration with the help of patient simulator. In this study external calibration methods were used, namely methods that take into account the validity or validity of measurements by looking at the value of uncertainty. The thing that is done in determining this uncertainty is the calculation of values by making several measurements to get the value of the degree of effective freedom and an expanded uncertainty value. The result shows the value of the effective degree of freedom is 93, 91 mV and the uncertainty value that is extended is 0.058 mV.
PENERAPAN LABORATORY INFORMATION MANAGEMENT SYSTEM (LIMS) DI SNSU-BSN SESUAI DENGAN ISO/IEC 17025:2017 Muhammad Azzumar; Muhammad Haekal Habibie
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.285

Abstract

Telah dilakukan penelitian mengenai perancangan Laboratory Information Management System (LIMS) di SNSU-BSN. LIMS SNSU-BSN merupakan suatu sistem untuk menyimpan dan mengendalikan data dan informasi dalam bentuk digital yang dirancang sesuai dengan standar ISO/IEC 17025:2017. LIMS SNSU-BSN digunakan sebagai back-up dari data dan informasi, penelusuran jejak digital dari data dan informasi, dan pengelolaan data dan informasi yang lebih efisien, efektif dan murah.  Platform LIMS SNSU-BSN dibangun dengan menggunakan aplikasi open source Owncloud 7.0 dan beberapa environment system yang sesuai. Sistem untuk mengidentifikasi akun pada LIMS SNSU-BSN terdiri atas 2 tahapan berdasarkan database sistem dan tingkat akses data. Selain itu untuk meningkatkan keamanan dari data dan informasi, operasional server dan hosting dikelola oleh internal BSN dan hanya dapat diakses dengan menggunakan jaringan BSN. Hasilnya adalah LIMS SNSU-BSN telah berhasil dibangun dan diimplementasikan sehingga dapat digunakan sebagai sarana storage dari seluruh data dan informasi di SNSU-BSN. Selain itu LIMS SNSU-BSN telah digunakan untuk mendukung implementasi dari ISO/IEC 17025:2017 seperti audit internal, kaji ulang manajemen, kaji ulang permintaan, dll.
cover instrumentasi instrumentasi instrumentasi
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.286

Abstract

cover
DEVELOPMENT OF OFFICIAL INDONESIA STANDARD TIME : TEMPERATURE CONTROL SYSTEM FOR CAESIUM ATOMIC CLOCK Windi Kurnia Perangin-Angin; Mohamad Boynawan; Ratnaningsih Ratnaningsih
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.242

Abstract

Every country should have an official time standard which called local coordinated universal time, UTC(k). Badan Standardisasi Nasional (BSN) has developed an official standard time, namely UTC(IDN) which is used as Indonesia Standard Time. The UTC(IDN) contributes to calculation of coordinated universal time (UTC). In order to generate the UTC(IDN), the output of 1 pulse per second signal of caesium atomic clock is utilized as the actual signals of this standard. A distribution amplifier is used to distribute the signal. Combination of time transfer system (TTS-3) and GPS are employed for comparison of UTC and UTC(IDN). TTS-3 automatically calculated the difference and it is steered by using certain algorithm. Time synchronization to the standard can be conducted through network time protocol (NTP) server, i.e., ntp.bsn.go.id. The time can be automatically synchronized using internet time or certain program at each computer or machine. The results of this work show that the time differences between UTC – UTC(IDN) vary from 43.2 ns to 1729.9 ns. UTC(IDN) has frequency and time stability of 3.6 x 10-14 Hz/Hz per 5 days and 3.1 ns per 5 days, respectively which are in good agreement to the international time reference. A shielding chamber with temperature control system has been built to keep the ambient temperature of caesium atomic clock at (23 ± 1) ᵒC. It can be concluded that BSN has been developing and disseminating the UTC(IDN) as an Indonesia Standard Time that can support the regulation of time synchronization in Indonesia. A new temperature control system is proposed to stabilize the ambient temperature of caesium atomic clock. The temperature control system supports an accurate and stable UTC(IDN).
INDUCTANCE VALIDATION OF LCR METER AFTER RECALIBRATION Lukluk Khairiyati; Muhammad Azzumar; Miftahul Munir; Mohamad Syahadi
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.258

Abstract

Laboratory of National Measurement Standard for Electricity and Time (NMS ET Lab) has validated the measurement results pre and post the LCR meter recalibration process on inductance parameters. The validation process was carried out at nominal values of 100 μH, 1 mH, 10 mH, 100 mH and 1 H in accordance to the reference standards. The direct measurement method was used to measure the inductance parameter of LCR meter with standard inductor. Validation is carried out by comparing the measurement results pre and post the LCR meter recalibration process at SCL - Hong Kong. Based on the En number analysis, the values between -0.21 to 0.44 were obtained for 5 measurement points, therefore the calibration system and method used by NMS ET Lab are valid and have measurement results that are equivalent to other countries.
VALIDASI METODE PENGUJIAN KLORIDA PADA URANIUM DIOKSIDA DENGAN METODE TIDAK LANGSUNG MENGGUNAKAN SPEKTROFOTOMETER SERAPAN ATOM Fikri Ahmad Furqan; Deni Mustika; Rahmiati Rahmiati; Torowati Torowati; Asminar Asminar
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.235

Abstract

Metode tidak langsung pengujian klorida dilakukan dengan mereaksikan klorida dengan perak berlebih, kemudian kadar perak sisa yang tidak bereaksi dihitung. Penelitian ini bertujuan untuk mengetahui kelayakan suatu metode melalui beberapa parameter, seperti linieritas, akurasi dan presisi, limit kuantitasi, dan limit deteksi instrumen pada sampel tanpa matriks (A), sampel UO2 dengan penambahan larutan standar Cl setelah ekstraksi (B) dan sampel UO2 dengan penambahan larutan standar Cl sebelum ekstraksi (C). Diperoleh nilai regresi linier pada sampel A sebesar 0,997, pada sampel B sebesar 0,996, dan pada sampel C sebesar 0,995. Nilai recovery yang didapat pada sampel A sebesar 102,804 %, pada sampel B sebesar 98,924 %, dan pada sampel C sebesar 98,096 %. Nilai simpangan baku relatif yang didapatkan pada sampel A sebesar 1,4 %, pada sampel C sebesar 0,2 %, dan pada sampel B sebesar 0,5 %. Nilai limit deteksi pada sampel dengan matriks yang didapat dengan metode ini, yaitu 0,0958 µg/g dan 0,1024 µg/g, sedangkan nilai limit kuantitasi pada sampel dengan matriks yaitu 0,3195 µg/g dan 0,3415 µg/g. Berdasarkan hasil penelitian, dapat dinyatakan bahwa metode tervalidasi dan layak diterapkan di Laboratorium Kendali Kualitas – Instalasi Elemen Bakar Eksperimental.
STUDI RANDOM ERROR PADA PENGUKURAN MIKROTREMOR SERTA IMPLIKASINYA TERHADAP PERHITUNGAN Vs30 DAN KETEBALAN SEDIMEN Ashar Muda Lubis; Muttaqin Muttaqin; Rida Samdara
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.255

Abstract

Telah dilakukan penelitian random error pada pengukuran mikrotremor dengan peralatan PASI MOD GEMINI 2 SN-1405. Pada penelitian ini juga dikaji implikasi perbedaan hasil perhitungan frekuensi dominan () dan amplifikasi situs () pada pengukuran mikrotremor terhadap kecepatan rata-rata gelombang geser hingga kedalaman 30 m (Vs30) dan ketebalan sedimen (h ) untuk pengklasifikasian jenis tanah. Pengambilan selama 2018-2019 telah dilakukan untuk memperoleh 100 hari data mikrotremor dengan durasi selama 30 menit di Kota Bengkulu. Kurva-kurva H/V telah dianalis untuk mendapatkan nilai-nilai dan . Pada penelitian ini diperoleh ketelitian pengukuran yang sangat baik untuk dan  dengan persentase kesalahan pengukuran <1%. Secara statistik, nilai-nilai dan yang diperoleh mememuhi fungsi distribusi normal. Hasil penelitian ini memiliki implikasi dan dampak terhadap estimasi nilai Vs30 dan h dimana meskipun pengambilan data dilakukan pada tempat yang sama dengan kondisi geologi yang juga sama, akan tetapi memberikan variasi yang signifikan terhadap nilai Vs30 karena pengaruh range nilai dan . Sebagai akibatnya perkiraan klasifikasi tanah pada suatu tempat yang sama didaptkan berbeda. Kedepan pengukuran mikrotremor untuk suatu stasiun memerlukan pengukuran yang berulang sehingga interpretasi klasifikasi tanah didapatkan lebih tepat dan akurat karena dapat mengungkap hasil yang sebenarnya.
MEASUREMENT UNCERTAINTY OF WINDING TEMPERATURE RISE ON WASHING MACHINE HEATING-TEST Himma Firdaus; Nanang Kusnandar
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.239

Abstract

Evaluation of measurement uncertainty in safety tests is critical for a testing laboratory, especially if many aspects influence the test results, such as in the washing machine heating test. While performing the heating test, the temperature rise of the motor winding was determined to evaluate the safety level of a washing machine. The temperature rise is obtained by the resistance method, which measures the change of winding resistance to assess its temperature rise. In this work, the washing machine was loaded at maximum capacity and supplied with hot water. All factors contributing to the measurement uncertainty originating from both the measurement system and the testing method are evaluated. The expanded uncertainty of the temperature rise measurement obtained in this study is 1.4%.  This uncertainty is mainly contributed by the variance of test water temperature (0.54%), calibration uncertainty of RCL meter (0.43%), and calibration uncertainty of temperature logging system (DLS) (0.31%). Therefore, the heating test requires a tight temperature controller, an improved calibration uncertainty of the resistance meter, and a better accuracy of the temperature logger to reduce the measurement uncertainty.
SIMULASI PENGARUH PERUBAHAN LAJU ALIRAN AIR TERHADAP TINGGI MUKA AIR PADA SISTEM PENGENDALIAN TINGGI MUKA AIR MENGGUNAKAN KONTROLER PID STUDI KASUS: SIMULATOR UNTUK PENGUKURAN DAN PENGENDALIAN PROSES DI INDUSTRI DAN SCADA. Iwan Rohman Setiawan
Instrumentasi Vol 45, No 2 (2021)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v45i2.259

Abstract

Menyelidiki pengaruh perubahan laju aliran air terhadap tinggi muka air di dalam tangki, pada sistem pengendalian tinggi muka air di dalam tangki menggunakan kontroler PID-single loop dan sistem pengendalian bertingkat. Percobaan dilakukan  melalui simulasi menggunakan Simulink, dengan terlebih dahulu membuat pemodelan untuk setiap komponen yang digunakan pada simulator. Set point tinggi muka air di dalam tangki 0,3 m. Ketika tinggi muka air dalam keadaan steady, menaikan laju aliran air mulai dari 5x10-5 m3/detik sampai dengan 1x10-4 m3/detik. Selanjutnya menurunkan laju aliran mulai dari -6,6667x10-5 m3/detik sampai dengan -1,1667x10-4 m3/detik. Akibat kenaikan laju aliran air  pada sistem pengendalian tinggi muka air-sistem pengendalian bertingkat, tidak mempengaruhi tinggi muka air di dalam tangki. Sedangkan pada sistem pengendalian tinggi muka air di dalam tangki-single loop, mengakibatkan tinggi muka air mengalami kenaikan, walaupun tinggi muka air di dalam tangki kembali ke set point yaitu 0,3 m. Begitu juga ketika laju aliran yang menuju tangki diturunkan mulai dari 5x10-5 m3/detik sampai dengan -8,3333x10-4 m3/detik, tidak mempengaruhi tinggi muka air di dalam tangki pada sistem pengendalian-single loop dan sistem pengendalian bertingkat. Ketika laju aliran diturunkan mulai dari -1x10-4 m3/detik, maka tinggi muka air berkurang dan tidak dapat mencapai set point kembali.